OFF /
(1 - 720 Min)
When starting a charge
process, the built-in safety
timer automatically runs at the
same time. This is programmed
to prevent the battery from
overcharging if it proves to be
faulty or if the termination circuit
cannot detect that the battery is
fully charged. The value for the
safety timer should be generous
enough to allow a full charge of
the battery. Default is 120 Min.
SYSTEM SETUP
DC Input:
Cut Caps: 5000mAh
Cut Time: 120 Min
Cut Temp: 50
0
C/122
0
F
11.0V
Celsius
Fahrenheit
1 - 60 Min
Display the temperature in
Celsius or Fahrenheit.
Rest Time allows the battery to
cool down between charging /
discharging cycles.
SYSTEM SETUP
SYSTEM SETUP
Unit:
Unit:
Resting: 10 Min
Resting: 10 Min
Delta Peak: 4mV
Delta Peak: 4mV
Bal. Connection: ON
Bal. Connection: ON
Celsius
Celsius
OFF /
(20
0
C / 68
0
F -
80
0
C / 176
0
F)
When charging or discharging
batteries, internal chemical
reactions will cause the
temperature of the battery to rise.
If the temperature limit is reached,
the process will be terminated
NOTE:
Requires the optional
temperature sensor Part #44159
SYSTEM SETUP
DC Input:
Cut Caps: 5000mAh
Cut Time: 120 Min
Cut Temp: 50
0
C/122
0
F
11.0V