5. Connection of the connecting cord

(1) Remove the cover of the electric box.
(2) Connect the connecting cords.
(3) Assemble the cover of electric box.

3. Fixing the indoor unit

438

440

155

55

ø9 rear fixing

hole for

anchor bolt or

screw of

accessory.

Fixing on the wall

Case

Fixing the base of indoor unit

Fix the base of indoor unit on the floor with 4.1 

×

 32mm screws. (Right and left)

2. Push plug into the holes.

1. Drill holes on floor.

(The plug can be secured diagonally with a screw as shown above.)

 WARNING

Be sure to attach screw   to prevent
the indoor unit from overturn.

3

When  fixing  the  indoor  unit  above
the ground, be sure to fix an L-angle
at the bottom to support it.

  Screw (4.1x32)

Indoor unit

Plug (Procure locally)

If outlet is covered with the lattice door, room temperature may not be controlled
properly. Therefore, air outlet must be open as much as possible.
If air deflector of air outlet is adjusted too much upward, room temperature may
not be controlled properly due to the heat inside the lattice door. Therefore, the
deflector must be adjusted to nearly horizontal angle.
If signal receiver is covered with the lattice door, signal receiving distance or
range (angle) becomes smaller. Therefore, signal receiver must not be covered
with the lattice door.
Only the vertical lattice door may be used. Be sure to use a lattice door with an
open area ratio of 75% or more. If another lattice door or one with an open area
ratio of less than 75% is used, maximum performance may not be obtained.
With a built-in installation, it may take more time to reach the set temperature
after the unit is switched on.

 WARNING

Leave some space in the connecting cord for
maintenance purpose and be sure to secure it
with the cord band.
Secure  the  connecting  cord
along  the  coated  part  of  the
wire using the cord band. Do
not exert pressure on the wire
as this may cause overheating
or fire.

Please ensure the smooth flow of condensed water of the Indoor unit during installation.
(Carelessness may result in water leakage.)

 CAUTION

 WARNING

Be sure that the hose is not loosely
connected or bent.

6. Checking of drawing drain hose

(1) Connect the separate drain hose to the drain hose that is attached to the indoor unit.
(2) For keeping the smooth flowing of condensed water the drain hose should be inclined as shown in figure below.

7. Installation of remote controller

The remote controller can be placed in its holder which is
fixed on wall or beam.
To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be fixed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the fluorescent light. Therefore,
during the installation of the remote control holder, please
switch on the light, even during day time, to determine the
mounting location of the holder.

8. Final stage of installation
8.1

Insulation and maintenance of pipe connection

The connected terminals should be completed sealed with heat insulator and then tied
up with rubber strap.
Please tie the pipe and power line together with vinyl tape as shown in the figure showing
the installation of Indoor and Outdoor units. Then fix their position with holders.
To enhance the heat insulation and to prevent water condensation, please cover the
outdoor part of the drain hose and pipe with insulation pipe.
Completely seal any gap with putty.

8.2

Operation test

Please ensure that the air conditioner is in normal operating condition during the operation test.
Explain to your customer the proper operation procedures as described in the user’s manual.
If the indoor unit does not operate, check to see that the connections are correct.

Sleeve of

protection pipe

Putty

Putty

OUTSIDE     INSIDE

Horizontal air deflector (Air intake)

Signal receiver

Above

100mm

Above 200mm

Above 150mm

Lattice door

Screw

Screw

 Screw (4.1x32)

Horizontal air deflector (Air outlet)

3-3 Built-in Installation

Direct Mounting On The Wall

Procedures of Installation and Precautions

Procedures to fix the hanger and indoor unit.
1.Drill holes on wall.

(As shown below)

2.Push plug into the holes.

(As shown below)

3.Fix the hanger on wall with 4.1 X

32 and 4.0 X 34 screw.

(As shown in figure below)

Wall

m

m8.

4

ø

32mm

Wall

Plug

Hanger

 Screw

    (4.1x32)

4. Installation of refrigerating pipes and air removal
4.1

Preparation of pipe

Use a pipe cutter to cut the copper pipe.

fore flaring, please put on the flare nut.

Trimming tool

Copper

 CAUTION

Jagged edge will cause leakage.
Point the side to be trimmed downwards during trimming to
prevent copper chips from entering the pipe.

Outer Diameter (ø)

A (mm) Rigid Flaring Tool

For R410A tool

For R22 tool

6.35 (1/4")

0 – 0.5

1.0

9.52 (3/8")

0 – 0.5

1.0

12.7 (1/2")

0 – 0.5

1.0

4.2

Pipe connection

Please be careful when bending the copper pipe.
Screw in manually while adjusting the center. After that,
use a torque wrench to tighten the connection.

In case of removing flare nut of a indoor unit, first remove a nut of small diameter side, or a seal cap of

big diameter side will fly out. Free from water into the piping when working.

 CAUTION

 Outer diameter

Torque N·m

of pipe (ø)

(kgf·cm)

Small diameter side

6.35 (1/4")

13.7 – 18.6 (140 – 190)

Large diameter side

9.52 (3/8")

34.3 – 44.1 (350 – 450)

12.7 (1/2")

44.1 – 53.9 (450 – 550)

Valve head

Small diameter side

6.35 (1/4")

19.6 – 24.5 (200 – 250)

Large diameter side

9.52 (3/8")

19.6 – 24.5 (200 – 250)

cap

12.7 (1/2")

29.4 – 34.3 (300 – 350)

)

0

6

1

 

 

5

2

1

7

.

5

1

 

 

3

.

2

1

p

a

c

 

e

r

o

c

 

e

v

l

a

V

Trial run should be conducted on one unit at a time to check for incorrect wiring of connecting cord.

 CAUTION

 Screw

    (4.1x32)

Fixing on the hanger

3.2 Wall Installation

3.1 Floor Installation

30mm

Air conditioner

External dimension of

indoor unit

20mm

750mm

m

m0

5

m

m0

74

55mm

Drain Hose

20mm

CAUTION

The  draining  of  the  water  container

inside  the  Indoor  unit  can  be  done

from  the  left. Therefore  the  hanger

must be fixed horizontally or slightly

tilted towards the side of drain hose.

Otherwise,  condensed  water  may

overflow the water container.

A

Die

Please use exclusive tool.

Copper pipe

Die

Connection of the connecting cord

Securely screw in the connecting cord so that it will not get loose or
disconnect.
Tightening torque reference value: 1.2 to 1.6 N·m (12 to 16 kgf·cm)
Excessive  tightening  may  damage  the  interior  of  the  cord  requiring
replacement.

 THIS APPLIANCE MUST BE

  EARTHED.

WARNING

Bending

upwards

Bad

Condensed

water pond

Bad

Bad

Condensed

water pond

Bad

Ditch

 

 

 

 

 

 

   

 

 

 

 

 

 

   

   

 

Remote Controller 

Holder

Screw (2 pieces)

 

Remote Controller

Using the claws at the top of front cover to remove and install front cover to the cabinet. Too much force on the
claws may cause breakage when removing or installing the front cover. Please follow the below procedures for
removal and installation of front cover.

 CAUTION

Removal and installation of front cover

 Push the latch at both sides to open the front panel. Pull out the filter and remove 3 screws.

 Lift up the front panel and latch the claws 

firmly at the lower part of rear of the front 
panel. 
Then remove 3 screws.

 Take off 2 screw caps at the lower part of 

the horizontal air deflector and remove 2 
screws.  Then  leave  the  upper  louver  in 
open position.

  Set the upper louver in open position.

Insert the front cover fixing claws  
(4 places) to the insertion groove of the 
cabinet and put the upper louver through 
to the front cover frame.

 

Put the horizontal air deflector to the 

lower part of front cover frame and insert 
to the cabinet. 
After fixed the front cover, fix back all the 
screws in order.

 Hold both sides of the lower part of front 

cover  and  pull  down  towards  an  oblique 
direction.

2. Install the front cover

1. Remove the front cover

Latch

Latch

Screw

Screw

Screw

Screw Cap

Upper Louver

Upper Louver

Horizontal
Air Deflector

Horizontal
Air Deflector

Lower Flame

Front Panel

Front Panel

Front Cover

Front Cover

Front Cover Fixing Claws (4 places)

Front Cover 
Fixing Claws 
(4 places)

Claw

Cabinet

Cabinet

Cabinet

How to connect the optional parts 

(H-LINK RAC Adapter, Dry contact, Wired Remote Controller)

For cable connection to control P.W.B., you need to remove front cover and electrical box cover.

Each connecting location is as below.

 Dry contact: CN6
 H-LINK RAC Adapter: CN7
 Wired Remote Controller: CN20

Please check and confirm manuals attached to each optional parts for more connection details.
You can refer to this installation manual how to remove and re-attach the front cover.
Please be careful not to damage lead wires by edge of plate when connecting the optional parts.

Flare nut

Wrench

Torque wrench

Please use gas leakage detector to check
if leakage occurs at connection of flare nut
as shown on the right.

If  gas  leakage
occurs,  further
tighten 

the

connection to stop
leakage. (Use the
detector  provided
for R410A.)

Gas leakage inspection

ss

el r

m

m4

81

Please remove 3 screws and clip

which fix the stand and cabinet.

(As shown in the figure below)

Please remove the screws which fix

the cabinet and hanger.

Please use hidden beams in the wall

to hold the hanger.

Hole for pipe

Hanger

Mark

Level

Line

Weight

Screw for Hanger

Please use more
than 6 screws

 Screw

    (4.1x32)

1. Drill holes on wall.

(As shown below)

2. Push plug into the holes.

(As shown below)

Wall

m

m8.

4

ø

32mm

Wall

Cabinet

Screw

(4.1x32)

 Screw (4.1x32)

 Screw

    (4.1x32)

 Screw

    (4.1x32)

 Screw

    (4.1x32)

4.Fix the indoor unit on the

wall with 4.1x32 screw.

Plug

 Screw

    (4.0x34)

 Screw

    (4.0x34)

 3

 3

 3

 9

 3

 3

 3

 9

 3

 1

 

 3

 3

 2

 1

  2

 3

 3

  4

 1

2

 3

5

4

3

2

1

3

< S904 :   >

B

The remote controller

 

must be slide in the remote

 

controller holder, in the 
direction as shown in the 

lower end of the remote

 

figure, until it hooks at the

controller holder.

RAF-25RXB_EN

Detail of cutting the connecting cord

35mm

10mm

10mm

70mm

1
2
3

Connecting cord

Green + Yellow

(ground)

Connecting cord

1

2

3

Cord band

Earth

Connecting cord

CN20

CN7

CN6

Отзывы: