SAVE PROGRAM
SAVE...
[ BATT MEMORY 1 ]
LiPo
7.4V (2S)
Memory Set and Call Out
The charger can store up to 10 diff erent charge profi les for your convenience, and the stored profi les can
be recalled quickly without having to go through the setup process. To program, press START/ENTER to
make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER
once.
All following screens are taking 2S(7.4V) LiPo battery as the example.
Enter the battery memory program:
10 diff erent charge profi les can be stored.
Enter the battery memory program:
10 diff erent charge profi les can be stored.
Indicate the battery type and battery cell of the saved profi le.
Set the battery type:
(LiPo/LiHV/LiFe/LiIon/NiMH/NiCd/Pb).
Set the voltage and number of cells (2S-4S).
Set the charge current (0.1-5.0A).
Set the terminal voltage (4.18 -4.25V).
CHANGING THE TERMINAL VOLTAGE IS ONLY INTENDED
FOR EXPERT USERS, ANY CHANGES TO DEFAULT SETTINGS
ARE COMPLETELY AT YOUR OWN RISK.
Press ENTER to save program.
[BATT MEMORY 1]
ENTER SET ->
BATT TYPE
LiPo
BATT VOLTS
7.4V ( 2S )
CHARGE CURRENT
4.9A
TVC = YOUR RISK
4.20V
SAVE PROGRAM
ENTER
INC
►
INC
►
INC
►
INC
►
START
/
ENTER
B
UTTON
◄
DEC
◄
DEC
◄
DEC
◄
DEC
START
/
ENTER
B
UTTON
Warning
←
←
←
←
←
←
←
←
Note