CONDENSED WATER DISPOSAL OF OUTDOOR UNIT

Á

 

There are holes on the base of Outdoor unit for condensed 
water to exhaust.

Á

 

In order to 

ß

 ow condensed water to the drain, the unit is 

installed on a stand or a block so that the unit is 100mm 
above the ground as shown 

Þ

 gure. Join the drain pipe to 

one hole.

Á

 

At 

Þ

 rst insert one portion of the hook to the base (Portion A), 

then pull the drain pipe in the direction shown by the arrow 
while  inserting  the  hook  into  the  base. After  installation, 
check whether the drain pipe cling to the base 

Þ

 rmly.

When Using and Installing In Cold Areas 

When the air conditioner is used in low temperature and in 
snowy conditions, water from the heat exchanger may freeze 
on the base surface to cause poor drainage. When using the 
air conditioner in such areas, do not install the bushings. Keep 
a minimum of 250mm between the drain hole and the ground. 
When using the drain pipe, consult your sales agent.

    For more details, refer to the installation Manual for Cold 
Areas.

WARNING  ........  Incorrect  methods  of  installation  may  cause  death  or  serious  injury.
CAUTION  .........  Improper  installation  may  result  in  serious  consequence.
Make  sure  to  connect  earth  wire.
This  sign  in  the 

Þ

 gures  indicates  prohibition.

 

Be sure to tighten the 

ß

 are nut to the speci

Þ

 ed torque using a torque wrench. If the 

ß

 are nut is tightened excessively, it may 

crack  as  time  elapses,  cause  refrigerant  leakage.

!

!

SPLIT  UNIT  AIR  CONDITIONER 

INSTALLATION  MANUAL

 

 

 

Outdoor  Unit 

RAM-70NP4A

( M a r k       i s   e x c l u s i v e   u s e   t o o l   f o r   R 4 1 0 A )

    +    –    Screwdriver   

  Measuring  Tape   

  Knife   

 Saw  

 ø 65mm Power Drill  

 Hexagonal Wrench Key 

(          4mm)   

  Wrench  (14,  17,  22,  26mm)              Gas 

Leakage Detector 

 Pipe Cutter   

 Putty   

 Vinyl Tape   

 

  Pliers     

  Flare  Tool                Vacuum  Pump Adapter       

        Manifold  Valve          Charge  Hose          Vacuum  Pump 

 

  Carefully  read  through  the  procedures  of  proper 

installation  before  starting  installation  work.

  The sales agent should inform customers regarding 

the  correct  operation  of  installation.

SAFETY  PRECAUTION

  Read  the  safety  precautions  carefully  before  operating  the  unit.

  The  contents  of  this  section  are  vital  to  ensure  safety.  Please  pay  special  attention  to  the  following  sign.

WARNING

!

CAUTION

!

 

A  circuit  breaker  must  be  installed  in  the  house  distribution  box  for  the  direct  connected  power  supply  wire  to  the  outdoor 
unit.  In  case  of  other  installations  a  main  switch  with  a  contact  gap  or  more  than  3.5mm  has  to  be  installed.  Without  a

 

circuit  breaker,  the  danger  of  electric  shock  exists.

 

Please  request  your  sales  agent  or  quali

Þ

 ed  technician  to  install  your  unit.  Water  leakage,  short  circuit  or 

Þ

 re  may  occur  if 

you  do  the  installation  work  yourself.

FOR  SERVICE  PERSONNEL  ONLY

Tools Needed For Installation Work

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the  unit  as  described  in  the  user’s  guide.

  Unauthorized  modi

Þ

 cations  to  the  air  conditioner  may  be  dangerous.  If  a  breakdown  occurs  please  call  a  quali

Þ

 ed  air 

conditioner  technician  or  electrician.  Improper  repairs  may  result  in  water  leakage,  electric  shock  and 

Þ

 re,  etc.

 

Be  sure  to  connect  the  earth  wire  from  the  power  supply  wire  to  the  outdoor  unit  and  between  the  outdoor  and  indoor 
unit.  Improper  earthing  may  cause  electric  shock.

  Please  observe  the  instructions  stated  in  the  installation  manual  during  the  process  of  installation.  Improper  installation  may 

cause  water  leakage,  electric  shock  and 

Þ

 re.

  Make  sure  that  the  units  are  mounted  at  locations  which  are  able  to  provide  full  support  to  the  weight  of  the  units.  If  not, 

the  units  may  collapse  and  impose  danger.

  Observe  the  rules  and  regulations  of  the  electrical  installation  and  the  methods  described  in  the  installation  manual  when 

dealing  with  the  electrical  work.  Use  power  cables  approved  by  the  authorities  of  your  country.

  Be  sure  to  use  the  speci

Þ

 ed  wire  for  connecting  the  indoor  and  outdoor  units.  Please  ensure  that  the  connections  are  tight 

after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating 
and 

Þ

 re.

  Please use the speci

Þ

 ed components for installation work. Otherwise, the units may collapse or water leakage, electric shock 

and 

Þ

 re  may  occur.

  Be  sure  to  use  the  speci

Þ

 ed  piping  set  for  R-410A.  Otherwise,  this  may  result  in  broken  copper  pipes  or  faults.

  When installing or removing an air conditioner, only speci

Þ

 ed refrigerant (R410A) shall be allowed, do not allow air or moisture 

to  remain  in  the  refrigeration  cycle.  Otherwise,  pressure  in  the  refrigeration  cycle  may  become  abnormally  high  so  that  a 
rupture  may  be  caused.

  Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with 

Þ

 re, a poisonous 

gas  may  occur.

  After  completion  of  installation  work,  check  to  make  sure  that  there  is  no  refrigeration  gas  leakage.  If  the  refrigerant  gas 

leaks  into  the  room,  coming  into  contact  with 

Þ

 re  in  the  fan-driven  heater,  space  heater,  etc.,  a  poisonous  gas  may  occur.

 

Do  not  install  the  unit  near  a  location  where  there  is 

ß

 ammable  gas.  The  outdoor  unit  may  catch 

Þ

 re  if 

ß

 ammable

 

gas  leaks  around  it. 

 

Please  ensure  smooth 

ß

 ow  of  water  when  installing  the  drain  hose.

 

An  IEC  approved  power  cord  should  be  used.  Power  cord  type:  NYM.

THE  CHOICE  OF  MOUNTING  SITE 

  (Please  note  the  following  matters  and  obtain  permission  from  customer  before  installation).

WARNING

!

 

The Outdoor unit must be mounted at a location which can support heavy weight. Otherwise, noise and vibration will increase.

CAUTION

!

 

Do  not  expose  the  unit  under  direct  sunshine  or  rain.  Besides,  ventilation  must  be  good  and  clear  of  obstruction.

 

The  air  blown  out  of  the  unit  should  not  point  directly  to  animals  or  plants.

 

The  clearances  of  the  unit  from  top,  left,  right  and  front  are  speci

Þ

 ed  in 

Þ

 gure  below.  At  least  3  of  the  above  sides  must  be 

open  air.

 

Be  sure  that  the  hot  air  blown  out  of  the  unit  and  noise  do  not  disturb  the  neighbourhood.

 

Do  not  install  at  a  location  where  there  is 

ß

 ammable  gas,  steam,  oil  and  smoke.

 

The  location  must  be  convenient  for  water  drainage.

 

Place the Outdoor unit and its connecting cord at least 1m away from the antenna or signal line of television, radio or telephone. 
This  is  to  avoid  noise  interference.

Names  of  Outdoor  Components

Drain  Pipe

1

Dimension  of  Mounting  Stand

of  the  Outdoor  unit

(unit:  mm)

Figure  showing  the  Installation  of  Outdoor  Unit.

3

Bush

Qty

No.

Item

Bush

1

10

11

12

Height difference

Height difference between indoor units should 
be not more than 5m.

Piping length

(L1 + L2 + L3 + L4) = Maximum 60m

Minimum piping length for each indoor unit is 5m.

Maximum piping length for one indoor unit is 25m.

        In  case  the  pipe  length  is  more  than  30m,  add 
refrigerant R410A at 20 gram per every meter exceeds.

Á

 

Mount  the  Outdoor  unit  on  stable  ground  to  prevent  vibration  and 
increase  of  noise  level.

Á

 

Decide the location for piping after sorting out the different types of 
pipe  available.

Flare adaptor for piping

The 

ß

 are adaptor for piping is required 

depending on combination of indoor units.

  ø9.52 (3/8”) 

 ø 12.7 (1/2”)

 

Parts number TA261D-4 001

  ø12.7(1/2”) 

 ø 9.52 (3/8”)

 

Parts number TA261D-6 002

One unit of 1.8kW, 2.5kW, 3.5kW or 5.0kW

One unit of 1.8kW, 2.5kW, 3.5kW or 5.0kW
(5kW  unit:  Optional  flare  adaptor  for  piping  is 
necessary.)

One unit of 1.8kW, 2.5kW, 3.5kW or 5.0kW
(5kW  unit:  Optional  flare  adaptor  for  piping  is 
necessary.)

One unit of 1.8kW, 2.5kW, 3.5kW or 5.0kW
(2.5kW, 3.5kW unit: Optional 

ß

 are adaptor for piping 

is necessary.)

Á

 

When removing side cover, pull the handle 
after  releasing  the  hook  by  pulling  it 
downward.

Á

 

To  the  outdoor  unit,  up  to  four  indoor  units  can  be  connected  until 
the  total  value  of  each  units’s  capacity  reaches  11  kW.

Á

 

The pipe connection ports of the outdoor unit and connectable indoor 
units  are  shown  above.

[Outdoor unit installation]

CAUTION

●   

Make  sure  to  connect 
to  two  or  more  indoor 
units.

!

If  you  wish  to  prepare  the  copper  tubes  and  insulation  material  in  the 

Þ

 eld,  we  recommend  the  following.

No.

Material

Speci

Þ

 cation

1

Cooper  tube

Deoxidized  annealed  copper  pipe  with  6.35mm  O.D.,  0.8mm  wall  thickness.

4.0kW  or  less

Small  dia.

Deoxidized  annealed  copper  pipe  with  9.52mm  O.D.,  1.0mm  wall  thickness.

Large  dia.

Deoxidized  annealed  copper  pipe  with  6.35mm  O.D.,  0.8mm  wall  thickness.

Small  dia.

Deoxidized  annealed  copper  pipe  with  12.7mm  O.D.,  1.0mm  wall  thickness.

Large  dia.

5.0kW  or  more

2

Flare  nut

Flare  nuts  with  6.35mm  O.D..

4.0kW  or  less

Small  dia.

Flare  nuts  with  9.52mm  O.D..

Large  dia.

Flare  nuts  with  6.35mm  O.D..

Small  dia.

Flare  nuts  with  12.7mm  O.D..

Large  dia.

5.0kW  or  more

3

Insulation  for  refrigerating  pipe

Foamed  polyethylene  insulation  pipe  which  does  not  corrode  the  copper  tube.

●   

Large  dia.  pipe  side:  15mm  I.D..,  8mm  wall  thickness.

●   

Small  dia.  pipe  side:  8mm  I.D.,  7mm  wall  thickness.

4

Connecting  cord

Refer  to  item  3.3.

5

Vinyl  tape

6

Sealer  (Putty)

7

Refrigerator  oil

8

Bushing  for  refrigerating  pipes

1.  Proper place for installation

1.1  Outdoor unit

 

(1) Keep the space around the unit for maintenance and avoiding the effects of hindrance for normal ventilation of the unit.

 

(2) The northern or eastern side of the building is better to install. At the installation on the southern or western side unavoidably, some blind

 

 

should be set up for the unit. (In this case, the blind must not obstruct the ventilation of the unit.)

 

(3) You’d better not put the unit at a place where is full of dirt and at a place where is wet in the rain.

 

(4) Place as near as possible to the indoor unit.

 

(5) Install the unit in a stable place to minimize vibration or noise.

 

(6) After arranging the cords and pipes, secure them in place.

WARNING

 

If you cannot attach the side cover due to the connecting cord, press the connecting cord in direction to the front panel 
to 

Þ

 x  it.

 

Be sure that the hooks of the side cover is 

Þ

 xed in certainly. Otherwise water leakage may occur and this causes short 

circuit  or  faults.

 

The  connecting  cord  should  not  touch  to  service  valve  and  pipes.  (It  becomes  high  temperature  in  heating  operation.)

 

This  appliance  must  be  earthed.

 

Power  is  supplied  through  outdoor  unit,  do  not  connect  power  source  to  indoor  unit.

Wiring  of  The  Outdoor  Unit

  Please  remove  the  side  cover  for  wire  connection.

!

WARNING

!

  The  naked  part  of  the  wire  core  should  be  10  mm  and 

Þ

 x  it  to  the  terminal  tightly.  Then  try  to  pull  the  individual  wire  to  check  if  the  contact 

is  tight.  Improper  insertion  may  burn  the  terminal.

 

Be  sure  to  use  only  power  cables  approved  from  the  authorities  in  your  country.  For  example  in  Germany:  Cable  type:  NYM  3x1.5mm

2

.  (fuse 

=  16A  time  delay)

 

Please  refer  to  the  installation  manual  for  wire  connection  to  the  terminals  of  the  units.  The  cabling  must  meet  the  standards  of  electrical 
installation.

 

There  is  a AC  voltage  of  220-240V  between  the  L  and  N  terminals. Therefore,  before  servicing,  be  sure  to  remove  the  plug  from  the AC  outlet 
or  switch  off  the  main  switch.

2.

 

In the electrical installation a separator with a contact gap of more than

 

3mm has to be installed. During cleaning or service the set has to be

 

switched off with this separator.

3.  Installation procedure and notice

 

Especially,  the  selection  of  installation  place  need  great  care  for  the

 

split type air conditioner, because it is very dif

Þ

 cult to move from place

 

to place after the 

Þ

 rst installation.

3.1  Wiring

 

(1) Connect the electrical wiring between the Indoor and Outdoor unit,

 

 

as shown in Fig. 3-1. Never connect the wiring by mistake.

 

 

In case of wrong connection, the unit does not operate properly

 

 

and  it  may  cause  malfunction.

 

(2) The connecting cord must be 

Þ

 xed by the band which is located

 

 

near the terminal board.

3.3  Checking  for  the  electric  source  and  the  voltage  range

  Before installation, the power source must be checked and necessary wiring work must be completed. To make the wiring capacity  proper, 

use  the  wire  gauges  list  below  for  the  lead-in  from  a  pole  transformer  and  for  the  wiring  from  a  switch  board  of  fuse  box  to  the  main 
switch  and  outdoor  unit  in  consideration  of  the  locked  rotor  current.

  Investigate  the  power  supply  capacity  and  other  electrical  conditions  at  the  installation  location.

  Depending  on  the  model  of  room  air  conditioner  to  be  installed,  request  the  customer  to  make  arrangements  for  the  necessary  electrical
  work  etc.
  The  electrical  work  includes  the  wiring  work  up  the  outlet.  In  localities  where  electrical  conditions  are  poor,  use  of  a  voltage  regulation  is
  recommended.

Fuse  Capacity

30A  time  delay  fuse

Bind connecting cords to make them

Þ

 t  between  the  convex  sections.

Grounding  rod  (optional)
(Earth  wire  and  grounding  rod  are  not  supplied.  Please  use  optional  items  below.)

Earth  line

  IMPORTANT

Fig. 3-2

3.2  Connection of the connecting cords and power cord

 

(1) Cut  off  the  connecting  cord,  the  power  cord  and  strip  the

 

 

insulation of the wire, as shown in Fig. 3-2.

 

(2) Connect the connecting cord and power cord to the terminal

 

 

board. (Fig. 3-3)

 

(3) Fix  the  connecting  cords  and  power  cord  with  steel  band

 

 

certainly. (Fig. 3-3)

WARNING

!

Type  of  grounding  rod

SP-EB-2

Length

900mm

Cable  length

up  to 

1

6m

up  to  15m
up  to  25m

Wire  cross-section

1.5mm

2

2.5mm

2

4.0mm

2

IMPORTANT

WARNING

●   

Connect  the  Connecting  Cord  to  C1  and  D1  “Indoor  1”  for  indoor  unit 
1,  C2  and  D2  “Indoor  2”  for  indoor  unit  2,  C3  and  D3  “Indoor  3”  for 
indoor  unit  3,  C4  and  D4  “Indoor  4”  for  indoor  unit  4.

!

Fig. 3-1

<

IA894:  A 

>

Arrange power cord so they do 
not  touch  service  valve.

CAUTION

!

Fig. 3-3

Face  this  side  (suction  side)  of 
the  unit  to  the  wall.

Remove  side  cover 
when  connecting  the 
piping  and  connecting 
cord.

Pull  downward

BASE

DRAIN  PIPE

Procedures  of  Wiring

Note:

  Outdoor  supply  cords  shall  not 

be  lighter  than  polychloroprene 
sheathed 

ß

 exible cord with code 

designation  60245  IEC  57.

!

CAUTION