HITROL HLT-1112 Скачать руководство пользователя страница 3

3

ALWAYS THE BEST SOLUTION

HITROL CO., LTD

HLT-1112 (HLT-1212)

 is a magnetic coupling type float level gauge which measures 

liquid level in a tank, by movement of a weight in a guide pipe according to a 
movement of a float, using a constant spring. Conventional level gauge is hard to be 
applied for corrosive and/or toxic liquids due to a corrosive vapor which is develped 
in a tank and comes up along a guide pipe to gauge head, can corrode inside 
components in a gauge head. On the other hand, magnetic coupling type float 
level gauge is a closed type and prevent an inflow of vapor into a guide pipe so it is 
suitable for corrosive and/or toxic liquids.

• Applicable to a tank which has a pressure (Max. 5kg/cm

2

). 

• Measurement in mm using spring balance
• Simplified design, high accuracy and durability 
• Operating checkup using a Drive Checker
• Easy installation and maintenance 
• Option for remote indication, control and switch for alarm 
• Large scale dial enables legible indication even at a distant location. 

The float in a tank floats on the surface of the liquid at the point which the float 
weight and buoyancy are in equilibrium, and the magnet in the float sticks to the 
magnetic in the weight which is installed in a guide pipe because the polarity of 
them is contrary. When the liquid level changes, weight moves according to the 
movement of the float and spring motor adjusts the measuring tape to maintain 
the float position on the surface of the liquid. The measuring tape has a series of 
holes set at regular intervals and as the tape rotates the sprocket, it in turn operates 
the display indicator. The position of the measuring tape holes on the sprocket 
compensates for the tape weight and prevents the tape from slipping.

 

She

av

e Elbow

Measuring 

T

ape

Gau

ge Head

Sprocket Wheel

Indica

tor

Gearing

Mechanism

T

ape Drum

Spring Mot

o

r

Spring Motor 

Drum

Magnet 

O

VERVIEW

FEATURES

OPERATING PRINCIPLE

Содержание HLT-1112

Страница 1: ...by HEAD OFFICE FACTORY R D INSTITUTE 141 Palhakgol Gil Jori Eup Paju Si Gyeonggi Do Korea Tel 82 31 950 9700 Fax 82 31 943 5600 Website www hitrol com INSTRUCTION MANUAL MAGNETIC COUPLING TYPE TANK L...

Страница 2: ...llation Process 1 Installation of Measuring Tape on Elbows 2 Installation of Measuring Tape and Spring Motor Inside the Tank 3 Installation of Measuring Tape Weight Side 4 Reference for the Bottom Anc...

Страница 3: ...tion and maintenance Option for remote indication control and switch for alarm Large scale dial enables legible indication even at a distant location The float in a tank floats on the surface of the l...

Страница 4: ...g Indicator 2 Points Dial Ambient Temperature 20o C 60o C Fluid Temperature Max 150o C Operating Pressure Up to 5kg cm2 Enclosure Weather Proof IP65 Application Liquid Measuring Range 2 5M 5M Specific...

Страница 5: ...ALWAYS THE BEST SOLUTION HITROL CO LTD SYSTEM COMPOSITION AND DETAILS OF PARTS HLT 1112 SCREW TYPE...

Страница 6: ...ALWAYS THE BEST SOLUTION HITROL CO LTD HLT 1212 FLANGE TYPE...

Страница 7: ...Std NPT 1 1 2 PF 1 1 2 and other Flange ANSI JIS and DIN Material 304SS 316LSS and other Connection Pipe User Scope Connection Socket Flange for Guide Pipe Nozzle Flange User Scope Guide Pipe Connect...

Страница 8: ...bottom anchor should be prepared by user 2 Installation of elbow and seal pipe in advance is fine However install the seal pipe on nozzle side to the elbow after installation of measuring tape and we...

Страница 9: ...unterclockwise to give a tension to the measuring tape The measuring tape without holes not perforated should not be positioned in the gauge head 2 INSTALLATION OF MEASURING TAPE AND SPRING MOTOR INSI...

Страница 10: ...omplete the installation of spring motor after fixing by upper locking ring Fix all spring loaded drum 1 and 2 PRECAUTION When the spring motor gets out of the spring loaded drum larger or excessive f...

Страница 11: ...ct the folded measuring tape to the weight as above The length of bolt should not be over 10mm because long bolt can cause a malfunction of the gauge 2 Put the weight connected with the measuring tape...

Страница 12: ...clockwise about 90o 1 4 turn the float is slightly lifted DIRECTION FOR THE INSTALLATION 1 Use the galvanized or stainless steel pipe for outside tank 2 Non linearity due to flexure of pipe must be li...