ConTour Array™ 1.4

Depending on application, use two or three  
ConTour Array™ subwoofers as the stack‘s base. 
Set the desired number of subwoofers on top of
one another. 

Caution: 
Secure the ground stack to prevent it from tipping! 
Use the M10 bushings on the back of the CTA 118 
subwoofer and the ground-stack connectors to do 
this.

Mount mid/high units individually, one after 
another, on the top CTA 118 Sub. Use the ConTour 
Array™ stack plate as the base and connector to 
the subwoofer. Attach it to the CTA 118 Sub’s pole 
mount using the M20 thumb screw. The stack plate 
lets you easily adjust mid/high units without having 
to move the subwoofer. On this stack plate, you can 
freely select the desired down-tilt between 0° and 9° 
in 1.5° increments.

Fig. 12 a, b: ConTour Array™ ground stack connectors

Fig. 13: ConTour Array™ stack plate

Fig. 14 a, b: Attaching the stackplate to the CTA 118 Sub

2. Ground stacking

3.  Mains and Generator 

Power Supply

Connect no more than two CTA 118 Subs to one 
mains phase (16 A). If you use the Powercon 
Link port, connect no more than one further CTA 118 
Sub. The 13 A limit on maximum input current 
(see label) applies to Great Britain because UK 
power cables are approved to 13 A only. 16 A 
current is permissible in other countries using EU 
power cables.

Caution: If you must power the CTA 118 Sub with 
a generator, ensure the generator is running before 
you switch the system on. Never switch systems 
off and on with the help of the generator! This 
can damage the PWM power amps’ switching 
power supply!

Note: The Powercon Link is not available for 
100-120-volt units.

Fig. 15 a,b,c: CTA 208 Mid/High stack

Содержание CONTOUR ARRAY

Страница 1: ...1 Manual 1 4 ConTour Array English Deutsch Français ...

Страница 2: ...al other power consumers The plug socket for the power supply must be positioned near the unit and must be easily accessible PLACE OF INSTALLATION The unit should stand only on a clean horizontal working surface The unit must not be exposed to vibrations during operation Place the product always in a way that the mains switch is easily accessible Keep away from moisture and dust where possible Do ...

Страница 3: ...r 15 1 The DDO Pro Net Port 15 2 Audio Signal Routing 15 3 Handling the DDO Pro Controller 15 3 1 Level 15 3 2 Key Lock 15 3 3 Utilities 15 3 4 Sub Delay 16 3 5 Delay 16 3 6 Sub Level 16 3 7 System Setup 16 3 8 Quick Guide to the V1 01 Controller s Menu Structure 17 4 Technical Specifications DDO Pro Controller 18 E Service 19 1 Maintenance 19 2 ConTour Array Spare Parts 19 3 Replacing Loudspeaker...

Страница 4: ...dislodge stuck or immovable loads lift people strike knock or dent rigging frames heat treat or weld rigging frames exceed the truss s maximum load carrying capacity Note that in addition to the above specifications the operational safety regulations of VBG 9 accident prevention regulations of the German employers liability insurance association apply HK AUDIO is not responsible for damages caused...

Страница 5: ...ment to be inspected at least yearly for cracks Inspect equipment used in dynamic applications for cracks every six months Maintenance You may replace easily serviceable wearing or standard parts according to the manufacturer s instructions Use original replacement parts only Tighten screws and bolted connections whenever necessary Repair If parts of the load bearing equipment become deformed it i...

Страница 6: ...laration of conformity of the European Communities is the result of an examination carried out by the Quality Assurance Department of STAMER GmbH in accordance with European Standards EN 50081 1 EN 50082 1 and EN 60065 for low voltage as laid down in Article 10 of the EMC Directive Magdeburger Str 8 66606 St Wendel Lothar Stamer Dipl Ing Managing Director St Wendel 02 08 06 To the best of our know...

Страница 7: ...s are out of harm s way on a recessed connector panel on the CTA 208 s back It offers two Speakon NL 4 connectors Pin assignments are pin 1 mid high 1 mid high Caution Please connect just one CT 208 to each CTA 118 Sub enclosure The second port serves to connect a power amp in parallel up to two CTA 208 at 4 ohms 1 1 Specifications CTA 208 A professional two way system featuring cylindrical wave t...

Страница 8: ... frequency driver 4x 1 2 voice coil Crossover frequency 2 kHz 12 dB octave Connectors 2x Speakon NL 4 Housing birch 15 18 mm 1 2 9 13 ply Angles up 2x 4 5 Finish Black 2 component PU lacquer Grille Metal grille with black acoustic foam Handles Two slot grips routed into the side panels Rigging hardware DualCurve integrated with quick release pins Pole mount HK AUDIO DuoTilt Weight 29 kg 63 8 lbs D...

Страница 9: ...rm s way on a recessed connector panel on the CTA 118 Sub s back It offers two Speakon NL 4 connectors Pin assignments are pin 1 mid high 1 mid high A Powercon mains socket with another Powercon output connects to the power supply A female XLR and a male XLR port serve to route signals Two Neutrik Ethercon ports serve to network several CTA 118 Subs 2 1 Specifications CTA 118 Sub A professional ac...

Страница 10: ...t RS 485 Ethercon Woofer 18 Frequency response 10 dB 36 Hz fx Frequency response 3 dB 42 Hz fx Sensitivity 1W 1m 1 101 dB Max SPL calculated 1 134 dB 2 Max SPL peak 1 133 dB Max SPL 1 130 dB 10 THD 50 Hz 200Hz Housing birch 18 mm 3 4 13 ply Surface coating Black 2 component PU lacquer Grille Metal grille with black acoustic foam Handles 6 slot grips routed into the side panels 1 on the lid Pole mo...

Страница 11: ...e Roll the case off to the side Remove the two front pins from the enclosure you wish to mount and fold down its connector component Now you can rig further cabinets Tip If you intend to rig additional enclosures we recommend that you attach all the required speaker cords to the rigging frame now because this task becomes more difficult as the array grows higher Be sure to use cords of sufficient ...

Страница 12: ...13 Fig 11 a b c d e Rigging additional CTA 208 enclosures Fig 10 Hoisting the mounted CTA 208 enclosure Fig 8 Mounting the rigging frame Fig 9 Setting an intermediate angle English ...

Страница 13: ...between 0 and 9 in 1 5 increments Fig 12 a b ConTour Array ground stack connectors Fig 13 ConTour Array stack plate Fig 14 a b Attaching the stackplate to the CTA 118 Sub 2 Ground stacking 3 Mains and Generator Power Supply Connect no more than two CTA 118 Subs to one mains phase 16 A If you use the Powercon Link port connect no more than one further CTA 118 Sub The 13 A limit on maximum input cur...

Страница 14: ...the difference D The ConTour Array DDO Pro Controller Fig 16 DDO Pro network Fig 17 DDO Pro Controller panel Net Ports link several CTA 118 Subs in a communication network Use CAT 5 network cables or professional Ethercon cables with a metal plug to do this Connect the first CTA 118 Sub s output to the next unit s input and so forth Note This is purely a data interface The DDO Pro Net Port does no...

Страница 15: ...ing meters m feet ft or milliseconds ms Select the option with the Up or Down keys and confirm your selection with Enter 3 4 Sub Delay Sub Delay is a time alignment tool that is it compensates differences in mid high units and subwoofers response times Like Sub Level Sub Delay controls subwoofers and mid high units relative delay For example if you place subwoofers well in front of mid high units ...

Страница 16: ...17 Fig 19 Menu structure of the DDO PRO Controller 3 8 Quick Guide to the V1 01 Controller s Menu Structure English English ...

Страница 17: ...outputs 1 2 Sampling frequency 48 kHz Bandwidth 56 bits Frequency range 20 Hz to 20 kHz 0 5 dB Dynamic range 112 A weighted 22 kHz bandwidth Interface RS 485 Ethercon Gain 96 dB to 6 dB in 0 5 dB steps Sub Level 12 dB to 6 dB in 0 5 dB steps Delay Up to 72 ms Limiter HK AUDIO DDO Multi Band Limiter ...

Страница 18: ...ing and connecting a replacement speaker Red positive black negative Unfasten the voice coil housing s hex head bolts using a 3 mm wrench Take the lid off the voice coil housing Replace the voice coil Important note Replace the voice coil in a clean working environment only Be sure to keep dust and dirt out of the open driver If despite your precautions particles manage to get in use a strip of ad...

Страница 19: ...tfach 1509 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 international hkaudio com Technische Änderungen vorbehalten Copyright 2009 2014 Music Sales GmbH 10 2014 9840172 D 2716 ...

Отзывы: