--- 13 ---
8-4. Tightening Torque
(1) Tapping Screws (W/Flange) D4
[40] [48] <40> <48> ................................
1.5 to 2.5 N
•
m (15 to 25 kgf
•
cm)
(2) Tapping Screws D5
[7] [15] [19] <7> <15> <19> ......................................
2.4 to 3.4 N
•
m (25 to 35 kgf
•
cm)
(3) Machine Screw (W/Washer) M3.5 x 6
[29] <29> .......................................
0.45 to 0.75 N
•
m (4.5 to 7.5 kgf
•
cm)
8-5. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength:
AC 2,500 V for 1 minute, with no abnormalities .............. 110 V --- 127 V
AC 4,000 V for 1 minute, with no abnormalities .............. 220 V --- 240 V
8-6. No-load Current Values
After no-load operation for 30 minutes, the no-load current values should be as follows.
Voltage (V)
Current (A) max.
110
3.7
120
3.5
220
1.8
230
1.8
240
1.7
Содержание S 15SB