Contents
Linear motor axis LMSSA
LMSSA-01-1-EN-2201-MA
Seite 25 von 44
Fig. 5.5: Electrical connection for drive type of E1
5.3.1
Connecting iron-core/ironless motors
The temperature sensor system cable is routed as standard through the motor’s extension cable. Both cables are
therefore connected to the motor plug.
Note:
Observe the Technical Information and Approval Drawing for pin assignment!
5.3.2
Connecting the linear positioning measurement system
Attention! Danger of EMC interference in the encoder signal!
Approved ESD precautions must be followed at all times during readhead and interface electrical
connections.
Make sure that the encoder cable has been shielded correctly!
Ensure that the shielding is in full contact across the connectors!
Ensure that the pairs of wires with the sin/cos signal are shielded separately!
Attention! Danger of injury!
An incorrectly connected distance measuring system may cause uncontrolled carriage movements which can
lead to injuries or might damage the linear axis.
Only qualified personnel may connect the distance measuring system!
The linear positioning measurement system is installed ready for operation in the linear motor system.