HM-90&95-Ex Series
HITROL CO., LTD.
4
Core
Enclosing tube
Socket
Cage
Pivot
RISING LEVEL
Switch Action
The core rises within the enclosing tube because of buoyancy when the level of measure object
rises and the displacer is submerged. The magnet which is connected with the switch responds to
trigger the switch when the core rises.
MAGNET
SNAP SWITCH
CORE
ENCLOSING TUBE
When the level of the object to be measured rises, the float also rises due to buoyancy
and, accordingly, the connected core also rises. When the core rises, a switch block
magnet responds to the core so as to trigger the switch.
Base
Cover
Float