![Hitachi RAS/C-L40GHZ Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/hitachi/ras-c-l40ghz/ras-c-l40ghz_installation-manual_2139531007.webp)
1.
,
According to the specific situation the indoor and outdoor connecting pipe can pass through the
corresponding pipe hole in the left right or back panel of the indoor unit The pipe hole must be
,
.
equipped with protection ring
.
2.
,
Please remove the maintenance panel of indoor unit before connecting the indoor and outdoor pipe
see
ndoor wiring for details
"
.
i
"
Installation for indoor draining pipe
(1)
(
Connect the draining pipe the attached indoor draining pipe can
be used with the water outlet
)
.
(2)
The draining pipe should be inclining from inside to outside to
facilitate the draining of condensed water
.
(3)
Please apply the attached adhesive to the connecting area of
draining pipe to avoid leaking see figure
,
11.
(4)
,
Depending on the actual situation the piping can pass through the
hole of either the back left or right panel when installing
,
.
(5)
Check the draining pipe installed as per requirement to make sure
that it works efficiently
.
1 Inspection before wiring
(1)
(
,
,
,
.)
Check whether the electrical part master power switch fuse wire terminal etc is in line with the requirement
on the nameplate of unit
.
(2)
Check and make sure that the difference between supply voltage and rated voltage is within
of rated
voltage
.
2 Apply the separate power supply with separate circuit breaker see figure
,
12.
3 The earthing should be safe reliable and correct
,
.
4 Refer to table
for details of electrical parameters
3
.
Installation for Draining Pipe
Note
:
Adhesive
Draining pipe
Figure
11
Figure
12
Power supply for
indoor unit
Power supply for
outdoor unit
Earthing
Indoor
unit
Connecting wire for
indoor outdoor unit
/
Master switch
/
fuse installed by
(
customer
)
Power
supply
Outdoor unit
Power
supply
5
Breaker
Breaker
Wiring
10%