Number
Item
Description
Blink red: Failure with the
power supply unit of the
controller.
Amber: LAN reset switch
was pressed.
9
LAN-RST switch
Use only when instructed by
customer support.
10
STATUS LED (for BKMF)
Green: Charging of the
battery in the backup module
is complete.
Red: Backup module can be
removed.
Blink red one time: Main
battery failure.
Blink red two times: Backup
battery failure.
Blink red three times: Both
batteries failed or preventive
maintenance replacement of
batteries can run.
Off: Battery is not mounted,
battery-mounting failure
occurred, or firmware is
being upgraded. Off is
normal status for
configurations without
batteries (for example,
BKMF-10 and BKMF-20).
CBLM rear panel
The following table describes the definitions of the CBLM controller rear panel LEDs.
CBLM rear panel
Chapter 2: Virtual Storage Platform N400, N600 controller
VSP N400, N600 Hardware Reference Guide
27