MAINTENANCE

Cleaning and maintenance must be carried out only by quali

Þ

 ed service personal.  

Before cleaning, stop operation and switch off the power supply.

CAUTION

CAUTION

!

!

1

2

3

1.      PRE-FILTER

Clean  the  Pre-

Þ

 lter,  as  it  removes  dust  inside  the  room.  In  case  the  Pre-

Þ

 lter  is  full  of  dust,  the  air 

ß

 ow 

will  decrease  and  the  cooling  capacity  will  be  reduced.  Further,  noise  may  occur.  Be  sure  to  clean  the 
Pre-

Þ

 lter  following  the  procedure  below.

Open  the  front  panel  and  remove  the  Pre-

Þ

 lter

  Gently  lift  and  remove  the  air  purifying 

Þ

 lters 

from  the  air  purifying 

Þ

 lter  frame.

Vacuum  dust  from  the  Pre-

Þ

 lter  and  air  purifying 

Þ

 lter  using  vacuum  cleaner.  If  there  is  too  much 

dust,  rinse  under  running  tap  water  and  gently 
brush  it  with  soft  bristle  brush. Allow 

Þ

 lters  to  dry 

in  shade.

  Re-insert the air purifying 

Þ

 lter to the 

Þ

 lter frame. 

Set the Pre-

Þ

 lter with “FRONT” mark facing front, 

and  slot  them  into  the  original  state.

  After  attaching  the  Pre-

Þ

 lters,  push  the  front 

panel  at  three  arrow  portions  as  shown  in    

Þ

 gure  and  close  it.

 

Do  not  wash  with  hot  water  at  more  than  40°C.  The  pre-

Þ

 lter  may  shrink.

  When  washing  it,  shake  off  moisture  completely  and  dry  it  in  the  shade;  do  not  expose  it  directly  to 

the  sun.  The  pre-

Þ

 lter  may  shrink.

Содержание RAC-60WPA

Страница 1: ...SPLIT TYPE AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT RAK 60PPA OUTDOOR UNIT INDOOR UNIT MODEL RAC 60WPA RAK 60PPA RAC 60WPA ...

Страница 2: ...cur if you remove and reinstall the unit yourself improperly If the supply cord is damaged it must be replaced by the special cord obtainable at authorized service parts centers W A R N I N G During thunder storm disconnect and turn off the circuit breaker WARNING PRECAUTIONS DURING INSTALLATION Do not reconstruct the unit Water leakage fault short circuit or Þre may occur if you reconstruct the u...

Страница 3: ... water will condense on the air deßector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intende...

Страница 4: ... indoor unit So as to operate the whole unit Refer Remote control manual MODEL NAME AND DIMENSIONS OUTDOOR UNIT DRAIN PIPE Condensed water drain to outside CONNECTING CORD AIR INLET BACK LEFT SIDE AIR OUTLET Air purifying Þlters are not washable It is recommended to use vacuum to clean it It can be use for 1 year time Type number for this air purifying Þlter is SPX NTW1 Please use this number for ...

Страница 5: ... about 200 hours the FILTER lamp lights to indicate that it is time to clean the Þlter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work Use non conductor stick example toothpick By pressing the temporary switch the operation is done in automatic mode When the opera...

Страница 6: ...g should be as below Cooling Heating Minimum Maximum Minimum Maximum Indoor Dry bulb C 21 32 20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 CIRCUIT BREAKER When you do not use the room air conditioner set the circuit breaker to OFF ...

Страница 7: ...ing This will enable you to enjoy a comfortable room temperature Please use the timer effectively Please pay attention to the room temperature and air ßow direction when operating the unit for baby children and old folks who have difÞculty in movement Caution Do not close the room for a long period of time Occasionally open the door and windows to allow the entrance of fresh air THE IDEAL WAYS OF ...

Страница 8: ... used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 12W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferenc...

Страница 9: ...nce must be carried out when Þlter lamp lights Before cleaning stop operation and switch off the power supply Do not bend the air purifying Þlter as it may cause damage to the structure Please do not smell direct from source of Þlter In case of removing the air purifying Þlters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when th...

Страница 10: ...he air purifying Þlters from the air purifying Þlter frame Vacuum dust from the Pre Þlter and air purifying Þlter using vacuum cleaner If there is too much dust rinse under running tap water and gently brush it with soft bristle brush Allow Þlters to dry in shade Re insert the air purifying Þlter to the Þlter frame Set the Pre Þlter with FRONT mark facing front and slot them into the original stat...

Страница 11: ...re to hold the front panel with both hands to detach and attach it CAUTION Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel When the front panel is fully opened with both hands push the ri...

Страница 12: ...e Is the plug of power line Þrmly plugged into the socket Please ensure no loose contact between them Cleaning and maintenance must be carried out only by qualiÞed service personnel Before cleaning stop operation and switch off the power supply CAUTION 3 MAINTENANCE AT BEGINNING OF LONG OFF PERIOD Air Blow ConÞrm Run the unit by setting the operation mode to COOL the temperature to 32 C and the fa...

Страница 13: ...will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the pre Þlter and the evaporator regularly must be cleaned to reduce the odor Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit product...

Страница 14: ... 14 MEMO ...

Отзывы: