HT-100F Series
HITROL CO., LTD.
4
Specifications
Model
HT-100F
HT-100F(I)
Mounting
Top, Flange
Indicator
None
1-point dial
Ambient Temperature
−
20°C ~ +60°C
Process Temperature
Max. 80°C
Process Pressure
ATM
Range (m)
Max. 7.5m
Power Source
DC 24V
None (Std.) / DC 24V (Opt.)
Output
DC 4~20mA (2-wire)
Display (Std.) /
DC 4~20mA (2-wire) (Opt.)
Enclosure
Weather-proof (IP54)
Wetted Parts Material
316L SS
Process Connection
100A JIS 10K FF (Std.)
Cable Entry
PF 1/2"(F)
Accuracy
±
2% of F.S.
Specifications of the
R/I Converter
Item
Specification
Micom
16bit microprocessor
Supply Voltage
+17 ~ +40V at Typ. +24V
Operating Voltage
+3.3V
Current Consumption
2.5mA or less at sensor 1K
Ω
Status Indicator
Bi-color LED (green/red/orange)
Zero/Span Set
Tact switch
Wire Connection
One-touch connector
Ambient Temperature
−
20°C ~ +60°C
Dimension
80mm × 65mm × 20mm
Weight
54g
Current Loop Interface
2-wire loop current
Output Current Range (Accuracy)
4~20mA within
±
0.2%
Output Current Offset
±
0.2mA at 0.01mA / 20 steps
Measurement Sensor Range
30K
Ω
(15M) at sensor 10
Ω
Min.: 200
Ω
(100mm) / Max.: 50K
Ω
(25M) at sensor 20
Ω
Output Current Definite
TP