Hitachi RAK-60NHA1 Скачать руководство пользователя страница 6

– 6 –

 

 

 

 

 

   

 

   

 

 

˚

CH

RESET

˚

CH

NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT

REMOTE CONTROLLER

  This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled 

electronically, the range of control may be shorter.

 

This unit can be 

fi

 xed on a wall using the 

fi

 xture provided. Before 

fi

 xing it, make sure the indoor unit can be controlled 

from the remote controller.

  Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission 

capability.

  After new batteries are inserted into the remote controller, the unit will initially require approximately 10 seconds to 

respond to commands and operate.

 

Signal emitting window/transmission sign

  Point this window toward the indoor unit when controlling it.
  The transmission sign blinks when a signal is sent.

 

Display

 

This indicates the room temperature selected, current time, timer status, function 
and intensity of circulation selected.

 

START/STOP button

  Press this button to start operation. Press it again to stop operation.

 

SLEEP button

  Use this button to set the sleep timer.

 

TEMPERATURE buttons

  Use these buttons to raise or lower the temperature setting. (Keep pressed, 

and the value will change more quickly.)

 

TIME button

  Use this button to set and check the time and date.

 

RESET buttons

 

FUNCTION selector

  Use this button to select the operating mode. Every time you press it, 

the mode will change from 

 (AUTO) to   (HEAT) to 

 (DEHUMIDIFY) to 

 (COOL) and to 

 (FAN) cyclically.

 

FAN SPEED selector

 

This determines the fan speed. Every time you press this button, the intensity 
of circulation will change from     (AUTO) to     (HI) to     (MED) to     (LOW) 
(This button allows selecting the optimal or preferred fan speed for each 
operation mode).

 

AUTO SWING button

  Controls the angle of the horizontal air de

fl

 ector.

 

TIMER control

  Use this button to set the timer.

 

OFF-TIMER button

   Select the turn OFF time.

 

ON-TIMER button

   Select the turn ON time.

 

RESERVE button

   Time setting reservation.

 

CANCEL button

   Cancel time reservation.

Precautions for Use

  Do not put the remote controller in the following places.

 

  Under direct sunlight.

 

  In the vicinity of a heater.

  Handle the remote controller carefully. Do not drop it on the 

fl

 oor, 

and protect it from water.

  Once the outdoor unit stops, it will not restart for about 3 minutes 

(unless you turn the power switch off and on or unplug the power 
cord and plug it in again).

 

This is to protect the device and does not indicate a failure.

  If you press the FUNCTION selector button during operation, the 

device may stop for about 3 minutes for protection.

(EN1) RAK-60-70NHA1   6

(EN1) RAK-60-70NHA1   6

3/27/14   6:24 PM

3/27/14   6:24 PM

Содержание RAK-60NHA1

Страница 1: ...ONDITIONER INDOOR UNIT MODEL RAK 60NHA1 RAK 70NHA1 INDOOR UNIT RAK 60NHA1 RAK 70NHA1 Instruction manual Page 1 24 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely ...

Страница 2: ...cation where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE Should abnormal situation arises like burning smell please stop operating the unit and turn off the circuit breaker Contact your agent Fault short circuit or fire may occur if you co...

Страница 3: ... water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intend...

Страница 4: ...te while the lamp lights To re start an indoor unit which was operated later stop the indoor unit which was operated first or later and reset the type of operation then perform operation again One unit Heating Other unit Cooling Dehumidifying Circulating fan Adjusting the Number of Indoor Units Decrease the number of indoor units to be operated especially when it is very hot or cold or when you wa...

Страница 5: ... about 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE OPERATION LAMP This lamp lights during operation The OPERATION LAMP flashes in the following cases during heating 1 During preheating For about 2 3 minutes after starting up 2 During defrosting Defrosting will be perform...

Страница 6: ...ep pressed and the value will change more quickly TIME button Use this button to set and check the time and date RESET buttons FUNCTION selector Use this button to select the operating mode Every time you press it the mode will change from AUTO to HEAT to DEHUMIDIFY to COOL and to FAN cyclically FAN SPEED selector This determines the fan speed Every time you press this button the intensity of circ...

Страница 7: ... necessary by maximum of 3 C Press the temperature button and the temperature setting will change by 1 C each time The preset temperature and the actual room temperature may vary somewhat depending on conditions The display does not indicate the preset temperature in the AUTO mode If you change the setting the indoor unit will produce a beep 1 RESET Press the FAN SPEED button AUTO and LOW is avail...

Страница 8: ... first and varies to MED or LOW automatically when the preset temperature has been reached HI Economical as the room will become warm quickly But you may feel a chill at the beginning MED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE buttons the display indicates the setting The temperature setting and the actual room temperature may vary somewhat depend...

Страница 9: ...he temperature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 20 26 C is recommended as the room temperature for dehumidifying Press the START STOP button Dehumidifying operation starts with a b...

Страница 10: ...ED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE button the display indicates the setting The temperature setting and the actual room temperature may vary some how depending on conditions Press the START STOP button Cooling operation starts with a beep Press the button again to stop operation The cooling function does not start if the temperature setting...

Страница 11: ... and setting temperature is large fan starts to run at HI speed After room temperature reaches the preset temperature the cooling operation which changes the fan speed and room temperature to obtain optimum conditions for natural healthful cooling will be performed For the cooling operation FAN OPERATION You can use the device simply as an air circulator Use this function to dry the interior of th...

Страница 12: ...lay NOTE You can set only one of the OFF timer ON timer and ON OFF timer ON Ti mer Ti me Day Month The device will turn on at the designated times TIME DAY MONTH current time day month OFF TIMER ON TIMER RESERVE CANCEL M D M D AM STOP Start AM Start Stop PM Start Stop PM AM PM RESET The device will turn on off and off on at the designated times The switching occurs first at the preset time that co...

Страница 13: ...of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting instead of flashing and the RESERVED sign lights A beep occurs and the TIMER lamp lights on the indoor unit 3 Point the signal window of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting instead of flashing and the RESERVED sign lights A beep ...

Страница 14: ... 2 Press the SLEEP button and set the sleep timer The device will be turned off by the sleep timer and turned on by on timer How to Cancel Reservation Point the signal window of the remote controller toward the indoor unit and press the CANCEL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit For heating In this case the device will turn off in 2 hours a...

Страница 15: ...al air deflector within the adjusting range shown on the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes When cooling dehumidifying When heating CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop RESET Adjustment...

Страница 16: ...he old batteries 2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months CAUTION ush and ull to the direction of arrow ...

Страница 17: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and o...

Страница 18: ...be used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Caution To avoid noise interf...

Страница 19: ... out only by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air cleansing and deodorizing filter as it may cause damage to the structure NOTE In case of removing the air cleansing and deodorizing filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when th...

Страница 20: ...h soft bristle brush Allow filters to dry in shade 3 Re insert the air cleansing and deodorizing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filter may shrink When washing i...

Страница 21: ...d the front panel with both hands to detach and attach it CAUTION Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel Arm When the front panel is fully opened with both hands push the right a...

Страница 22: ...QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY CONTACT YOUR SALES AGENT OR SERVICE SHOP Is the earth line disconnected or broken Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable Is the plug of power line firmly plugged into the socket Please ensure no loose contact between them Air Blow Cleaning and maintenance must be carried out only by q...

Страница 23: ... odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit production number date of installation Please also inform him regarding the faul...

Страница 24: ... 24 MEMO ...