– 44 –
Power
Unit 1
Unit 2
Unit 3
Unit 5
Operation
Rush-in prevention
Power
Outdoor fan
Compressor
rotation speed
Turns on
for heating
Compressor requirement
Power relay
Reversing
valve
Cooling
Cooling
Cooling
Unit 3
Cooling
Cooling
1S 1S
1S
100ms
100ms
520
Unit 1
Unit 2
Expansion valve
Unit 3
Unit 4
480
0
520
480
0
520
480
0
520
480
0
Initialization
Power
Power
Power
Power
Power
Start sequence
Target speed
Step up control
[SDSTEP]min
—1
/[TSKSPT] sec
[TSKTM1_C
*
]
[SDRCT1_C
*
]
[PSTARTC3
*
]
<TD c N compen Diving control >
[PSTARTC3
*
]
[PSTARTC3
*
]
[PSTARTC3
*
]
Steady speed period
100ms
520
Unit 5
480
0
Initialization
[PSTARTC3
*
]
<TD c N compen Diving control >
<TD c N compen Diving control >
<TD c N compen Diving control >
<TD c N compen Diving control >
TSKTM1, SDRCT1, SDSTEP, TSKSPT, CMAX2, PSTART and PSTARTH are EEPROM data.
MODEL RAM-90QH5
◆
◆
Expansion valves
• The expansion valves are initialized when power is supplied. The valve for unit 1 is fully closed (–520
pulses), and then that for unit 2 is fully opened (480 pulses). The valve for unit 2 is fully closed (–520
pulses), and then that for unit 3 is fully opened (480 pulses). The valve for unit 3 is fully closed (–520
pulses), and then that for unit 4 is fully opened (480 pulses). The valve for unit 4 is fully closed (–520
pulses), and then that for unit 5 is fully opened (480 pulses). When the valve for unit 1, 2, 3, 4, 5 is fully
closed (0 pulse), start-up is possible.
• The start openings are held during the steady speed period when the compressor is started. After the
steady speed period is finished, the TD control is entered. The start openings are set to PSTARTH when
the outdoor temperature at start 40
°
C or more, and to PSTART when it is less than 40
°
C. PSTART C3 is
used for 3 rooms and 4 rooms operation.
◆
◆
Compressor rotation speed
• When the compressor is started, the SDRCT1 speed / TSTKTM1 second is held. (Steady speed period)
After the steady speed period is finished, the speed increases at the rate of SDSTEP speed / TSKSPT
second until the target speed is reached.
Содержание RAM-90QH5
Страница 13: ... 12 ...
Страница 14: ... 13 ...
Страница 15: ... 14 ...
Страница 19: ... 18 BASE DRAIN PIPE A DRAIN PIPE BUSH 100 mm ABOVE 10 11 ...
Страница 21: ... 20 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAM 90QH5 Service space ...
Страница 26: ...CIRCUIT DIAGRAM MODEL RAM 90QH5 27 ...
Страница 28: ... 31 ...
Страница 31: ... 37 ...
Страница 32: ... 39 ...
Страница 33: ... 41 ...
Страница 34: ... 43 ...
Страница 36: ... 45 90 23 ...
Страница 42: ... 51 REFRIGERATING CYCLE DIAGRAM MODEL RAM 90QH5 ...
Страница 51: ... 60 3 System power Module Circuit ...
Страница 60: ... 69 Electric expansion valve thermistor NARROW PIPE 5 5 5 5 8 8 8 ...
Страница 72: ... 85 ...
Страница 76: ... 90 Lighting mode self diagnosis lamp Location of self diagnosis lamp 1 RAM 90QH5 ...
Страница 77: ... 91 Lighting mode self diagnosis lamp 2 RAM 90QH5 ...