HEATING OPERATION
Defrosting will be performed about once an hour when frost forms on the heat exchange of the
outdoor unit
, it takes about 5-10 minutes of each cycle.
During defrosting operation, the operation lamp blinks in cycle of 2 seconds on and 1 second off.
The maximum time for defrosting is 20 minutes.
(If the piping length used is longer than usual, frost will likely to form.)
1
2
Defrosting
■
Press the MODE selector button so that the display indicates
(HEAT).
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO)
(HIGH)
(MED)
(SILENT)
(LOW)
Set the desired room temperature with the TEMPERATURE buttons
(the display indicates the setting).
The temperature setting and the actual room temperature may
vary depending on conditions.
Temperature range can be set between 16°C and 32°C.
Press the
(ON/OFF) button. Heating operation starts with
a beep. Press the button again to stop operation.
■
As the settings are stored in the memory of the remote
control
, you
only have to press the
(ON/OFF) button next time.
■
During AUTO fan, the fan speed automatically changes as below:
●
When the difference between room temperature and setting temperature
is large, fan starts to run at HI speed.
●
After room temperature reaches the preset temperature, fan speed
will be changed to lower speed to obtain optimum room temperature
condition for natural healthy
airflow
.
1
2
3
START
STOP
●
Use the
unit
for heating when the outdoor temperature is under 27°C.
When it is too warm (over 27°C), the heating function may not work in order to protect the
unit
.
●
In order to keep reliability of the
unit
, please use this device above –
2
°C of the outdoor
temperature.
Sleep
Right/Left
F.Wash
Silent
Sleep
Right/Left
F.Wash
Silent
- 9 -
ENGLISH