background image

Do

 

not

 

operate

 

the

 

system

 

until

 

all

 

the

 

check points

 

have

 

been

 

cleared

.

(A) Check

 

to

 

ensure

 

that

 

the

 

stop

 

valves

 

of the

 

outdoor

 

unit

 

are

 

fully

 

opened.

(B) Check to ensure that the electric wires have been fully connected.
(C) Check to ensure that the electrical resistance is more than 2M

Ω

, by measuring

 

the

 

resistance

 

between ground

 

      

and the

 

terminal

 

of

 

the

 

electrical parts

If

 

not

do

 

not

 

operate

 

the

 

system until

 

the

 

electrical

 

leakage

 

is

 

found

 

and 

      repaired

.

Trial run function identification
Turn ON the appliance to proceed trial run.
Pay

 

attention

 

to

 

the

 

following

 

items

 

while the

 

system

 

is

 

running

.

Do not touch any of the parts by hand at the discharge gas side

since the compressor chamber and the pipes at the

 discharge side are heated higher than 194

℉ (

90

℃).

 

T

rial run should be performed after refrigerant piping,drain,wiring,etc. have been finished.

The air conditioner is provided with a crankcase heater, check to ensure that the switch on the main 
power source has been ON for more than 6 hours ahead of power on preheating, otherwise it might 
damage the compressor!

·

Turn off the power

 

after trail run is finished.

Installation of the appliance is generally finished after the above operations are done. If you still have any trouble, 
please contact local technical service center of our company for further information.

CAUTION

Installation instructions

Trial

 

Run

11

NOTE

(1)

 Follow local codes and regulations when selecting field wires, and all the above are the minimum wire size.

(2) Use copper supply wires.
(3) When the transmitting cable is longer than 49 ft. (15m) ,  a larger wire size should be selected.

(4) Install

 

main

 

switch

 

and

 

ELB

 

for

 

each

 

system

 

separately

Select

 

the

 

high

 

response

 

type

 

ELB

 

that is

 

acted

 

within

 

      0

.

1second

.

Electrical Data 

Max. Running Current (A): REFER TO NAMEPLATE

1. When connecting the terminal block using stranded wire, make
    sure to use the round crimp-style terminal for connection to the 
    power supply terminal block. Place the round crimp-style  
    terminals on the wires up to the covered part and secure in place.

2

.

 When connecting the terminal block using a single core wire, be 

    sure to perform curing.

<Attentions

 

when

 

Connecting the Power Supply Wiring>

 

Model

Power Supply

ELB

Power Source 

Cable Size

Transmitting 

Cable Size

Fuse or 

Circuit 

Breaker (A)

Rated Current 

(A)

Nominal Sensitive 

Current (mA)

1.0HP(9K)

208/230V ~/60Hz

15

30

3×14AWG

4×16AWG

15

1.5HP(12K)

208/230V ~/60Hz

20

30

3×14AWG

4×16AWG

20

2.0HP(18K)

208/230V ~/60Hz

20

30

3×12AWG

4×16AWG

20

3.0HP(24K)

208/230V ~/60Hz

35

30

3×12AWG

4×16AWG

35

4.0HP(36K)

208/230V ~/60Hz

45

30

3×10AWG

4×16AWG

45

Single core wire

Terminal

Round crimp-style terminal

Stranded wire

Covered part

Содержание RAS-1.0PNNBDH1

Страница 1: ... RAS 1 0PNNBDH1 RAS 1 5PNNBDH1 RAS 2 0PNNBDH1 RAS 3 0PNNBDH1 RAS 4 0PNNBDH1 OUTDOOR UNITS DC INVERTER SERIES HO2021388HA ...

Страница 2: ... is designed for the following temperatures It should be operated within this range DC Inverter Unitary Series Mode Outdoor Operation Temperature Range Model Maximum Minimum Cooling Operation 1 0 4 0HP 9K 36K 118 48 5 15 Heating Operation 3 0HP 24K 75 24 13 25 1 0 1 5 2 0 4 0HP 9K 12K 18K 36K 75 24 4 20 Storage Condition Temperature 13 140 25 60 Humidity 30 80 The numbers in the model represent th...

Страница 3: ...tance with no connection and don t connect multiple devices to the same AC power supply Otherwise it may result in bad contact poor insulation unallowable current which could finally result in fire or electric shock After all installations are completed check to make sure that no refrigerant leakage occurs It will generate harmful substances if the refrigerant gas leaks in the interior area and ha...

Страница 4: ...onditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be installed in accordance with national wiring regulations Servicing shall only be performed as recommended by the equipment manuf...

Страница 5: ...hanger EEV Service valve Electrical Wiring Diagram Refrigerant Flow Diagram Outdoor Unit Indoor Unit Terminal Terminal Power Supply Power Connecting Cord 1 0 1 5 2 0 3 0 4 0HP 9K 12K 18K 24K 36K SI SI L L N N L2 L1 NOTE Since there may be differences in some models terminal blocks wiring connection should be done according to letters on the terminal block Please disregard numbers in this case ...

Страница 6: ...required for the affected device Install the unit horizontally Please install it in an area not affected by snowfall or blowing snow In areas with heavy snow please install a canopy a pedestal and or some baffle boards Avoid the following places for installation where air conditioner trouble is liable to occur Where there is much machine oil Salty places such as seaside Where sulfide gas is genera...

Страница 7: ... avoid disturbing neighbors and to protect the environment it is necessary to install a drainage elbow and a drain hose to drain out the condensate water Please do the drainage work before the indoor unit and outdoor unit are connected Otherwise it will be difficult to install drainage elbow after the machine becomes immovable Connect the drain hose field supplied nside diameter i 5 8 in 15mm as s...

Страница 8: ...itional refrigerant charge L 24 6 0 161 oz ft For 2 0 4 0HP 18K 36K Additional refrigerant charge L 24 6 0 376 oz ft Refrigerant Piping Model Outer Diameter of Pipe in mm Gas Liquid 1 0 1 5HP 9K 12K ø3 8 ø9 52 ø1 4 ø6 35 2 0HP 18K ø1 2 ø12 7 ø1 4 ø6 35 3 0HP 24K ø ø15 88 5 8 ø ø9 52 3 8 4 0HP 36K ø ø19 05 3 4 ø ø9 52 3 8 Pipe Length L Height Difference H Indoor Unit Outdoor Unit 3 Piping thickness...

Страница 9: ... Good o 90 Burr Copper pipe Spare reamer Pipe cutter Flare nut Copper pipe Flaring tool Clutch type Wing nut type Die Copper pipe Flare nut Copper pipe Die York Smooth all around Inside is shining without any scratches 4 Piping Connection 1 Confirm that the valve is closed 2 Connect the indoor unit and the outdoor unit with field supplied refrigerant piping Suspend the refrigerant piping at certai...

Страница 10: ... cover Using piping tape apply taping starting from the entry of outdoor unit Fix the end of piping tape with adhesive tape When piping has to be arranged through above ceiling closet or area where temperature and humidity are high wind additional commercially sold insulation for prevention of condensation 5 Air Tight Test Clamp field supplied Insulation field supplied Refrigerant pipe field suppl...

Страница 11: ...rotect the wires electrical parts etc from rats or other small animals If not protected rats may gnaw at unprotected parts and at the worst a fire will occur Avoid the wiring from touching the refrigerant pipes plate edges and electrical parts inside the unit If not do the wires will be damaged and at the worst a fire will occur Install an ELB Electric Leakage Break in the power source If ELB is n...

Страница 12: ...nd the transmitting cable to the conduit holder using the lock nut 3 Connect the power supply cable and the transmitting cable to terminal 4 Fasten the power supply cable and the transmitting cable with the cable clamp 5 Be sure to seal the holes when applying the putty Place the cables side to side Do not overlap the cables 6 Put the wiring distribution cover back after completion of the work Loc...

Страница 13: ...e any trouble please contact local technical service center of our company for further information CAUTION Installation instructions Trial Run 11 NOTE 1 Follow local codes and regulations when selecting field wires and all the above are the minimum wire size 2 Use copper supply wires 3 When the transmitting cable is longer than 49 ft 15m a larger wire size should be selected 4 Install main switch ...

Страница 14: ......

Страница 15: ......

Страница 16: ...ithout notice in order that Hitachi Johnson Controls Air Conditioning Inc may bring the latest innovations to their customers 2021 Johnson Controls Air Conditioning Inc Hitachi 2021 03 Version A Printed in China Hitachi Johnson Controls Air Conditioning Inc ...

Отзывы: