Item
Component
Specification
Transferred block size
512 bytes
Maximum number of hosts using a Fibre Channel switch
255
Maximum number of hosts using a network switch
255
RAID specifications
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides
data reliability enhanced by redundancy, there is a chance that user data could be lost
due to an unexpected host, storage system hardware, or software failure. Therefore,
users are requested to back up all data.
RAID Level
SAS, SAS 7.2k, flash drives mounted
RAID 1
2D+2D, 4D+4D
RAID 5
3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID 6
6D+2P, 12D+2P, 14D+2P
Item
Specification
Maximum number of RAID groups
480
Maximum volume size
3 TB (or 4 TB when using the LDEVs of
other storage systems)
Maximum volumes/host groups and iSCSI
targets
2048
Maximum volumes/parity groups
2048
Shared memory and data assurance
VSP G800 mechanical specifications
Appendix A: Mechanical specifications for VSP G800
Hitachi Virtual Storage Platform G800 Hardware Reference Guide