Item
Specification
Comments
Data digest
Supported
factors such as host
performance of host and
transaction pattern.
Maximum iSCSI
connections at one time
255 per iSCSI port
N/A
CHAP
Supported
Authentication: login
request is sent properly
from host to storage. CHAP
is not supported during
discovery session.
Mutual (2-way) CHAP
Supported (not available if
connected to Linux
software initiator)
Authentication: login
request is sent properly
from host to storage.
CHAP user registration
Max 512 users per iSCSI
port
N/A
iSNS
Supported
With iSNS (name service), a
host can discover a target
without knowing the
target's IP address.
Note:
1. JP1, HiCommand Dynamic Link Manager. Pass switching is achieved. Not
supported on Windows Vista and Windows 7 operating systems.
2. IP Security. Authentication and encryption of IP packets. The storage system does
not support IPsec.
3. iqn: iSCSI Qualified Name. The iqn consists of a type identifier, "iqn," a date of
domain acquisition, a domain name, and a character string given by the individual
who acquired the domain. Example:
iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar
4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui,"
and an ASCII-coded, hexadecimal, EUI-64 identifier. Example:
eui.0123456789abcdef
Managing cables
Organize cables to protect the integrity of your connections and allow proper airflow
around your storage system.
Managing cables
Appendix D: Data and power cables
Hitachi Virtual Storage Platform G700 Hardware Reference Guide
91