Fault

Reading does not return to 
zero between animals/Differ-
ence in readings at each end 
of the platform/Under 
reading(reading lighters than 
expected)

1.Ensure that the platform/crate 
is not touching objests that may 
alter the weights.
Typical causes are binding 
against fixed metalwork or built 
up of dirt.
2.Check that the load bar feet 
are sitting evenly on the  ground.
3.Check that bolt hole are not 
misaligned,as this may put a 
residual load on the load bars.
4.Recalibrate the load bars

1.Moisture in the load bar 
connector.
Remove moisture form the plugs 
and caps using methylated 
spirits.ethyl alcohol,or a suitable 
electriacl contact cleaner.
2.Damaged cable.
3.Moisture in the load cell.
4.Moisture in the junction box.

1.Damaged cable.
2.Damaged indicator.

Reading is unstable

Reading moves,display shows 
underload or overload.

4

Remedy

Section 5

Troubleshooting

Содержание HiRanchers ABH Series

Страница 1: ...ABH Load Bars A professional weighing products manufacturer and supplier An ISO9001 registered company Room 812 Building 3 Tiandu Tower No 211 Changjiang Road Suzhou City Jiangsu Province China www h...

Страница 2: ...INDEX Section 1 1 Unpacking the box Section 2 1 Weighing system Section 3 2 Getting around Section 4 3 Testing Section 5 4 Troubleshooting...

Страница 3: ...atform or crate and transmits the weight signal to the indicator The indicator will display and record the weight load bars platform indicator 1 Section 1 Unpacking the box For most applications you w...

Страница 4: ...d bar has two 13 mm diameter fixing holes and the foot plate has four 12 5 mm diameter fixing holes which can be installed under a platform or a crate Note Our company s AAC AAG can be matchedmatched...

Страница 5: ...the indicator Put the test weight at the other end of the platform crate and note the stable reading on the indicator Remove the test weight and note whether the reading returns to zero If the two rea...

Страница 6: ...feet are sitting evenly on the ground 3 Check that bolt hole are not misaligned as this may put a residual load on the load bars 4 Recalibrate the load bars 1 Moisture in the load bar connector Remov...

Страница 7: ...Do not leave the indicator load bars or plugs immersed in waters Cables shuold be placed so that they will not be damaged 5 Section 6 Further information...

Страница 8: ...An ISO9001 registered company Room 812 Building 3 Tiandu Tower No 211 Changjiang Road Suzhou City Jiangsu Province China www hiweigh com...