– 51 –
(2) During ON
●
The drain current at IC1 increase linearly. During this period, the gate voltage and current become
constant because of the saturation characteristics of the transformer.
(3) Shifting from ON to OFF
●
This circuit applies a negative feedback signal from the 12V output. When the voltage across C708
reaches the specified value, REG2 turns on and current flows to PQ8
1
-
2
. This turns the secondary
circuits on, sets IC1 pin
1
to “Hi”, and turns IC1 off.
(4) During OFF
●
While IC1 is on, the following energy charges the primary windings of the transformer:
Energy = LI
2
/2. Here,
L : Primary inductance
I : Current when IC1 is off
This energy discharges to the secondary windings during power off. That is, C707-C710, C718 is
charged according to the turn ratio of each winding.
●
At the start, an overcurrent flows to IC1 because of the charged current at C707-C710, C718.
●
The drain current at IC1 generates a voltage across R716. If it exceeds the IC1 base voltage, it sets
the IC gate voltage to “HI”.
●
R716 limits the gate voltage to prevent excessive collector current from flowing to IC1.
●
This SW power circuit uses a frequency as low as 20kHz, especially at a low load (when both the
indoor and outdoor units stop): This reduces power loss in standby status.
<Reference>
If the power circuit for P.W.B. seems to be faulty:
(1) Make sure that 5V, 12V, 15V, 17V and -5V on the control P.W.B. power voltage are the specified values.
(2) When only the 5V output is low:
REG 1 (regulator) faulty, 5V-0V shorted, output is too high, or REG 1 is abnormal.
(3) When 12V and 5V are abnormal:
The following defects can be considered:
1
Fan, operation, power, rush prevention relay (shorting in relay, etc.)
2
REG 1 (regulator is abnormal), etc.
Shorting on primary circuits.
When shorting occurs in the secondary circuits, there is no abnormality in the primary circuits because
of overcurrent protection.
The voltage rises when an opening occurs in the primary circuits, or the feedback system is abnormal.
(4) When 15V/17V power supply is abnormal:
D710, D713 or drive circuit is abnormal.
(5) When all voltage are abnormal:
IC1, R716, may possibly be defective. Also D cable may possibly be reverse connected.
❈
If IC1 is abnormal, be aware that other components, such as the power module, REG (regulator), etc.
are possibly defective.
[When the switching power supply seems to be abnormal, the voltage between IC1 pin
4
(to be measured at
the leads of R202 and R201) and IC1 pin
5
(to be measured at R216 lead) may be between 11 and 16V.
This is because the protection circuit of IC1 is operating.]
Содержание RAM-18QH5E
Страница 9: ... 8 ...
Страница 10: ... 9 RAM 18QH5E MODEL RAM 18QH5E ...
Страница 11: ... 10 ...
Страница 12: ... 11 AC 220V 240V ONLY L N INDOOR 1 C1 D1 C2 D2 INDOOR 2 RAM 18QH5E ...
Страница 13: ... 12 RAM 18QH5E ...
Страница 21: ... 20 MODEL RAM 18QH5E WIRING DIAGRAM OUTDOOR UNIT ...
Страница 23: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAM 18QH5E 23 MOUNTING PCB SET TYPE ...
Страница 25: ... 27 heating ff BASIC MODE MODEL RAM 18QH5E ...
Страница 28: ... 33 Table 6 Table 7 ...
Страница 29: ... 35 ...
Страница 31: ... 37 ...
Страница 56: ... 62 Fig 11 2 ...
Страница 69: ... 75 1 Outdoor unit does not operate remote control signal can be received RAM 40QH5 ...
Страница 71: ... 77 Lighting mode self diagnosis lamp 2 RAM 18QH5E ...
Страница 72: ... 78 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 73: ... 79 ...
Страница 74: ... 80 ...
Страница 75: ... 81 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 18QH5E ...
Страница 78: ...HITACHI PM NO 0276E Printed in Malaysia RAM 18QH5E ...