background image

Wichtige Sicherheitshinweise!

Bitte vor Gebrauch lesen und für späteren Gebrauch 
aufbewahren!

•  Read all of these instructions!
•  Save these instructions for later use!
•  Follow all warnings and instructions marked on the product!
•  Do not use this product near water, i.e. bathtub, sink, swimming pool,  

wet basement, etc.

•  Do not place this product on an unstable cart, stand or table. The product may fall, 

causing serious damage to the product or to persons!

•  Slots and openings in the cabinet and the back or bottom are provided for ventilation; 

to ensure reliable operation of the product and to protect it from overheating, these 
openings must not be blocked or covered. This product should not be placed in a built-
in installation unless proper ventilation is  
provided.

•  This product should not be placed near a source of heat such as a stove,  

radiator, or another heat producing amplifier.

•  Use only the supplied power supply or power cord. If you are not sure of the type of 

power available, consult your dealer or local power company.

•  Do not allow anything to rest on the power cord. Do not locate this product where 

persons will walk on the cord.

•  Never break off the ground pin on the power supply cord.
•  Power supply cords should always be handled carefully. Periodically check cords for 

cuts or sign of stress, especially at the plug and the point where the cord exits the 
unit.

•  The power supply cord should be unplugged when the unit is to be unused for long 

periods of time.

•  If this product is to be mounted in an equipment rack, rear support should be  

provided.

•  This product should be used only with a cart or stand that is recommended by  

HK AUDIO®.

•  Never push objects of any kind into this product through cabinet slots as they may 

touch dangerous voltage points or short out parts that could result in risk of fire or 
electric shock. Never spill liquid of any kind on the product.

•  Do not attempt to service this product yourself, as opening or removing covers may 

expose you to dangerous voltage points or other risks. Refer all servicing to qualified 
service personnel.

•  Clean only with dry cloth.
•  Do not defeat the safety purpose of the polarized or grounding-type plug.  

A polarized plug has two blades with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide blade or the third prong are 
provided for the safety. If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

•  Place the product always in a way that the mains switch is easily accessible.
•  Unplug this product from the wall outlet and refer servicing to qualified service per-

sonnel under the following conditions:

•  When the power cord or plug is damaged or frayed.
•  If liquid has been spilled into the product.
•  If the product has been exposed to rain or water.
•  If the product does not operate normally when the operating instructions are followed.
•  If the product has been dropped or the cabinet has been damaged.
•  If the product exhibits a distinct change in performance, indicating a need of service!
•  Adjust only these controls that are covered by the operating instructions since impro-

per adjustment of other controls may result in damage and will often require extensive 
work by a qualified technician to restore the product to normal operation.

•  Exposure to extremely high noise levels may cause a permanent hearing loss. 
•  Individuals vary considerably in susceptibility to noise induced hearing loss, but nearly 

everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient 
time. The U.S. Government´s Occupational Safety and Health Administration (OSHA) 
has specified the following permissible noise level exposures:

  Duration Per Day In Hours 

Sound LeveldBA, Slow Response

    8 

 

  90

    6 

 

  92

    4 

 

  95

    3 

 

  97

    2 

 

  100

    11/2 

 

  102

    1 

 

  105

    1/2 

 

  110

    1/4  or less   

  115

•  According to OSHA, any exposure in excess of the above permissible limits could 

result in some hearing loss.

•  Ear plug protectors in the ear canals or over the ears must be worn when operating this 

amplification system in order to prevent a permanent hearing loss if exposure is in excess 
of the limits as set forth above. To ensure against potentially dangerous exposure to 
high sound pressure levels, it is recommended that all persons exposed to equipment 
capable of producing high sound pressure levels such as this amplification system be 
protected by hearing protectors while this unit is in operation.

•  Fuses: Replace with IEC 127 (5x 20 mms) type and rated fuse for best  

performance only.

TO PREVENT THE RISK OF FIRE AND SHOCK HAZARD, DO NOT EXPOSE THIS 
APPLIANCE TO MOISTURE OR RAIN. DO NOT OPEN CASE; NO USER SERVICE-ABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Version 1.1  11/2006

•  The unit has been built by HK AUDIO® in accordance with IEC 60065 and left the 

factory in safe working order. To maintain this condition and ensure non-risk opera-
tion, the user must follow the advice and warning comments found in the operating 
instructions. The unit conforms to Protection Class 1 (protectively earthed).

•  HK AUDIO® ONLY GUARANTEE THE SAFETY, RELIABILITY AND EFFICIENCY OF 

THE UNIT IF:

•  Assembly, extension, re-adjustment, modifications or repairs are carried out by  

HK AUDIO® or by persons authorized to do so.

•  The electrical installation of the relevant area complies with the requirements of IEC 

(ANSI) specifications.

•  The unit is used in accordance with the operating instructions.
•  The unit is regularly checked and tested for electrical safety by a competent technician.

  WARNING:
•  If covers are opened or sections of casing are removed, except where this can be done 

manually, live parts can become exposed.

•  If it is necessary to open the unit this must be insulated from all power sources. Please 

take this into account before carrying out adjustments, maintenance, repairs and 
before replacing parts.

•  The appliance can only be insulated from all power sources if the mains connection is 

unplugged.

•  Adjustment, maintenance and repairs carried out when the unit has been opened and is 

still live may only be performed by specialist personnel who are authorized by the manuf-
acturer (in accordance with VBG 4) and who are aware of the associated hazards.

•  Loudspeaker outputs which have the IEC 417/5036 symbol (Diagram 1, below) can 

carry voltages which are hazardous if they are made contact with. Before the unit 
is switched on, the loudspeaker should therefore only be connected using the lead 
recommended by the manufacturer.

•  Where possible, all plugs on connection cables must be screwed or locked onto the 

casing.

•  Replace fuses only with IEC127 type and specified ratings.
•  It is not permitted to use repaired fuses or to short-circuit the fuse holder.
•  Never interrupt the protective conductor connection.
•  Surfaces which are equipped with the "HOT" mark (Diagram 2, below), rear panels or 

covers with cooling slits, cooling bodies and their covers, as well as tubes and their 
covers are purposely designed to dissipate high temperatures and should therefore not 
be touched.

•  High loudspeaker levels can cause permanent hearing damage. You should  

therefore avoid the direct vicinity of loudspeakers operating at high levels.  
Wear hearing protection if continuously exposed to high levels.

  MAINS CONNECTION:
•  The unit is designed for continuous operation.
•  The set operating voltage must match the local mains supply voltage.
•  The unit is connected to the mains via the supplied power unit or power cable.
•  Power unit: Never use a damaged connection lead. Any damage must be rectified by a 

competent technician.

•  Avoid connection to the mains supply in distributor boxes together with several other 

power consumers.

•  The plug socket for the power supply must be positioned near the unit and must be 

easily accessible.

  PLACE OF INSTALLATION:
•  The unit should stand only on a clean, horizontal working surface.
•  The unit must not be exposed to vibrations during operation.
•  Place the product always in a way that the mains switch is easily accessible.
•  Keep away from moisture and dust where possible.
•  Do not place the unit near water, baths, wash basins, kitchen sinks, wet areas, swim-

ming pools or damp rooms. Do not place objects containing liquid on the unit - vases, 
glasses, bottles etc.

•  Ensure that the unit is well ventilated.
•  Any ventilation openings must never be blocked or covered. The unit must be positi-

oned at least 20 cm away from walls. The unit may only be fitted in a rack if adequate 
ventilation is ensured and if the manufacturer's installation instructions are followed.

•  Keep away from direct sunlight and the immediate vicinity of heating elements and 

radiant heaters or similar devices.

•  If the unit is suddenly moved from a cold to a warm location, condensation can form 

inside it. This must be taken into account particularly in the case of tube units. Before 
switching on, wait until the unit has reached room temperature.

•  Accessories: Do not place the unit on an unsteady trolley, stand, tripod, base or table. 

If the unit falls down, it can cause personal injury and itself become damaged. Use the unit 
only with the trolley, rack stand, tripod or base recommended by the manufacturer 
or purchased together with the unit. When setting the unit up, all the manufacturer's 
instructions must be followed and the setup accessories recommended by the manuf-
acturer must be used. Any combination of unit and stand must be moved carefully. A 
sudden stop, excessive use of force and uneven floors can cause the combination of unit 
and stand to tip over.

•  Additional equipment: Never use additional equipment which has not been 

recommended by the manufacturer as this can cause accidents.

•  To protect the unit during bad weather or when left unattended for prolonged periods, 

the mains plug should be disconnected. This prevents the unit being damaged by 
lightning and power surges in the AC mains supply.

  Diagram 1 

 

Diagram 2

•  Das Gerät wurde von HK AUDIO® gemäß IEC 60065 gebaut und hat das Werk in si-

cherheitstechnisch einwandfreiem Zustand verlassen. Um diesen Zustand zu erhalten 
und einen gefahrlosen Betrieb sicherzustellen, muss der Anwender die Hinweise und 
die Warnvermerke beachten, die in der Bedienungsanleitung enthalten sind. Das Gerät 
entspricht der Schutzklasse I (schutzgeerdet).

•  DIE SICHERHEIT, ZUVERLÄSSIGKEIT UND LEISTUNG DES GERÄTES WIRD VON  

HK AUDIO® NUR DANN GEWÄHRLEISTET, WENN:

•  Montage, Erweiterung, Neueinstellung, Änderungen oder Reparaturen von  

HK AUDIO® oder von dazu ermächtigten Personen ausgeführt werden.

•  die elektrische Installation des betreffenden Raumes den Anforderungen von IEC 

(ANSI)-Festlegungen entspricht.

•  das Gerät in Übereinstimmung mit der Gebrauchsanweisung verwendet wird.

  WARNUNG:
•  Wenn Abdeckungen geöffnet oder Gehäuseteile entfernt werden, außer wenn dies von 

Hand möglich ist, können Teile freigelegt werden, die Spannung führen.

•  Wenn ein Öffnen des Gerätes erforderlich ist, muss das Gerät von allen Spannungs-

quellen getrennt sein. Berücksichtigen Sie dies vor dem Abgleich, vor einer Wartung, 
vor einer Instandsetzung und vor einem Austausch von Teilen.

•  Ein Abgleich, eine Wartung oder eine Reparatur am geöffneten Gerät unter Spannung 

darf nur durch eine vom Hersteller autorisierte Fachkraft (nach VBG 4) geschehen, die 
mit den verbundenen Gefahren vertraut ist.

•  Lautsprecher-Ausgänge, die mit dem IEC 417/5036-Zeichen (Abb.1, s.unten) versehen 

sind können berührungsgefährliche Spannungen führen. Deshalb vor dem Einschalten 
des Gerätes Verbindung nur mit dem vom Hersteller empfohlenen Anschlusskabel 
zum Lautsprecher herstellen.

•  Alle Stecker an Verbindungskabeln müssen mit dem Gehäuse verschraubt oder verrie-

gelt sein, sofern möglich.

•  Es dürfen nur Sicherungen vom Typ IEC 127 und der angegebenen Nennstromstärke 

verwendet werden.

•  Eine Verwendung von geflickten Sicherungen oder Kurzschließen des Halters ist unzu-

lässig.

•  Niemals die Schutzleiterverbindung unterbrechen.
•  Oberflächen, die mit dem "HOT"-Zeichen (Abb.2, s.unten) versehen sind, Rückwände 

oder Abdeckungen mit Kühlschlitzen, Kühlkörper und deren Abdeckungen, sowie 
Röhren und deren Abdeckungen können im Betrieb erhöhte Temperaturen annehmen 
und sollten deshalb nicht berührt werden.

•  Hohe Lautstärkepegel können dauernde Gehörschäden verursachen. Vermeiden Sie 

deshalb die direkte Nähe von Lautsprechern, die mit hohen Pegeln betrieben werden. 
Verwenden Sie einen Gehörschutz bei dauernder Einwirkung hoher Pegel.

  NETZANSCHLUSS:
•  Das Gerät ist für Dauerbetrieb ausgelegt.
•  Die eingestellte Betriebsspannung muss mit der örtlichen Netzspannung 

übereinstimmen.

•  Der Anschluss an das Stromnetz erfolgt mit dem mitgelieferten Netzteil oder  

Netzkabel.

•  Netzteil: Eine beschädigte Anschlussleitung kann nicht ersetzt werden.  

Das Netzteil darf nicht mehr betrieben werden.

•  Vermeiden Sie einen Anschluss an das Stromnetz in Verteilerdosen zusammen mit 

vielen anderen Stromverbrauchern.

•  Die Steckdose für die Stromversorgung muss nahe am Gerät angebracht und leicht 

zugänglich sein.

  AUFSTELLUNGSORT:
•  Das Gerät sollte nur auf einer sauberen, waagerechten Arbeitsfläche stehen.
•  Das Gerät darf während des Betriebs keinen Erschütterungen ausgesetzt sein.
•  Feuchtigkeit und Staub sind nach Möglichkeit fernzuhalten.
•  Das Gerät muss immer so aufgestellt werden, dass der Netzschalter frei zugänglich ist.
•  Das Gerät darf nicht in der Nähe von Wasser, Badewanne, Waschbecken, Küchenspüle, 

Nassraum, Swimmingpool oder feuchten Räumen betrieben werden. Keine mit Flüs-
sigkeit gefüllten Gegenstände -Vase, Gläser, Flaschen etc. auf das Gerät stellen.

•  Sorgen Sie für ausreichende Belüftung der Geräte.
•  Eventuelle Ventilationsöffnungen dürfen niemals blockiert oder abgedeckt werden. 

Das Gerät muss mindestens 20 cm von Wänden entfernt aufgestellt werden. Das 
Gerät darf nur dann in ein Rack eingebaut werden, wenn für ausreichende Ventilation 
gesorgt ist und die Einbauanweisungen des Herstellers eingehalten werden.

•  Vermeiden Sie direkte Sonneneinstrahlung sowie die unmittelbare Nähe von Heizkör-

pern und Heizstrahlern oder ähnlicher Geräte.

•  Wenn das Gerät plötzlich von einem kalten an einen warmen Ort gebracht wird, kann 

sich im Geräteinnern Kondensfeuchtigkeit bilden. Dies ist insbesondere bei Röhrenge-
räten zu beachten. Vor dem Einschalten solange warten bis das Gerät Raumtempera-
tur angenommen hat.

•  Zubehör: Das Gerät nicht auf einen instabilen Wagen, Ständer, Dreifuß, Untersatz 

oder Tisch stellen. Wenn das Gerät herunterfällt, kann es Personenschäden verur-
sachen und selbst beschädigt werden. Verwenden Sie das Gerät nur mit einem vom 
Hersteller empfohlenen oder zusammen mit dem Gerät verkauften Wagen, Rack, Stän-
der, Dreifuß oder Untersatz. Bei der Aufstellung des Gerätes müssen die Anweisungen 
des Herstellers befolgt und muss das vom Hersteller empfohlene Aufstellzubehör 
verwendet werden. Eine Kombination aus Gerät und Gestell muss vorsichtigt bewegt 
werden. Plötzliches Anhalten, übermäßige Kraftanwendung und ungleichmäßige 
Böden können das Umkippen der Kombination aus Gerät und Gestell bewirken.

•  Zusatzvorrichtungen: Verwenden Sie niemals Zusatzvorrichtungen, die nicht vom 

Hersteller empfohlen wurden, weil dadurch Unfälle verursacht werden können

•  Zum Schutz des Gerätes bei Gewitter oder wenn es längere Zeit nicht beaufsichtigt 

oder benutzt wird, sollte der Netzstecker gezogen werden.  
Dies verhindert Schäden am Gerät aufgrund von Blitzschlag und Spannungsstößen 
im Wechselstromnetz.

  Abb.1 

 

Abb.2

Important Safety Instructions

Before connecting, read instructions

Important Advice on Safety!

Please read before use and keep for later use!

Содержание actor dx

Страница 1: ...Manual 1 2 English Deutsch Fran ais Espa ol...

Страница 2: ...ral other power consumers The plug socket for the power supply must be positioned near the unit and must be easily accessible PLACE OF INSTALLATION The unit should stand only on a clean horizontal wor...

Страница 3: ...orcement system stands out in the crowd of far more basic active cabinets All the best from the HK AUDIO team enjoy your ACTOR DX system Warranty Register your ACTOR DX using the enclosed warranty car...

Страница 4: ...er amps crossovers and so forth to forge a homogenous system with uniform dynamics and a sonic image with sharply de ned contours DuoTilt making the most of sonic energy The novel DuoTilt pole mount a...

Страница 5: ...5 Sub A subwoofers and two ADX 115 Sub B subwoofers Always connect ACTOR DX starting at the top and working your way down refer to the diagram on the rear panel of ACTOR DX components This may seem un...

Страница 6: ...only for example half couplers TV spigots brackets and so forth Ensure wall and pole mounts are designed to handle the load an ACTOR ADX 112 A weighs 30 kg 3 6 Using the ACTOR DX Tilt Unit Using the...

Страница 7: ...TOR DX as well as all signal cables routed to the mixing console for damage see also Tips and Tricks 5 Input Sensitivity This selector matches the preamp s input sensitivity to the mixer s output sign...

Страница 8: ...it s respective volumes are matched ensuring bass and mid high ranges are rendered in balanced musical proportion If desired twist the Subwoofer Level knob to the left to decrease and to the right to...

Страница 9: ...t catch towards the cord Pin assignments are pin 1 pin 1 Feel free to use a four core cable if you wish though pin 2 and 2 remain unused of course 4 3 ACTOR ADX 115 Sub B 6 Sub B In Connecting cords C...

Страница 10: ...keyboard CD player etc are on 3 Are the Gain knobs turned up 4 Check the speaker cords for damage 5 Check if the Speakon connectors are locked twisted to the right An electrical connection is establis...

Страница 11: ...nd Limiter Subsonic Filter Midrange speaker 12 Tweeter driver 1 4 Directivity 60 x 40 CD horn Crossover frequency 950 Hz 12 dB octave Pole mount HK AUDIO DuoTilt 36 mm 7 5 15 Rigging points 4 M10 thre...

Страница 12: ...o 35 C Internal fuses T8A ACTOR ADX 115 Sub B Connections 1x Speakon Input Nominal power handling 500 W RMS 8 ohms Frequency response 3dB 1 48 Hz 130 Hz Axial sensitivity t 1W 1m 104 dB Maximum SPL 1m...

Страница 13: ...09 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 international hkaudio com Technische nderungen vorbehalten Copyright 2008 Music Sales GmbH 02 2...

Отзывы: