Gas Leakage Inspection
Please use gas leakage detector to check if leakage occurs
at the connection of Flare nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop
leakage.
<
IA1104: B
>
Preparation of Pipe
1
●
Use a pipe cutter to cut the copper pipe.
●
Jagged edge will cause leakage.
●
Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
●
Before
fl
aring, please put on the
fl
are nut.
Pipe Connection
2
INST
ALLA
TION OF REFRIGERA
TING PIPES
AND
AIR REMOV
AL
CAUTION
!
WARNING
●
If you cannot attach the side plate due to the connecting
cord, press the connecting cord in direction to the front
panel to
fi
x it.
●
Be sure that the hooks of the side plate is
fi
xed in certainly.
Otherwise water leakage may occur and this causes short
circuit or faults.
Checking for the electric source and the
voltage range
●
Before installation, the power source must be checked and necessary wiring work
must be completed. To make the wiring capacity proper, use the wire gauges list
below for the lead-in from a pole transformer and for the wiring from a switch
board of fuse box to the outlet in consideration of the locked rotor current.
●
Investigate the power supply capacity and other electrical
conditions at the installation location.
Depending on the model of room air conditioner to be installed,
request the customer to make arrangements for the necessary
electrical work etc.
The electrical work includes the wiring work up the outlet.
In localities where electrical conditions are poor, use of a
voltage regulator is recommended.
●
Install outlet for the room air conditioner within the reaching
range of the line cord.
●
THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring
Wiring Of The Outdoor Unit
●
Please remove the side plate for wire connection.
!
WARNING
!
CONNECTION OF POWER CORD
WARNING
!
Power supply shall be connected at the rated voltage, otherwise the unit will be
broken or could not reach the speci
fi
ed capacity.
Detail of cutting the connecting cord
To remove the connecting wires for
the indoor unit, please remove the
low cover panel in front of the unit.
Earth terminal
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove front panel and
electrical cover.
Method to remove front panel
●
Please refer to Instruction Manual – “Removing the Front Panel” under “Cleaning
of Front Panel”.
●
The naked part of the wire core should be 10 mm and
fi
xed to the terminal tightly. Then try
to pull the individual wire to check if the contact is tight. Improper insertion may burn the
terminal.
●
Be sure to use only power cables approved from the authorities in your country. For example
in Germany: Cable type: NYM 3x1.5mm
2
, (fuse = 16A time delay)
●
Please refer to the following for wire connection to the terminals of the units. The cabling
must meet the standards of electrical installation.
●
There is a AC voltage of 220~230V between the L and N terminals. Therefore, before
servicing, be sure to remove the plug from the AC outlet or switch off the main switch.
IMPORTANT
15A time delay fuse
Fuse Capacity
Removal Of Air From The Pipe And Gas Leakage Inspection
3
Procedures of using Vacuum Pump for Air Removal
AIR REMOV
AL
When the meter reaches - 101kPa (-76cmHg)
during pumping, fully tighten the shuttle.
Lo
Hi
Meter showing pressure
Closed
Manifold valve
Vacuum
pump
Valve
Charge hose
Valve
When pumping starts, slightly loosen the
fl
are nut to check of air sucked in. Then
tighten the
fl
are nut.
As shown in right
fi
gure, remove the cap of
valve core. Then, connect the charge hose.
Remove the cap of valve head. Connect the
vacuum pump adapter to the vacuum pump
and connect the charge hose to the adapter.
Fully tighten the “Hi” knob of the manifold
valve and completely unscrew the “Lo” knob.
Run the vacuum pump for about 10~15
minutes, then completely tighten the “Lo” knob
and switch off the vacuum pump.
2
Completely unscrew the spindle of the
service valve (at 2 places) in anti-clockwise
direction to allow the
fl
ow of refrigerant (using
Hexagonal Wrench key).
Re-cap the service valve and tighten using
wrench. Check the cap’s periphery if there is
any gas leakage. The task is then completed.
Remove the charge hose and tighten the cap
of valve core. Check the cap’s periphery if
there is any gas leakage.
4
5
1
3
OUTDOOR UNIT
●
Please mount the Outdoor unit on stable ground to prevent
vibration and increase of noise level.
●
Decide the location for piping after sorting out the different
types of pipe available.
●
When removing side cover, please pull the handle after undoing
the hook by pulling it downward.
Please face this side (suction side)
of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Please make sure to remove all spacers inside the unit.
●
Open the Top, Back, Side cover and Cabinet of the unit.
●
Pull out the spacers inside.
(Spacers are only for transportation purpose).
If not remove, vibration and noise will occur.
!
Top cover
CAUTION
Back cover
Side cover
CAUTION
!
In case of removing
fl
are nut of an Indoor unit,
fi
rst remove the nut
of small diameter side, or a seal cap of bigger diameter side will
burst out. Prevent water from entering into the piping when working.
B
A
!
CAUTION
Note:
●
Outdoor supply cords shall not be lighter than polychloroprene sheathed
fl
exible cord, 60245 IEC 57.
Pull downward
Vacuum
pump
adapter
Method to remove electrical cover
●
Remove the screw and electrical cover.
●
Insert the connecting cord (A, B) from the back of unit.
●
Fixed the wire to terminal wires
fi
rmly as shown in
fi
gure.
Electrical cover
Connecting cord
Screw
Connect the earth cord
After remove the screw
and band, put the
connecting cords and
fi
x the band with screw.
FINAL
ST
AGE OF INST
ALLA
TION
Insulation And Maintenance Of Pipe Connection
1
●
The connected terminals should be completed sealed with heat
insulator and then tied up with rubber strap.
●
Please tie the pipe and power line together with vinyl tape as
shown in the
fi
gure showing the installation of indoor and outdoor
units. Then
fi
x their position with holders.
●
To enhance the heat insulation and to prevent water condensation,
please cover the outdoor part of the drain hose and pipe with
insulation pipe.
●
Completely seal any gap with putty.
Installation Of Remote Controller
2
●
The remote controller can be placed in its holder which is
fi
xed
on wall or beam.
●
To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be
fi
xed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the
fl
orescent light. Therefore, during
the installation of the remote control holder, please switch on the
light, even during day time, to determine the mounting location
of the holder.
The controller should
be insert from top into
bottom side of the
holder as shown in
fi
gure beside.
●
How to check pipe bending.
– Compare bended pipe with the picture below.
– If bended pipe is not good enough, cut bended
area and bend it again.
a all areas are smooth, no notching area
b no scratch or mark inside
c all have the same length
d phase of bending is too long
e slanting
f there are scratches around bending area
g crack
h different
length
i sample of bending pipe cannot be used
Proper Pump Down Method
1
Operate air conditioner
at cooling mode for
10~15 minutes
2
After 10~15 minutes of
pre operation, close 2s
valve. After 3 minutes,
close 4s valve.
3
Take out air conditioner unit.
4
Install New Refrigerant
air conditioner
Most Important Process
Purpose: To make the
oil & refrigerant mix
together. They are in
separated condition when
air conditioner is
stopped.
Mixed
refrigerant
& oil will be
collected into
outdoor unit.
It is advisable to
fl
ush
the piping with R-22 to
avoid any contamination
remain before new
installation.
Outer
Diameter (ø)
6.35 (1/4")
12.7 (1/2")
Imperial
fl
aring tool
0.8 ~ 1.5
1.0 ~ 2.0
Rigid
fl
aring tool
0 ~ 0.5
0 ~ 1.0
A (mm)
Outer
diameter
of pipe
6.35 (1/4")
12.7 (1/2")
Valve head cap
Valve core cap
Torque N.m
(kgf
●
cm)
13.7 ~ 18.6 (140 ~ 190)
44.1 ~ 53.8 (450 ~ 550)
19.6 ~ 24.5 (200 ~ 250)
12.3 ~ 15.7 (125 ~ 160)
Small diameter
side
Big diameter
side
Power Source And Operation Test
3
Power Source
CAUTION
!
●
Please use a new socket. Accident may occur due
to the use of old socket because of poor contact.
●
Please plug in and then remove the plug for 2 – 3
times. This is to ensure that the plug is completely
plugged into the socket.
●
Keep additional length for the power cord and do
not render the plug under external force as this may
cause poor contact.
●
Do not
fi
x the power cord with U-shape nail.
Operation Test
●
Please ensure that the air conditioner is in normal
operating condition during the operation test.
●
Explain to your customer the proper operation procedures
as described in the user’s manual.