![HITEC 44295 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/hitec/44295/44295_instruction-manual_2139862028.webp)
28
Nominal Voltage (V):
The nominal voltage of the battery pack can be determined as follows:
NiCd or NiMH:
Multiply the total number of cells in the pack by 1.2. An 8-cell pack will have a nominal voltage
of 9.6 volts (8 x 1.2).
LiPo:
Multiply the total number of cells in the pack by 3.7. A 3-cell LiPo wired in series will have a nominal
voltage of 11.1 volts (3 x 3.7). 4-cell LiHV wired in a series will have a nominal voltage of 14.8 volts. (4 x 3.7).
LiIon:
Multiply the total number of cells in the pack by 3.6. A 2-cell Lilon wired in a series will have a nominal
voltage of 7.2 volts (2 x 3.6).
LiFe:
Multiply the total number of cells in the pack by 3.3. A 4-cell LiFe wired in a series will have a nominal
voltage of 13.2 volts. (4 x3.3).
LiHV:
Multiply the total number of cells in the pack by 3.8. A 4-cell LiHV wired in a series will have a nominal
voltage of 15.2 volts. (4 x 3.7).
If the nominal voltage of the battery is not printed on the battery’s label, consult your
battery manufacturer or supplier. Do not attempt to guess the rated voltage of the
battery.
Hitec's RDX1 Mini satisfi es all relevant and mandatory CE directives and complies with FCC Part 15 Subpart B:
2010.
For EC directives:
The product has been tested to meet the following technical standards:
Commonly Used Terms Continued
Note