--- 18 ---
(3) Trouble mode (C)
NO
NO
YES
YES
YES
YES
NO
Is ambient temperature
within designated range (between
0˚C and 40˚C) ?
Is the
battery very
hot ?
Are the connection
terminals of the charger
or the battery dirty or
deformed ?
S, G, B, M and
H-type batteries: Is the
resistance between
(S) and (---) terminals 2 K
Ω
to 100 K
Ω
?
EB 7, EB 9 and EB 12 batteries:
Is there continuity between (T)
and (---) terminals?
Faulty internal circuits
Replace case (B) (PCB).
Pilot lamp remains green (red fails to light) after
battery has been connected.
Allow battery to cool prior to
charging
NO
Conduct charging within
designated temperature range.
0˚C
---
40˚C
Clean, or repair deformed
terminals.
For the S, G, B and M-types batteries, charging cannot
be accomplished if battery temperature is above 60˚C.
For H-type battery, charging cannot be accomplished if
battery temperature is above 45˚C.
For the EB 7, EB 9 and EB 12 batteries, charging cannot
be accomplished if battery temperature is above 40˚C.
Replace battery.
Содержание UC 24YC
Страница 23: ... 21 Assembly Diagram for UC 24YC ...