![Hitachi UC 14YFA Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/hitachi/uc-14yfa/uc-14yfa_technical-data-and-service-manual_140007018.webp)
16
(3) Trouble mode (C)
NO
NO
YES
YES
YES
YES
NO
Is ambient temperature
within designated range (between
0 ˚C and 40 ˚C) ?
Is the
battery very
hot ?
Are the connection
terminals of the charger
or the battery dirty or
deformed ?
Is the resistance
between (S) and (---) terminals
2 K
Ω
to 100 K
Ω
?
Faulty internal circuits
Replace PCB.
Pilot lamp remains green (red fails to light) after
battery has been connected.
Allow battery to cool prior to
charging
NO
Conduct charging within
designated temperature range.
0 ˚C to 40 ˚C
Clean, or repair deformed
terminals.
For the Ni-Cd batteries, charging cannot be accomplished
if battery temperature is above 55 ˚C.
For the H-type batteries, charging cannot be accomplished if
battery temperature is above 45 ˚C.
Replace battery.
Содержание UC 14YFA