![HITEC Flash 7 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/hitec/flash-7/flash-7_user-manual_2139969007.webp)
status.
4.
Complete to save the Fail-safe position.
5.
Power off the Rx first then power off the Tx next.
6.
Enable the transmission system then turn off the transceiver.
7.
Check the servo move to the Fail-safe position.
-
Fail-safe Setting TEST
1.
The flight move to the any place that is not the Fail-safe setting.
2.
It is the normal Fail-safe setting if the servo moves to the Fail-safe position you set lastly after you turn off the Tx.
-
The way to re-enable the Hold mode in Fail-safe mode.
1.
Turn on Tx then check the transmission system works perfectly to the model.
2.
The red LED will turn off after press and hold Rx’s LINK button for 6 seconds then the red and green LED will flash in turn after release a
LINK button
3.
Press the LINK button one more time when the red and green LED flash in turn.
4.
The Fail-safe mode is disabled and The Hold mode is enabled.
5.
Power off the Rx first then power off the Tx next.
6.
You can use the transceiver in the Hold mode.
(Warning – The Fail-safe setting will delete you set lastly if the Fail-safe mode is disabled. Always check the Fail-safe mode work normally
before you turn on the engine or motor.)
Transmission Range Checks.
Always, It is very important to check the transceiver’s signal and range are normal or not before flight. Unlike FM/PPM and PCM, It is impossible to
verify the range of transmission to fold the antenna because the 2.4GHz antenna of Transceiver is short and fixed. Hitec 2.4GHz system can reduce the
signal strength of transmitter by force to use the Power-down mode. The Power-down mode reduces the range up to 30 meters. Please check the
minimum distance more than 30 meters between the Tx and Rx then make sure the Tx and Rx work normally in the Power-down time.