Страница 1: ...HI2022480HA INSTALLATION OPERATION MANUAL MODEL RAK AJ10PCASV RAC AJ10PCASV RAK AJ13PCASV RAC AJ13PCASV RAK AJ18PCASV RAC AJ18PCASV RAK AJ24PCASV RAC AJ24PCASV ...

Страница 2: ...ion will be further specified in following pages Signal transmit Dry indicator Fan only indicator Heating indicator Cooling indicator Higher fan speed High fan speed Medium fan speed Low fan speed Lower fan speed Display temperature Display set timer Display current time Auto fan speed Smart indicator ON OFF Used to adjust the room temperature and the timer also real time Sleep indicator 16 15 MUT...

Страница 3: ...le TEMP Airflow direction control Vertical airflow Horizontal airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit The direction of airflow can be also adjusted to your own requirement by pressing the SWING button of the remote controller Operation mode Direction of airflow COOLING DRY HEATING FAN ONLY horizontal downward Do not turn ...

Страница 4: ... it is convenient to install and well ventilated 2 Avoid installing it where flammable gas could leak 3 Keep the required distance apart from the wall The pipe length between indoor and outdoor unit should be not more than 5 meters in factory default status but it can go up to maximum 15 meters with additional refrigerant charge 6 Keep the outdoor unit away from greasy dirt vulcanization gas exit ...

Страница 5: ...t pipes power Cord and drain pipe should be thermal insulated and fixed onto the back of the unit with a pipe fixer A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Base Pipe fixer Pipe fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe Piping Connection If you don t hear the exhaust noise please contact with the ...

Страница 6: ... obtaining access to terminals all supply circuits must be disconnected Make sure that the color of the wires in the outdoor unit and terminal No are the same as those of the indoor unit the details please refer to the wiring diagram which is near the terminal inside the unit Cable Specifications Outdoor unit installation 1 Install Drain Port and Drain Hose for heat pump model only Drain hose prep...

Страница 7: ...fter using it for about 100 hours Protection Operating condition note The protective device maybe trip and stop the appliance in the cases listed below The temperature of some products is allowed beyond the range In specific situation please consult the merchant If the air conditioner runs in COOLING or DRY mode withdoor or window opened for a long time when relative humidity is above 80 dew may d...

Страница 8: ...The unit is shifting from heating mode to defrost The indicator will lights off within ten minutes and returns to heating mode The symbols may be different from these models but the functions are similar Example 8 1 2 3 4 Display introduction NO Display Introduction 7 9 11 12 13 14 1 5 8 6 3 4 10 2 Temperature indicator Display set temperature It shows FC after 200 hours of usage as reminder to cl...