– 63 –
FORCED COOLING
●
In order to accumulate refrigerant, units operate in cooling cycle.
Execution condition and operation status are shown below.
[Execution condition]
●
With neither indoor unit 1 and 2 not operated, when forced cooling switch is turned ON, forced cooling will
be performed.
●
Always operation status of indoor unit are monitored and forced cooling is inhibited when operation of any
unit is detected.
[Operation status]
●
Outdoor unit fan: Fixed in LO.
●
Compressor rotation speed: Fixed in 3900min
-1
.
[Note]
●
During forced cooling, if failure occurs in outdoor unit, thermostat is turned off. However, it is not counted.
●
Since rotation speed of compressor is fixed in 3900min
-1
during forced cooling, compressor fixed speed
control at start is not performed.
The following shows the operation state of forced cooling.
Power
Power
In-rush Prevention
Approx 100ms
31.25PPS
Hold 500ms
Hold 500ms
Initialization finished
TSKTM1
3900rpm
Balancing period 3min.
15sec. + sub
80sec.
100ms
Service switch
Heating output
Cooling output
Outdoor fan
Turns on
for Heating
Operation
Unit 1
Unit 2
Unit 1
Compressor
rotation speed
Main microcomputer
Electric expansion valve
Power relay
Compressor
Reversing
valve
Unit 2
1sec
1sec
1sec
Lo
Forced cooling request
Balancing request
Forced cooling request
Balancing request
520
480
0
520
480
0
[Outdoor temperature<40
°
C]
[Outdoor temperature<40
°
C]
PSTART
PSTART
<TD c
3
N compen Diving control>
<TD c
3
N compen Diving control>
❈
●
TSKTM1 and PSTART are EEPROM data.
Содержание RAM-50CNHZ2
Страница 41: ... 40 WIRING DIAGRAM MODEL RAM 50CNHZ2 OUTDOOR UNIT ...
Страница 47: ... 51 BASIC MODE MODEL RAM 50CNHZ2 ...
Страница 50: ... 57 ...
Страница 51: ... 59 ...
Страница 102: ... 110 PARTS LIST AND DIAGRAM MODEL RAS 20CNHZ2 11 2 18 8 20 12 63 1 4 60 3 7 14 15 6 5 16 13 88 61 17 9 62 10 ...
Страница 104: ... 112 MODEL RAS 30CNHZ2 8 12 23 1 3 5 60 14 4 7 6 13 61 61 11 62 35 12 10 9 17 2 63 18 19 15 16 ...