6 - 5
Adjustment > List of Adjustment Items
6-2 List of Adjustment Items
6-2-1 List of adjustments needed after replacing major
The following table shows the adjustment items, their purposes, and whether or not check is
required after replacing major components.
The components shown in the table below are the minimum to be checked after replacing major
components: If several components have been replaced - or depending on the cause of a defect more
components may need to be checked.
Table 6-2-1 List of adjustments needed after replacing major
: : : : : CHECK
*1: When replacing the PC circuit board or EEPROM, be sure to perform all adjustments only after "Data
Initialize".
*2: Since all adjustments must be performed any time "Data Initialize" is done, do not perform it
indiscriminately.
Electrical Parts
IC1001 IC1101 IC1201
IC1202
IC1250
(*1)
Other
Lens Block
Data Initialize
Data Initilize (*2)
Electric Volume
CDS Sampling Pulse
Camera Adjustment (Adjustment)
Initilizing EEPROM.
To suppress noise in the CCD sensor
output signal and maximize the signal
level.
IC1351
Items
Purpose Adjustment
Auto Iris
White Balance
Chroma Gain
To set the iris control data.
To input the automatic white balance
control data.
To set the color satuation under the
reference color temperrature.
Auto Focus
Spot Noise
Zoom/Focus Tracking
AF Noise Level
Check of Zoom/Focus
Trace
Spot Noise
To set the out-of -focus correction level
during zooming.
To set the noise level in the autofocus
circuit.
To check the autofocus adjustment.
To correct spot noise.
IR Control
IR Control
To set the IR filter control data.
Circuit
Board
PC