Installation diagram
Installation must be performed in accordance with the
national wiring standards by authorized personnel only.
Above figure is only a simple presentation of the unit, it may
not match the external appearance of the unit you purchased.
air outlet distance from the wall
should be over 500mm
Distance from ceiling
over 200 mm
should be
Distance from the obstacle
should be over 3000mm.
Distance from floor
over 2500mm.
should be
Distance from wall
should be over
50mm
Distance from
the wall
be over 50mm
should
Distance from the
obstacle should be
over 500mm.
Air intake distance
from
the wall
should be
over 250mm
Air intake
distance from
the wall
should be
over 250mml
over 250mm
Installation instructions
3
Select the installation locations
Location for Installing Indoor Unit
1. Where there is no obstacle near
the air outlet and air can be easily
blown to every corner.
2. Where piping and wall hole can
be easily arranged.
3. Keep the required space from
the unit to the ceiling and wall
according to the installation
diagram on previous page.
4. Where the air filter can be easily
removed.
5. Keep the unit and remote controller 1m or more
apart from television, radio etc.
6. Keep as far as possible from fluorescent lamps.
7. Do not put anything near the air inlet to obstruct it
from air absorption.
8. Install on a wall that is strong enough to bear the
weight of the unit.
9. Install in a place that will not increase operation
noise and vibration.
10. Keep away from direct sunlight and heating
sources. Do not place flammable materials or
combustion apparatuses on top of the unit.
Pipe length
is 15 meters
Max.
Height should
be less than 5m
Indoor unit
Outdoor
unit
Location for Installing Outdoor Unit
1. Where it is convenient to install and well ventilated.
2. Avoid installing it where flammable gas
could leak.
3. Keep the required distance
apart from the wall.
The pipe length between indoor and
outdoor unit should be not more than
5 meters in factory default status, but it
can go up to maximum 15 meters with
additional refrigerant charge.
6. Keep the outdoor unit away
from greasy dirt, vulcanization
gas exit.
7. Avoid installing it by the
roadside where there is a risk
of muddy water.
8. A fixed base where it is not subject to increased
operation noise.
9. Where there is not any blockage of the air outlet.
10. Avoid installing under direct sunlight, in an aisle
or sideway, or near heat sources and ventilation fans.
Keep away from flammable materials, thick oil fog,
and wet or uneven places.
If the height or pipe length is out of the scope of the
table, please consult the dealer.
Outdoor unit
Indoor unit
Pipe length is
15 meters Max.
b
e less than 5m
Height should
Model
5K~18K
5
15
Max. allowed pipe
length without additional
refrigerant (m)
Limit of
length (m)
pipe
21K 25K
~
28K~36K
5
15
5
15
5
20
Limit of Elevation
Difference H (m)
Required amount of
additional refrigerant
(g/m)
5
30
5
40
Indoor unit installation
1. Installing the Mounting Plate
Decide an installing location for the mounting plate
according to the indoor unit location and pipe
direction.
Keep the mounting plate horizontally with a
horizontal ruler or level.
Drill holes of 32mm in depth on the wall for fixing
the plate.
Insert the plastic plugs to the hole, fix the mounting
plate with tapping screws.
Inspect if the mounting plate is well fixed. Then
drill a hole for pipe.
Mounting plate
Tapping screw
Note: The shape of your mounting plate may be different
from the one above, but the installation method is similar.
Note: As the above figure shown, the six holes matched with
tapping screw on the mounting plate must be used to fix the
mounting plate, the others are prepared.