16
MM06UE01-2002
5.2 Assembling the moved load
Steps to assemble the moved load:
Clean the mounting surface on the linear motor system that is to receive the load.
Clean the mounting surface of the load.
Position the load over the corresponding mounting holes on the mounting surface (see Technical Information
and Approval Drawing).
Place the mounting bolts in the mounting holes and tighten them in a spiral motion from inside to outside with a
torque screws (See Table 5.1).
Check the free movement of the load over the entire travel distance.
After assembling the moved load, please design another transportation safety device to lock the forcer
housing in place during transport.
5.3 Electrical connection
DANGER!
Danger from electrical voltage!
If linear motors are incorrectly earthed, there is a danger of electric shock.
Before connecting the electrical power supply, ensure that the linear motor system is correctly
earthed.
DANGER!
Danger from electrical voltage!
Electrical currents may flow even if the motor is not moving.
Ensure that the linear motor system is disconnected from the power supply before the electrical
connections are detached from the motors.
After disconnecting the drive amplifier from the power supply, wait at least 5 minutes before
touching live parts or breaking connections.
For safety reasons, measure the voltage in the intermediate circuit and wait until it has fallen
below 40V.
Observe the separate assembly instructions of the drive!
The supply voltage is based on the drive. Please consult the manufacturer’s separate operating
instructions for detailed information.
●
Supplied with cabling ready for operation.
●
All necessary connections via three connectors of each axis.