5
6.3 Multi-range & Multi-interval
The standard version with only one range and division, but the scale can be set as multi-range or
multi-interval, refer to LF-2 parameters setting.
If it set to be multi-range or multi-interval, it will work as below:
Multi-interval: 0 – 50%F.S. with the interval as it selected (A), 50%-100%F.S. with the next interval (B),
when the weight decrease, it will change from B to A when the range change from above 50%F.S. to less
50%F.S.
Multi-range: 0 – 50%F.S. with the interval as it selected (A), 50%-100%F.S. with the next interval (B), if the
weight decrease from above 50%F.S., it will use interval B until the scale is empty.
7. Parameters Configuration
To access the configuration of the parameters, the scale must be in zero condition, and press the
[FN]
key
to enter and press it again to select the setting from UF-1 to UF-9 (LCD version till UF-8), press
[UNIT]
key
to quit.
7.1
UF-1
Internal Counting (A/D)
When UF-1 selected, press
[ON]
key to enter it will display the A/D counting
(example: 2704565)
, Press
[ON]
again, it will display the battery voltage, press
[ON]
key again to exit this mode.
7.2
UF-2
Checkweigh Setting
When UF-2 selected, press
[ON]
key to enter, the display will show the message
000.00L
(the under
limit), use the key
[ON]
and
[FN]
to move the cursor and select the number needed, when all number
input, press
[ON]
key to confirm and the display will show the message 000.00h (the over limit), use the
key
[ON]
and
[FN]
to move the cursor and select the number needed, and when all input, press
[ON]
key to confirm, the display will show the beeping setting:
Display:
0
0
0
Corresponding:
A
B
C
A
=
0: Beep and no need to wait stabilization of the weight
=
1: The weight must be stable and then the beep can work
B
=
0: Always 0
C
=
0: Always deactivate
1: Beep during range of OK (between Lo and Hi)
2: Beep when it’s out of limit (>Hi value or <Lo value)
Press
[ON]
key to move the cursor and key
[FN]
to select the right number and then press
[ON]
to
confirm.
7.3
UF-3
Auto Switch Off
Press key
[ON]
to enter this menu and press
[ON]
again to move the cursor and press key
[FN]
to
set the right number and then press
[ON]
to confirm.
AoFF 00
=
Deactivate
AoFF 01
=
The time to power off, 01 = 1 minute, it will switch off after no
use for 1 minute, you can set it from 1 to 99 minutes.
7.4
UF-4
Standby Mode (LED version)