--- 15 ---
10. REPAIR GUIDE
WARNING: Without fail, remove the Type EB 14B or EB 1430H Battery from the main body before starting
repair or maintenance work. Because the tool is cordless, if the battery is left in and the
switch is activated inadvertently, the motor will start rotating unexpectedly, which could
cause serious injury.
10-1. Precautions in Disassembly and Reassembly
The [Bold] numbers correspond to the item numbers in the Parts List and the exploded assembly diagram.
10-1-1. Disassembly
(1) Removal of Guide Sleeve [4]
Remove the Retaining Ring [1], Retainer [2], Guide Spring [3] and Guide Sleeve [4] in order by following the
procedure shown in Figs. 5-1 to 5-4. Be sure not to lose the two Steel Balls D3.97 [9] in Anvil (C) [10].
Hold the body and adjust the gap of the retaining
ring to the groove of anvil (C), then insert a small
flat-blade screwdriver into the groove at an angle.
Press down the retainer with the small flat-blade
screwdriver.
Fig. 5-2
Fig. 5-1
1
2
Small flat-blade screwdriver
Anvil (C) [10]
Retaining Ring [1]
Retainer [2]
Gap of retaining ring
Guide Sleeve [4]
Slide the small flat-blade screwdriver under one side
of the gap of the retaining ring.
Slowly raise the retaining ring using the end face of
guide sleeve as a fulcrum.
Fig. 5-4
Fig. 5-3
3
4
Then slowly raise the other side of the retainer ring with the small flat-blade screwdriver until it is free. Avoid
quickly raising the retainer ring or it may fly out forcefully.