background image

7

VSP service processor server

The VSP Fx00 models include a separate, dedicated 1U service processor
(SVP) to host an element manager (Storage Navigator). The SVP (model
number 3919435.P) operates independently from the CPU of the storage
system and operating system, and provides out

of

band configuration and

management of the storage system. The SVP also monitors and collects
performance data for key components of the storage system to enable
diagnostic testing and analysis for customer support.

The SVP is available as:
• A physical 1U management server provided by Hitachi Data Systems that

runs Windows Embedded Standard 7.

• A software application that runs Windows 7 Professional x64 Service Pack

1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host,
or Linux KVM host.

• A software application that runs Microsoft Hyper-V Windows Server 2012

R2 on a customer-supplied server hardware running one of the following
64-bit operating systems:

Windows 10 Professional

Windows 10 Enterprise

Windows Server 2012

Windows Server 2012 R2

Service processor description

SVP front panel

SVP rear panel

Service processor hardware specifications

VSP service processor server

47

Hitachi Virtual Storage Platform F800 Hardware Reference Guide

Содержание Virtual Storage Platform F800

Страница 1: ...Hitachi Virtual Storage Platform F800 Hardware Reference Guide MK 94HM8046 07 July 2017 ...

Страница 2: ...uthorized employees and other individuals to access relevant data and 2 Verifying that data continues to be held retrieved deleted or otherwise processed in accordance with relevant laws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be...

Страница 3: ... VSP F800 model 15 Features 17 Scalability 17 Examples of supported VSP F800 configurations 17 Maximum number of mounted drive trays 17 2 Virtual Storage Platform F800 controller 19 CBLH controller 20 CBLH with front panel bezel 20 CBLH front panel without bezel 21 CBLH rear panel 22 CBLH power supply unit LEDs and connectors 24 3 Host Network and Drive Tray Ports and LEDs 25 Front end module desc...

Страница 4: ...t port expansion chassis power supply 43 6 NAS module 45 NAS Module Ports and LEDs 46 7 VSP service processor server 47 Service processor description 48 SVP front panel 48 SVP rear panel 49 Service processor hardware specifications 50 8 Maintaining the storage system 51 Storing the storage system 52 Powering off the storage system 52 A VSP F800 storage system components 53 Model lists 54 VSP F800 ...

Страница 5: ...al specifications for VSP F800 71 Environmental specifications 72 F iSCSI standards and specifications 75 iSCSI standards 76 iSCSI specifications 76 G Replacement parts 79 Battery unit 80 H Regulatory compliance 81 Index 83 5 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 6: ...6 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 7: ...800 all flash array Intended audience Safety and environmental notices Product version Release notes Changes in this revision Document conventions Conventions for storage capacity values Accessing product documentation Getting help Comments Preface 7 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 8: ...ore back up your data to minimize chances for data loss Data backup is also critical when hardware components are added or replaced because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems Disposal This symbol on the product or on its packaging means that your electrical and electronic equipment should be disposed at the end...

Страница 9: ... LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE FDA radiation regulation The array complies with FDA radiation pe...

Страница 10: ...s menus menu options buttons fields and labels Example Click OK Indicates emphasized words in list items Italic Indicates a document title or emphasized words in text Indicates a variable which is a placeholder for actual text provided by the user or for output by the system Example pairdisplay g group For exceptions to this convention for variables see the entry for angle brackets Monospace Indic...

Страница 11: ...ARNING Warns the user of a hazardous situation which if not avoided could result in death or serious injury Conventions for storage capacity values Physical storage capacity values for example disk drive capacity are calculated based on the following values Physical capacity unit Value 1 kilobyte KB 1 000 10 3 bytes 1 megabyte MB 1 000 KB or 1 0002 bytes 1 gigabyte GB 1 000 MB or 1 0003 bytes 1 te...

Страница 12: ...hi Data Systems To contact technical support log on to Hitachi Data Systems Support Connect for contact information https support hds com en_us contact us html Hitachi Data Systems Community is a global online community for HDS customers partners independent software vendors employees and prospects It is the destination to get answers discover insights and make connections Join the conversation to...

Страница 13: ...ler The storage system can be equipped with embedded network attached storage NAS modules The NAS modules provide file access through CIFS and NFS protocols and block access by using iSCSI protocols All storage system models allow defective drives to be replaced without the interruption of data availability to hosts A hot spare drive can be configured to replace a failed drive automatically securi...

Страница 14: ... Features Scalability 14 Hitachi Virtual Storage Platform F800 hardware overview Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 15: ... 1U block service processor server SVP VSP F800 model The VSP F800 is a highly reliable all flash system that offers high storage capacity with full redundancy to better protect data and manage storage operations The storage system consists of a 4U enclosure that includes two controllers Drives are supported using drive trays connected to the controllers Controller Controller chassis Controller mo...

Страница 16: ...acity is 4 355 TB Model number Drive type Drive capacity DKC F810I 1R9MGM SSD 1 9 TB DKC F810I 3R8MGM SSD 3 8 TB Interface ports Interface ports for attachment to hosts are provided on the front end modules The system supports 24 front end modules Model number Description Maximum number of ports supported DW F800 2HS10S 10 Gbps iSCSI optical front end module 24 DW F800 2HS10B 10 Gbps iSCSI copper ...

Страница 17: ...ity All storage systems offer pay as you grow scalability by allowing you to hot add drives as you need them Examples of supported VSP F800 configurations The following table lists the maximum number of drive trays and drives supported in a system configuration A diskless configuration does not include any drive trays Drive tray Maximum number of drive trays supported Maximum number of drives supp...

Страница 18: ...0 slots per path the drive is blocked VSP F800 controller Drive trays Maximum number of trays Maximum number of drives CBLH FMD 48 576 FMDs HAF FMD 4 40 FMDs 2 spares DC2 48 FMDs SFF 48 1 152 SSDs 18 Hitachi Virtual Storage Platform F800 hardware overview Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 19: ... Ethernet connection for out of band management using Hitachi Device Manager Storage Navigator If the data path through one controller fails all drives remain available to data hosts using a redundant data path through the other controller The controller is equipped with LED indicators for monitoring its operating conditions and notifying possible component replacement CBLH controller Virtual Stor...

Страница 20: ... Amber Storage system is receiving power 2 READY LED Green Normal operation 3 WARNING LED Off Normal operation Amber Component requires maintenance Blink Failure requires maintenance Note When System Option Mode 1097 is set to ON the WARNING LED does not blink even if the following failure service information messages SIM are issued 452xxx 462xxx 3077xx 4100xx and 410100 LED might turn off during ...

Страница 21: ...ge system recovers from the controller replacement CBLH front panel without bezel The following table describes the definitions of the CBLH controller front panel LEDs Number Item Description 1 POWER ON OFF main switch Powers the storage system 2 POWER READY WARNING and ALARM LEDs Note When System Option Mode 1097 is set to ON the WARNING LED does not blink even if the following failure service in...

Страница 22: ...upport 10 STATUS LED for BKMF Green Charging of the battery in the backup module is complete Red Backup module can be removed Blink red one time Main battery failure Blink red two times Backup battery failure Blink red three times Both batteries failed or preventive maintenance replacement of batteries can run Off Battery is not mounted battery mounting failure occurred or firmware is being upgrad...

Страница 23: ...tem 1 Power supply unit 2 Front end module 3 Back end module 4 LAN blade Rear view includes NAS modules Virtual Storage Platform F800 controller 23 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 24: ...ists the definitions of the CBLH power supply unit LEDs and connectors Number Item Description 1 ALM RDY LED Red Power supply unit can be replaced 2 Receptacle Connects to the power cable provided with the storage system 3 RDY LED Green Normal operation 24 Virtual Storage Platform F800 controller Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 25: ...ng configuring and managing the storage system The component LEDs display the operating status of the storage system Front end module descriptions LAN blade LEDs and connectors Back end module LEDs and connectors Host Network and Drive Tray Ports and LEDs 25 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 26: ...s in the power on state Red Front end module can be removed safely 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status Blink blue Front end module is in communication status 3 iSCSI connectors Connect to Ethernet LAN cables 10 Gbps iSCSI board LEDs and connectors copper 26 Host Network and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform F800 Hardware Refere...

Страница 27: ...ff No link connection 3 PORT LED Green Link connection is established Blinking Communication is in progress Off No link connection or not ready to communicate 4 iSCSI connectors Connect to Ethernet LAN cables 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LEDs and connectors Host Network and Drive Tray Ports and LEDs 27 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 28: ...Normal link status at 2 Gbps or 4 Gbps Table 2 32 Gbps 16 Gbps Fibre Channel Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables 2 STATUS LED Green Front end module is in power on state Red Front end module can be removed safely 3 PORT LED Red Small form factor pluggable can be removed Blue Normal link status at 16 Gbps 16 Gbps Blue Normal link status at 32 Gbps 32 G...

Страница 29: ... 3A 5A 7A CHB 1B 1B 3B 5B 7B CHB 1C 1C 3C 5C 7C CHB 1D 1D 3D 5D 7D CHB 1E 1E 3E 5E 7E CHB 1F 1F 3F 5F 7F CHB 1G 1G 3G 5G 7G CHB 1H 1H 3H 5H 7H CHB 2A 2A 4A 6A 8A CHB 2B 2B 4B 6B 8B CHB 2C 2C 4C 6C 8C CHB 2D 2D 4D 6D 8D CHB 2E 2E 4E 6E 8E CHB 2F 2F 4F 6F 8F CHB 2G 2G 4G 6G 8G CHB 2H 2H 4H 6H 8H 16 Gbps Fibre Channel 2 port board LEDs and connectors Host Network and Drive Tray Ports and LEDs 29 Hita...

Страница 30: ...nnel connectors Connect to Fibre Channel cables Port assignments CHB number 16 Gbps Fibre Channel Ports left to right Port 1 Port 2 CHB 1A 1A 3A CHB 1B 1B 3B CHB 1C 1C 3C CHB 1D 1D 3D CHB 1E 1E 3E CHB 1F 1F 3F CHB 1G 1G 3G CHB 1H 1H 3H CHB 2A 2A 4A CHB 2B 2B 4B CHB 2C 2C 4C CHB 2D 2D 4D CHB 2E 2E 4E CHB 2F 2F 4F CHB 2G 2G 4G CHB 2H 2H 4H LAN blade LEDs and connectors 30 Host Network and Drive Tray...

Страница 31: ...Maintenance LAN port used by service personnel 5 LAN ALARM LED Red LAN blade can be removed 6 Uninterruptible power supply UPS port N A Back end module LEDs and connectors The back end module LEDs display the operating status of the module Host Network and Drive Tray Ports and LEDs 31 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 32: ...tate Red Back end module can be removed safely 2 Port LED Blue Link status is normal 3 PATH 0 connector Connect to a drive tray 4 PATH 1 connector Connects to a drive tray 32 Host Network and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 33: ...ge arrays have various fixed storage capacity configurations with FMD DC2 flash storage devices To deliver consistent low latency host response times and highest IOP performance across all host connection ports conventional HDDs are not included or configurable with all flash arrays Flash module drive FMD tray Storage system drive trays 33 Hitachi Virtual Storage Platform F800 Hardware Reference G...

Страница 34: ...en Drive tray is operational 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key FMD front panel without bezel 34 Storage system drive trays Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 35: ... is finished charging approximately two minutes Note ACT indicator is only printed on some types of FMDs ALM LED Red Drive stopped due to a failure and can be replaced Note ACT indicator is only printed on some types of FMDs 3 POWER READY and LOCATE LEDs Green Drive tray is powered on Green Drive tray is operational Amber Indicates the location of the chassis Storage system drive trays 35 Hitachi ...

Страница 36: ...A 2 POWER LED Green ENC is in the power on state 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 ALARM LED Red ENC can be replaced 5 PATH IN LED Blue IN side port is linked up 6 PATH IN connector Connects to a controller or drive tray 7 PATH OUT LED Blue OUT side port is linked up 36 Storage system drive trays Hitachi Virtual Sto...

Страница 37: ...e power cable provided with the storage system 11 Three LEDS top to bottom RDY LED AC IN LED ALM REPLACE LED Green Power supply unit is operating normally Green Power supply unit is operating normally Red Power supply unit can be replaced Storage system drive trays 37 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 38: ...38 Storage system drive trays Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 39: ...The interconnect adapters include PCIe boards iSCSI and FC cards For more information contact customer support Host port expansion chassis front panel bezel LEDs PCIe switchboard Host port expansion chassis fan PCIe cable connector Host port expansion chassis power supply Host port expansion chassis 39 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 40: ...tion 1 POWER LED Green Host port expansion is turned on Amber PCIe module is turned on Off PCIe module is turned off 2 Safety lock Lock or unlock the front bezel PCIe switchboard 40 Host port expansion chassis Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 41: ...ard can be replaced safely Off PCIe switchboard is powered off Host port expansion chassis fan Number Item Description 1 ALM LED Red Fan failure has occurred Off Normal operation PCIe cable connector Host port expansion chassis 41 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 42: ...ed up PCIe cable might not be connected If a cable is connected it can be removed safely 3 InAct Basic LED Amber Basic PCIe status changed from link up to link down and cables Cables can be removed safely Off Basic PCIe is normal or not set 4 Link Option LED Green Option PCIe Gen 3 0 8 Gbps is linked up normally Off Option PCIe is not linked up PCIe cable might not be 42 Host port expansion chassi...

Страница 43: ...les Cables can be removed safely Off Option PCIe is normal or not set Host port expansion chassis power supply Number Item Description 1 ALM RDY LED Red Host port expansion chassis power supply can be replaced safely Green Normal operation 2 AC IN LED Blue AC input is normal Host port expansion chassis 43 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 44: ...44 Host port expansion chassis Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 45: ...e NAS module provides communication ports to support file system protocols in a block or file system configuration NAS Module Ports and LEDs NAS module 45 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 46: ...2 3 Target group 3 4 Target group 4 5 Target group 5 6 Target group 6 2 Cluster port Reserved for future use 3 Status LED Green NAS modules are functioning normally Red NAS modules can be removed 4 Link LED Blue Displays link status 5 Fail LED Red A failure has occured 46 NAS module Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 47: ...s A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7 A software application that runs Windows 7 Professional x64 Service Pack 1 64 bit on a customer supplied server hardware a VMware ESXi host or Linux KVM host A software application that runs Microsoft Hyper V Windows Server 2012 R2 on a customer supplied server hardware running one of the follo...

Страница 48: ...ult SVP IP address dev storage model number system serial number emergency do For example Storage system model number Storage system serial number URL 8320004 456789 http 192 168 0 15 dev storage 8320004456789 emergency do 8340004 456789 http 192 168 0 15 dev storage 8340004456789 emergency do 8360004 456789 http 192 168 0 15 dev storage 8360004456789 emergency do Users are responsible for adoptin...

Страница 49: ...r removes power from the SVP SVP rear panel The only ports used on the rear panel of the physical SVP are the power socket and the four LAN ports Number Description 1 Power socket Attach the power cable supplied with the SVP 2 Four LAN ports arranged as follows LAN3 LAN4 LAN1 LAN2 VSP service processor server 49 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 50: ...y Hitachi Data Systems Caution The SVP is not supported in high temperature environments Do not operate it in locations with temperatures of 40 C or higher Item Specification Dimensions Height 1 7 inches 43 mm Width 17 2 inches 437 mm Depth 14 5 inches 369 mm Weight 14 lbs 6 4 kg Processor Celeron G1820 2 7 GHz 2M 2C 2T Cores 2 Instruction set 64 bit SmartCache 2 MB Maximum memory size 32 GB Memor...

Страница 51: ...ity of the storage system and its constant availability to all hosts connected to it For more complex maintenance activities contact customer support Storing the storage system Powering off the storage system Maintaining the storage system 51 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 52: ...front of the storage system changes from green to amber Wait 25 minutes to 4 hours for the POWER LED to turn amber depending on the system configuration check after 33 minutes 3 To stop the power supply remove the power cables from the power supply units on the controller chassis and drive box If the storage system is connected to a PDU you can stop the power supply by turning off the PDU breaker ...

Страница 53: ...ocks such as controllers drive trays and other optional front and back end components Model lists Drive tray model lists Cable model list Battery specifications RAID specifications VSP F800 storage system components 53 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 54: ...d 2 DKC F810I CM8G Cache memory 8 GB 8 16 DKC F810I CM16G Cache memory 16 GB 8 16 DKC F810I CM32G Cache memory 32 GB 8 16 DW F800 BM30 Cache flash memory 2 4 DW F800 2HS10S Front end module 10 Gbps SFP iSCSI optical 2 16 DW F800 2HS10B Front end module 10 Gbps SFP iSCSI copper 2 16 DW F800 4HF8 Front end module 8 Gbps 4 port FC 2 16 DW F800 2HF16 Front end module 16 Gbps 2 port FC 2 16 DW F800 4HF...

Страница 55: ... F800 BAT Battery 0 14 N A SAS cable label 2 CHBB front end module components Model number Part name Quantity DW F800 CHBB PCP 2 IOEXBX 1 Power supply unit 2 PCIe switch board fan 5 2 PCIe module 2 PCIe cable 1 5 m 2 Front bezel 1 Accessories kit 1 Drive tray model lists SFF drive tray components AC power Model number Part name Quantity DW F800 DBS and DW F800 DBSC 2U chassis 1 ENC 2 AC power supp...

Страница 56: ... 5 m 2 Front bezel 2U 1 FMD tray optional components Model number Part name Quantity DKC F810I 1R6FN1 1 75 TB Flash Module Drive 0 12 DKC F810I 3R2FN1 3 5 TB Flash Module Drive 0 12 DKC F810I 6R4FN1 7 TB Flash Module Drive 0 12 DKC F810I 7R0FP1 7 TB MLC 12 Gbps Flash Module Drive 0 12 DKC F810I 14RFP1 14 TB MLC 12 Gbps Flash Module Drive 0 12 1 The drive capacity values are calculated as 1 G byte ...

Страница 57: ...SCQ5 5 m SAS cable including omega clips 2 DW F800 SCQ10A 10 m SAS optical cable DW F800 SCQ30A 30 m SAS optical cable DW F800 SCQ1HA 100 m SAS optical cable Optical cables Model number Specification A 6515 GM5L 5 m LC LC optical cable for optical A 6515 GM10L 10 m LC LC optical cable for optical A 6515 GM20L 20 m LC LC optical cable for optical A 6515 GM30L 30 m LC LC optical cable for optical A ...

Страница 58: ... m LC LC optical cable for optical A 6515 JM30L 30 m LC LC optical cable for optical A 6515 JM50L 50 m LC LC optical cable for optical A 6515 JM100L 100 m LC LC optical cable for optical A 6515 JM200L 200 m LC LC optical cable for optical A 6515 JM300L 300 m LC LC optical cable for optical Battery specifications The following table shows the lifetime expectancy of the batteries installed in the st...

Страница 59: ...D 4D 4D RAID 5 3D 1P 7D 1P RAID 6 6D 2P 14D 2P Note Although certain RAID configurations support redundancy in the event of a drive failure best practices dictate that you back up data on a regular basis VSP F800 storage system components 59 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 60: ...60 VSP F800 storage system components Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 61: ...er of spare drives 1 64 Maximum number of LDEVs 16 384 Maximum storage system capacity physical capacity 8 106TB using 14TB FMD 4 356 TB using 3 8 TB SSD Maximum external configuration 64 PB Maximum number of DBs 48 Memory Cache memory capacity 64GB to 512GB Cache memory capacity with NAS module is installed 256 GB 512 GB Cache flash memory BM30 Storage I F DKC to drive interface SAS Dual Port Dat...

Страница 62: ...intenance Control PCB Supported Cache memory Supported Cache flash memory Supported Power supply fan Supported Microcode Supported Flash Drive Flash Module Drive Supported Notes 1 Available as spare or data drives 2 The port can be changed to long wavelength by replacing the SFP transceiver of the fibre port on the CHB to the DKC F810I 1PL8 1PL16 3 Measurement Condition The point 1m away from the ...

Страница 63: ... specifications The storage system mechanical specifications are described for VSP F800 VSP F800 mechanical specifications VSP F800 storage system mechanical specifications 63 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 64: ...nsists of an ENC and AC DC power supplies equipped with built in cooling fans NAS module Component Description NAS module Optional component for block and file storage configuration Drive size Component Specification Flash Module Drive flash module drive tray 5 74 x 14 44 x 0 78 inches 146 x 366 8 x 19 8 mm Data capacity GB Component Specification Flash Module Drive flash module drive tray 1759 21...

Страница 65: ...ransfer speed maximum speed for transfer to host Fibre Channel optical 800 Mbps Fibre Channel 1600 Mbps Fibre Channel 3200 Mbps Fibre Channel iSCSI optical 10 Gbps iSCSI optical iSCSI Copper 10 Gbps iSCSI copper NAS module Fibre Channel 1000 Mbs VSP G800 maximum number of ports 8 Gbps Fibre Channel optical 64 16 Gbps Fibre Channel optical 2 port 32 16 Gbps Fibre Channel optical 4 port 64 32 Gbps F...

Страница 66: ...AS module installed 8 Gbps Fibre Channel optical 32 16 Gbps Fibre Channel Optical 2 port 16 16 Gbps Fibre Channel Optical 4 port 32 32 Gbps Fibre Channel Optical 4 port 32 10 Gbps iSCSI optical 16 10 Gbps iSCSI copper 16 10 Gbps Fibre Channel optical 12 Transferred block size 512 bytes Maximum number of hosts using a Fibre Channel switch 255 Maximum number of hosts using a network switch 255 RAID ...

Страница 67: ...2 M bytes L3 Cache memory 4 M bytes SDRAM 1 G bytes Data bus Parity Cache memory ECC 1 bit for correction 2 bits for detection Drive Data assurance code Start up time Item Standard 5 to 10 minutes The start up time may be longer in proportion to the number of drive trays connected With a maximum configuration 1 controller tray and 19 drive trays start up time is approximately 10 minutes Chassis si...

Страница 68: ...ity is not sufficient the storage system will continue operating with the Write Cache function disabled When the battery is charged the warning indication disappears and the storage system continues the operation in the Write Cache function The warning indication disappears within six hours Even when the warning is shown normal operation is assured in Write Through Read and write performance is lo...

Страница 69: ...fications for VSP F800 The electrical specifications are described for the storage system Electrical specifications Electrical specifications for VSP F800 69 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 70: ...780 or less FMD drive tray 440 420 or less Notes 1 The power current of Nx2 described in this table is required for a single power unit 2 If one power unit fails another power unit requires electric current for the two power units Therefore plan the power supply facility so that the current carrying capacity for one power unit can provide the total capacity for two power units 3 This table shows t...

Страница 71: ...ations for VSP F800 The environmental specifications are described for the storage system Environmental specifications Environmental specifications for VSP F800 71 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 72: ... to 104 F 10 C to 40 C Non operating 14 F to 122 F 10 C to 50 C 14 F to 95 F 10 C to 35 C Transport storage 22 F to 140 F 30 C to 60 C 22 F to 122 F 30 C to 50 C Temperature change rate C h 10 or less Humidity State Percentage Operating 8 to 80 Non operating 8 to 90 Transport storage 5 to 95 Maximum wet bulb temperature C 29 non condensing Vibration State m s2 Operating 2 5 or less Within 5 second...

Страница 73: ... State Controller FMD Operati ng 60 dB Environmental temperature 32 C or less 1 60 dB Environmental temperature 32 C or less 1 2 3 Non operati ng 55 dB Environmental temperature 32 C or less 1 2 3 4 55 dB Notes 1 The system s internal temperature controls the rotating speed of the fan module Therefore this standard value might be exceeded if the maximum load continues under high temperature enviro...

Страница 74: ...by the ISO 7779 standard is 7 2 B This value changes from 7 2 B to 8 1 B according to the ambient temperature drive configuration and operating status 74 Environmental specifications for VSP F800 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 75: ...he following tables describe the standards and specifications for using iSCSI in a hosting environment iSCSI standards iSCSI specifications iSCSI standards and specifications 75 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 76: ... Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueCopy only iSCSI ports 2 per interface board VSP Fx00 models Maximum 24 per iSCSI system Connection methods Direct and switch connections Host connections 255 maximum per iSCSI port With Linux software initiator the maximum number decreases Path failover HDLM1 Supports Microsoft MPIO Multi Path I O ...

Страница 77: ...n IPv6 router If the IPv6 router does not exist in the network the address cannot be determined As a result an iSCSI connection might be delayed When an iSCSI Port IPv6 is set to Enabled verify the IPv6 router is connected to the same network and then set IPv6 global address automatically Subnet mask Supported N A Gateway address Supported N A DHCP N A N A DNS N A N A Ping ICMP ECHO Transmit Recei...

Страница 78: ... discovery session Mutual 2 way CHAP Supported not available if connected to Linux software initiator Authentication login request is sent properly from host to storage CHAP user registration Max 512 users per iSCSI port N A iSNS Supported With iSNS name service a host can discover a target without knowing the target s IP address Note 1 JP1 HiCommand Dynamic Link Manager Pass switching is achieved...

Страница 79: ...t is essential for maintaining the high performance of the system Replacing system components is covered by the maintenance service contract Battery unit Replacement parts 79 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 80: ... in keeping with the terms of the contract Note The battery protects the data in the cache memory in an emergency such as a sudden power failure In these cases follow the normal power down procedure If not the battery might reach its lifespan earlier than expected and become unusable within three years When replacing the battery follow the given procedure for disposing a used battery 80 Replacemen...

Страница 81: ...09 A1 RCM Australia and New Zealand TP TC 020 2011 EAC Russia Belarus and Kazakhstan CNS 13438 BSMI Taiwan KN22 KC Korea KN24 KC Korea Electronic emission certifications EN5522 2010 CE EU EN5524 2010 CE EU EN61000 3 2 2006 A1 A2 CE EU EN61000 3 3 2008 CE EU Safety certifications UL and CSA 60950 1 2007 cTUVus USA and Canada EN60950 1 2006 A1 TUV Germany IEC60950 1 2005 A1 N A All CB countries IEC6...

Страница 82: ...on Product marking or logo Country regulation EN60950 1 2006 A1 CE EU Radio interference voluntary control VCCI V 3 2013 04 VCCI Japan 82 Regulatory compliance Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 83: ...mber 17 E electrical 69 electrical specifications 70 environmental 71 environmental specifications 72 F fan host port expansion chassis 41 features 17 flash module drive tray 34 rear panel 36 with front panel bezel 34 without front panel bezel 34 front end modules 10 Gbps iSCSI board copper 26 10 Gbps iSCSI board optical 26 16 Gbps Fibre Channel board 27 29 32 Gbps Fibre Channel board 27 8 Gbps Fi...

Страница 84: ... rear panel of physical SVP 49 rear panels CBLH controller 22 CBLM controller 22 flash module drive tray 36 regulatory compliance 81 replacement parts 79 battery unit 80 S scalability 17 service processor 47 48 specifications 63 69 71 75 battery 58 electrical 70 environmental 72 hardware 50 iSCSI 76 mechanical 64 RAID 58 storage system 53 standards 75 standards for iSCSI 76 storage 63 storage syst...

Страница 85: ...Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...

Страница 86: ...rnia 95050 2639 U S A www hds com Regional Contact Information Americas 1 408 970 1000 info hds com Europe Middle East and Africa 44 0 1753 618000 info emea hds com Asia Pacific 852 3189 7900 hds marketing apac hds com Contact Us www hds com en us contact html MK 94HM8046 07 July 2017 ...

Отзывы: