10-3
TIMER
LAMP
BLINKING
LD301
BLINKING
CODE
MEANING
O
U
T
D
O
O
R
4 times
6 times
OH thermistor temperature rise
4 times
7 times
Abnormal outdoor thermistor
4 times
9 times
Communication error
4 times
10 times
Abnormal power source
4 times
11 times
Fan stop for strong wind
4 times
12 times
Fan motor fault
4 times
13 times
EEPROM reading error
4 times
14 times
Active converter defective
4 times
15 times
Abnormal PWB circuit