Hitachi RAC-70WPA Скачать руководство пользователя страница 2

–  2  –

SAFETY  PRECAUTION

 

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

 

Pay  special  attention  to  signs  of  “

!

Warning

”  and  “

!

Caution

”.  The  “Warning”  section  contains  matters  which,  if  not 

observed  strictly,  may  cause  death  or  serious  injury. The  “Caution”  section  contains  matters  which  may  result  in  serious 
consequences if not observed properly. Please observe all instructions strictly to ensure safety.

 

The sign indicate the following meanings.

 

Make sure to connect earth line.

 

The sign in the 

Þ

 gure indicates prohibition.

  Indicates the instructions that must be followed.

 

Please keep this manual after reading.

PRECAUTIONS  DURING  OPERATION

 

Avoid an extended period of direct air 

ß

 ow for your health.

W

A
R
N

I

N
G

!

 

Do not insert a 

Þ

 nger, a rod or other objects into the air outlet or inlet. As the fan is rotating 

at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn 
the breaker OFF.

 

Do not use any conductor as fuse wire, this could cause fatal accident.

PRECAUTIONS  DURING  SHIFTING  OR  MAINTENANCE

  Should abnormal situation arises (like burning smell), please stop operating the unit and turn 

off the circuit breaker. Contact your agent. Fault, short circuit or 

Þ

 re may occur if you continue 

to operate the unit under abnormal situation.

  

Please contact your agent for maintenance. Improper self maintenance may cause electric 
shock and 

Þ

 re.

  

Please contact your agent if you need to remove and reinstall the unit. Electric shock or 

Þ

 re 

may occur if you remove and reinstall the unit yourself improperly.

  

If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the  special  cord  obtainable  at  
authorized service/parts centers.

W

A
R
N

I

N
G

!

   

During  thunder  storm,  disconnect  and  turn  off  the  circuit  breaker.

WARNING

PRECAUTIONS  DURING  INSTALLATION

  Do  not  reconstruct  the  unit.

 

Water leakage, fault, short circuit or 

Þ

 re may occur if you reconstruct the unit by yourself.

  Please ask your sales agent or quali

Þ

 ed technician for the installation of your unit. Water 

leakage,  short  circuit  or 

Þ

 re  may  occur  if  you  install  the  unit  by  yourself.

  Please  use  earth  line.

 

Do  not  place  the  earth  line  near  water  or  gas  pipes,  lightning-conductor,  or  the  earth 
line  of  telephone.  Improper  installation  of  earth  line  may  cause  electric  shock.

  Be sure to use the speci

Þ

 ed piping set for R410A. Otherwise, this may result in broken 

copper  pipes  or  faults.

  A circuit breaker should be installed depending on the mounting site of the unit. Without 

a  circuit  breaker,  the  danger  of  electric  shock  exists.

  Do  not  install  near  location  where  there  is 

ß

 ammable  gas.  The  outdoor  unit  may  catch 

Þ

 re  if 

ß

 ammable  gas  leaks  around  it.

  Please  ensure  smooth 

ß

 ow  of  water  when  installing  the  drain  hose.

  Do  not  install  the  indoor  unit  in  a  machine  shop  or  kitchen  where  vapor  from  oil  or  its 

mist 

ß

 ows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing 

the  indoor  unit  performance  and  may  deform  and  in  the  worst  case,  break  the  plastic 
parts  of  the  indoor  unit.

CAUTION

!

!

 

Spray  cans  and  other  combustibles  should  not  be  located  within  a  meter  of  the  air  outlets 
of  both  indoor  and  outdoor  units.

  As  a  spray  can’s  internal  pressure  can  be  increased  by  hot  air,  a  rupture  may  result.

Содержание RAC-70WPA

Страница 1: ...INDOOR UNIT OUTDOOR UNIT RAC 70WPA MODEL SPLIT TYPE HITACHI RAK 70PPA RAC 70WPA OUTDOOR UNIT INDOOR UNIT RAK 70PPA ...

Страница 2: ...cur if you remove and reinstall the unit yourself improperly If the supply cord is damaged it must be replaced by the special cord obtainable at authorized service parts centers W A R N I N G During thunder storm disconnect and turn off the circuit breaker WARNING PRECAUTIONS DURING INSTALLATION Do not reconstruct the unit Water leakage fault short circuit or Þre may occur if you reconstruct the u...

Страница 3: ... water will condense on the air deßector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intende...

Страница 4: ...HT mm 333 800 DEPTH mm 245 298 MODEL NAME AND DIMENSIONS OUTDOOR UNIT DRAIN PIPE Condensed water drain to outside CONNECTING CORD AIR INLET BACK LEFT SIDE AIR OUTLET Air purifying Þlters are not washable It is recommended to use vacuum to clean it It can be use for 1 year time Type number for this air purifying Þlter is SPX NTW2 Please use this number for ordering when you want to renew it Air pur...

Страница 5: ... each time FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean the Þlter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work Use non conductor stick example toothpick By pressing the tempor...

Страница 6: ...20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 Note The recommended temperature range for safety testing should be as below Cooling Heating CIRCUIT BREAKER When you do not use the room air conditioner set the circuit breaker to OFF ...

Страница 7: ... ON timer operation mode together with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty pre Þlter will reduce the air volume and the cooling efÞciency To prevent from wasting electric energy please clean the Þlter every 2 weeks Please pay attention to the room temperature and air ßow direction when operating the un...

Страница 8: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 12W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferen...

Страница 9: ... After attaching the Pre Þlters push the front panel at three arrow portions as shown in Þgure and close it Cleaning and maintenance must be carried out when Þlter lamp lights Before cleaning stop operation and switch off the power supply Do not bend the air purifying Þlter as it may cause damage to the structure Please do not smell direct from source of Þlter In case of removing the air purifying...

Страница 10: ...r purifying Þlters from the air purifying Þlter frame Vacuum dust from the Pre Þlter and air purifying Þlter using vacuum cleaner If there is too much dust rinse under running tap water and gently brush it with soft bristle brush Allow Þlters to dry in shade Re insert the air purifying Þlter to the Þlter frame Set the Pre Þlter with FRONT mark facing front and slot them into the original state Aft...

Страница 11: ... clean water When front panel is not removed wipe it with a soft dry cloth Wipe the remote controller thoroughly with a soft dry cloth Wipe the water thoroughly If water remains at indicators or signal receiver of indoor unit it causes trouble Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it When the front panel is fully opened with both ha...

Страница 12: ...e Is the plug of power line Þrmly plugged into the socket Please ensure no loose contact between them Cleaning and maintenance must be carried out only by qualiÞed service personnel Before cleaning stop operation and switch off the power supply CAUTION 3 MAINTENANCE AT BEGINNING OF LONG OFF PERIOD Run the unit by setting the operation mode to COOL the temperature to 32 C and the fan speed to HI fo...

Страница 13: ...cause the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the pre Þlter and the evaporator regularly must be cleaned to reduce the odor Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit production number date of installation Please also inform him re...

Страница 14: ... 14 MEMO ...

Отзывы: