OPERATORS MANUAL

Process Monitor And Control Instrument                                              
PMAC 3000 

Содержание PMAC 3000

Страница 1: ...rsion 2 03 of the GUI software October 5 2017 HITEC Sensor Developments 1050 W Silver Bell Road Orion MI 48359 248 391 3000 Fax 248 391 0107 sales hitecsensors com www hitecsensors com HITEC Sensor De...

Страница 2: ...Record Display 9 Encoder optional 11 The Menu 12 External I O 15 Analog Output 16 Cycle On 17 Limit Outputs 17 Sensor Connection 20 Power Connection 20 Internal Batteries 20 Graphical User Interface...

Страница 3: ...number 1 248 391 3000 Features The PMAC 3000 features Six process monitoring functions including A continuous tracking function 3 peak logging functions 2 waveform recording functions with multiple re...

Страница 4: ...top of the PMAC 3000 The PMAC 3000 will power up Figure 1 PMAC 3000 Front Top and Rear View The first screen to appear describes the unit as a PMAC 3000 made by HITEC Sensor Developments The software...

Страница 5: ...ments autoID sensor the sensor information will reflect the autoID data If the sensor does not have the autoID feature installed the sensor information is that of the last sensor connected Figure 3 Se...

Страница 6: ...t hold the button a few seconds and release it Process Monitor Functions The PMAC 3000 provides six process monitoring functions Track Peak Peak Peak Auto Record Manual Record Track Track provides con...

Страница 7: ...ad is greater than the Sensor Target value The Sensor Target value is a programmable through the PMAC 3000 Menu See Menu section Peak Peak Peak The Peak functions sample the sensor at a rate of 10 000...

Страница 8: ...sitive or negative The user defined sensor Threshold and all limits are evaluated with respect to the absolute value of the reading so that the sign of the reading does not play a part in the evaluati...

Страница 9: ...See the Menu section Track Clicking Track will switch to the Track mode As stated earlier Track is the special case function that does not require a trip through the menu to activate Redo Peak Pressin...

Страница 10: ...r Threshold is evaluated with respect to the absolute value of the reading so that the sign of the reading does not play a part in the evaluation Note High Pass and Low limits are not evaluated in Rec...

Страница 11: ...Track mode for how to zero the sensor In addition the 1 represents the count of the last recorded plot In the case shown here the last recorded plot was the 1st plot in memory Battery Indicator A visu...

Страница 12: ...Screen Figure 11 shows the Recording Complete screen This is a more obvious visual indication that recording has ended Press Ok to return to the active recording screen Note that the Automatic Record...

Страница 13: ...it is evaluated in real time In the Track mode all limits are evaluated in real time In the Track mode Angle begins counting immediately and may be reset to zero by pressing the Tare button Note that...

Страница 14: ...tart of it As in Angle mode if the RPM value exceeds the encoder Target value the Target output will fire The Menu The PMAC 3000 provides an intuitive touch screen menu interface Press Menu from any o...

Страница 15: ...saves to memory Exit returns to System Settings Exit returns to Settings General Settings General Misc Settings Presets Select 1 5 Load loads selected presets as current settings Save saves current s...

Страница 16: ...try Screen E Target Limit Numeric Entry Screen E High Limit Numeric Entry Screen Exit returns to Settings Calibrate Sensor With autoID autoID Sensor Detected shows sensor info Exit returns to Settings...

Страница 17: ...Exit returns to Main Menu Re init PMAC 3000 pass code is 911 Re initialize will re initialize or format PMAC 3000 flash memory Exit returns to Main Menu Recorded Plots Erase One Plot Plot Selector Er...

Страница 18: ...l scale is accounted for This means that zero load on the sensor will produce 0V output for 10V and 5V ranges 5V for the 0 10V range and 2 5V for the 0 5V range The analog output uses the full 16 bits...

Страница 19: ...e Digital I O connector on the rear of the PMAC 3000 See Figure 1 The High Pass and Low limits reflect the status of their corresponding front panel indicators The Target output is a special case in t...

Страница 20: ...P M A C 3 0 0 0 Page 18 Figure 15 Limit Output Schematic Figure 16 Non Isolated TTL or CMOS Output...

Страница 21: ...P M A C 3 0 0 0 Page 19 Figure 17 Non Inductive Loads 1 5 amps Figure 18 Inductive Loads 1 5 amps Figure 19 High Voltage and or High Current Loads...

Страница 22: ...t to pin 5 Choose cable that keeps the sensor wires and encoder wires each grouped in their own shield The remaining pins are reserved for autoID Figure 20 Sensor Wiring Power Connection The PMAC 3000...

Страница 23: ...uired to read peaks and plots from the PMAC 3000 and store them to a file In addition it is also handy in that it makes easy work of modifying the PMAC 3000 settings To install the software and USB dr...

Страница 24: ...ngs screen See section on General Settings System Settings Brings up the System Settings screen See section on System Settings Peak Readings Brings up the Peak Readings screen See section on Peak Read...

Страница 25: ...t the user choose tab delimiting if the local numbering system uses commas instead of decimal points The user may also change the delimiter by pressing the F1 button from the GUI Main Screen General S...

Страница 26: ...t evaluated Target This value determines at which load the target output in the Digital I O becomes active High Limit This limit value draws a line between pass and fail on the upper side of the accep...

Страница 27: ...to the calibration of the attached sensor The user may read the calibration settings of the currently attached sensor by clicking Get sensor cal settings from sensor attached to PMAC 3000 If the senso...

Страница 28: ...elect the range of analog output voltage desired The analog output voltage is spread over the entire range of the sensor capacity from negative full scale to positive full scale This means that for ex...

Страница 29: ...s the user to upload view graph load and save peak readings See Figure 25 Figure 25 GUI Peak Readings Screen Get peak readings from PMAC 3000 Click to upload all peaks stored in memory Upload progress...

Страница 30: ...displayed at the bottom of the plot selector window Upload all plots from PMAC 3000 Uploads all plots from the PMAC 3000 to the PC Upload progress is displayed in Readings Buffer Info All plots are s...

Страница 31: ...process will begin The first thing to appear is the touch screen calibration Just follow the directions presented Use a non abrasive somewhat pointy object such as a bobby pin or toothpick to touch t...

Страница 32: ...put Type Quadrature TTL CMOS Power Supply 5VDC 100mA max Maximum Pulse Rate 200kHz Angle Sample Rate 10 000 samples second RPM Sample Rate 10 000 samples second difference calculated over last 05 seco...

Страница 33: ...packaging and any correspondence We will return the goods prepaid Products which have been exposed to hazardous materials will not be accepted unless they have been properly decontaminated HITEC Senso...