4-1. Selling Point Descriptions

4-1-1. Rotary hooked handle

The Model UB 12DL has a rotary hooked handle.  It can be locked in eight positions in increments of 45˚ (0˚, 45˚,

90˚, 135˚, 180˚, 225˚, 270˚ and 315˚).  The hooked handle can be hung on a pipe up to 50 mm (2 inches) in

diameter.

* Note  When hanging the Model UB 12DL on a pipe 30 mm (1-3/16 inches) or more in diameter, turn the handle

  to any position other than the 0˚ position and then hang it on the pipe.  It is impossible to hang the Model

  UB 12DL on a pipe 30 mm (1-3/16 inches) or more in diameter when the handle is in the 0˚ position

  because the lamp cover contacts such a pipe in the 0˚ position.

4-1-2. Stand

The stand ensures stable operation even if an unstable conventional vertical battery is used.

4-1-3. Holes for attaching a strap

There are two holes for attaching a user's strap at both sides of the upper portion of the handle.

4-1-4. LED small light

The Model UB 12DL has a white LED that can be operated for about 150 hours when using a fully charged 3-Ah

battery.  The LED can be lit for a long time because it consumes low power while it has high directivity.  The Model

UB 12DL is convenient as an all-night light if so bright light is not required.

* The LED will be dim if the battery is nearly discharged.  When using a Ni-MH battery, it may adversely affect the

   battery such as decrease in the charging capacity and the service life because the Ni-MH battery may be over-

   discharged.  It is recommended to turn off the switch immediately and charge the Ni-MH battery.

4-1-5. Automatic LED switching function

The Model UB 12DL automatically switches lighting from fluorescent lamp to LED when the battery voltage is

decreased to about 8.5 V to prevent from being extinguished suddenly.

Содержание UB 12DL

Страница 1: ...TECHNICAL DATA AND SERVICE MANUAL CORDLESS LANTERN UB 12DL SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT LIST No G813 Jul 2004 U MODEL UB 12DL Hitachi Power Tools ...

Страница 2: ...AND SERVICE MANUAL a symbol s is are used in the place of company name s and model name s of our competitor s The symbol s utilized here is are as follows Symbol Utilized Competitor Company Name Model Name MAKITA ML122 C Panasonic EZ3791 P ...

Страница 3: ...fication Comparisons with Similar Products 3 5 2 Specification Descriptions 3 6 PRECAUTIONS IN SALES PROMOTION SAFETY INSTRUCTIONS 5 7 REPLACEMENT OF LAMP LAMP CAP AND LAMP COVER 6 7 1 Replacement of Lamp 6 7 2 Replacement of Lamp Cover 6 7 3 Replacement of Lamp Cap 6 8 SPARE PARTS 6 9 STANDARD REPAIR TIME UNIT SCHEDULES 7 Assembly Diagram for UB 12DL ...

Страница 4: ...e up to 50 mm 2 inches in diameter and locked in eight positions in increments of 45 It is also possible to lock the lantern upside down LED small light Usable for 150 hours as an all night light when using a 3 Ah battery Holes for attaching a strap The handle has holes to attach a user s strap Automatic LED switching function It automatically switches lighting from fluorescent lamp to LED when th...

Страница 5: ...hing a strap There are two holes for attaching a user s strap at both sides of the upper portion of the handle 4 1 4 LED small light The Model UB 12DL has a white LED that can be operated for about 150 hours when using a fully charged 3 Ah battery The LED can be lit for a long time because it consumes low power while it has high directivity The Model UB 12DL is convenient as an all night light if ...

Страница 6: ...epends on the ambient temperature The light may be dim if the ambient temperature is extremely low 5 2 2 Continuous operating time Continuous operating time means the continuous lighting time when using a fully charged battery It varies in accordance with the frequency of use battery capacity and other factors Accordingly the continuous operating time values in the above table are intended for ref...

Страница 7: ...shes suddenly if the battery voltage becomes low To prevent this the Model UB 12DL automatically switches lighting from fluorescent lamp to LED when the battery voltage is decreased to about 8 5 V The LED will be dim if the battery voltage becomes lower When using a Ni MH battery it may adversely affect the battery such as decrease in the charging capacity and the service life because the Ni MH ba...

Страница 8: ... the switch off before replacing the fluorescent lamp or when not in use Otherwise the service life of the fluorescent lamp may be shortened and short circuit may be caused If the Model UB 12DL is left for a long time with the switch turned on and the battery installed the service life of the battery may also be shortened due to over discharge 4 Do not use the Model UB 12DL in the rain The Model U...

Страница 9: ...breakage of the lamp in case of accidental drop of the Model UB 12DL Be sure to reinstall the Lamp Cap 2 to the new Lamp 3 7 2 Replacement of Lamp Cover 1 1 Remove the Lamp Cover 1 by tuning it counterclockwise in C direction Fig 3 2 Install the new Lamp Cover 1 by turning it clockwise in D direction without twisting the Lamp Cap 2 7 3 Replacement of Lamp Cap 2 1 Remove the Lamp Cover 1 by tuning ...

Страница 10: ... 7 9 STANDARD REPAIR TIME UNIT SCHEDULES MODEL 10 20 30 40 Fixed Variable UB 12DL Work Flow Main Body Lamp Lamp Cover Lamp Cap 60 min 50 General Assembly ...

Страница 11: ...ELECTRIC TOOL PARTS LIST LIST NO G813 CORDLESS LANTERN Model UB 12DL 2004 7 10 E1 Hitachi Power Tools 1 2 3 4 ...

Страница 12: ... ALTERNATIVE PARTS 2 ITEM NO CODE NO DESCRIPTION REMARKS NO USED PARTS 7 04 UB 12DL Printed in Japan 040710N 1 323 340 LAMP COVER 1 2 323 341 LAMP CAP 1 3 323 339 LAMP 100V 9W 1 4 MAIN BODY 1 ...

Страница 13: ......

Отзывы: