Hitachi RAC-50YHA1 Скачать руководство пользователя страница 12

– 12 –

HOW TO SET THE TIMER

ON/OFF-Timer

The device will turn on (off) and off
(on) at the designated times.

The switching occurs first at the
preset time that comes earlier.

The arrow mark appearing on the
display indicates the sequence of
switching operations.

1

 

Press the        (ON-OFF)

button so that the     (OFF)
mark blinks.

OFF-Timer

You can set the device to turn off
at the present time.

After you change the
batteries;

How to Cancel Reservation

Point the signal window of the remote controller toward the indoor unit, and press the    (CANCEL)
button.
The    (RESERVED) sign goes out with a beep and the    (TIMER) lamp turns off on the indoor unit.

1

 

Set the current month and

day with the TIMER control
button.

1

 

Press the        (OFF-TIMER)

button. The      (OFF) mark blinks
on the display.

1

 

Press the       (ON-TIMER)

button the     (ON) mark blinks
on the display.

2

 

Set the turn-off time

with the TIMER control
button.
Press the    (RESERVE)
button.

3

 

Press the    (ON-

TIMER) button so that the
    (OFF) mark lights and
the   (ON) mark blinks.

 NOTE

You can set only one of the OFF-timer,
ON-timer and ON/OFF-timer.

ON-Timer

Time, Day, Month

The device will turn on
at the designated times.

TIME, DAY,
MONTH
(current time,
day, month)

OFF TIMER

ON TIMER

RESERVE

CANCEL

M

D

M

D

AM

STOP

Start

AM

Start

Stop

PM

Start

Stop

PM

AM

PM

RESET

Содержание RAC-50YHA1

Страница 1: ...DOOR UNIT OUTDOOR UNIT MODEL RAS 50YHA1 RAC 50YHA1 INDOOR UNIT RAC 50YHA1 Instruction manual Page 1 24 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely RAS 50YHA1 OUTDOOR UNIT ...

Страница 2: ... outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION Make sure to connect earth line Indicates the instructions that must be followed The sign in the figure indicates prohibition PRECAUTIONS DURING OPERATION Avoid an extended period of direct air flow for your health W A R N I N G Do not insert a finger a rod or oth...

Страница 3: ... water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intend...

Страница 4: ...r Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 Drain pipe Condensed water drain to outside Connecting cord and insulation pipe for piping Air inlet Back and Left side Air outlet WIDTH mm 1030 850 MODEL RAS 50YHA1 RAC 50YHA1 HEIGHT mm 295 650 DEPTH mm 191 298 MODEL NAME AND DIMENSIONS OUTDOOR UNIT CAUTION When heating operation drain or defrosted water f...

Страница 5: ...bout 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE OPERATION LAMP This lamp lights during operation The OPERATION LAMP flashes in the following cases during heating 1 During preheating For about 2 3 minutes after starting up 2 During defrosting Defrosting will be performed...

Страница 6: ...PERATURE buttons Use these buttons to raise or lower the temperature setting Keep pressed and the value will change more quickly TIME button Use this button to set and check the time and date RESET buttons FUNCTION selector Use this button to select the operating mode Every time you press it the mode will change from AUTO to HEAT to DEHUMIDIFY to COOL and to FAN cyclically FAN SPEED selector This ...

Страница 7: ...cessary by maximum of 3 C Press the temperature button and the temperature setting will change by 1 C each time The preset temperature and the actual room temperature may vary somewhat depending on conditions The display does not indicate the preset temperature in the AUTO mode If you change the setting the indoor unit will produce a beep 1 C RESET Press the FAN SPEED button AUTO and LOW is availa...

Страница 8: ... first and varies to MED or LOW automatically when the preset temperature has been reached HI Economical as the room will become warm quickly But you may feel a chill at the beginning MED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE buttons the display indicates the setting The temperature setting and the actual room temperature may vary somewhat depend...

Страница 9: ...he temperature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 20 26 C is recommended as the room temperature for dehumidifying Press the START STOP button Dehumidifying operation starts with a b...

Страница 10: ...ED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE button the display indicates the setting The temperature setting and the actual room temperature may vary some how depending on conditions Press the START STOP button Cooling operation starts with a beep Press the button again to stop operation The cooling function does not start if the temperature setting...

Страница 11: ... and setting temperature is large fan starts to run at HI speed After room temperature reaches the preset temperature the cooling operation which changes the fan speed and room temperature to obtain optimum conditions for natural healthful cooling will be performed For the cooling operation FAN OPERATION You can use the device simply as an air circulator Use this function to dry the interior of th...

Страница 12: ...EL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit 1 Set the current month and day with the TIMER control button 1 Press the OFF TIMER button The OFF mark blinks on the display 1 Press the ON TIMER button the ON mark blinks on the display 2 Set the turn off time with the TIMER control button Press the RESERVE button 3 Press the ON TIMER button so that ...

Страница 13: ...me with the TIMER control button The setting of turn off time is now complete Example The device will turn off at 11 00p m Example The device will turn on at 7 00 a m The setting of the turn on time is now complete 4Set the turn on time with the TIMER control button 5 Point the signal window of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting in...

Страница 14: ... 2 Press the SLEEP button and set the sleep timer The device will be turned off by the sleep timer and turned on by on timer How to Cancel Reservation Point the signal window of the remote controller toward the indoor unit and press the CANCEL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit For heating In this case the device will turn off in 2 hours a...

Страница 15: ...al air deflector within the adjusting range shown on the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes When cooling dehumidifying When heating CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop RESET Adjustment...

Страница 16: ...e old batteries 2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months CAUTION Push and pull to the direction of arrow ...

Страница 17: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and o...

Страница 18: ...ndoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Caution To avoid noise interference please place the indoor unit and its remote controller at least 1m away from electrical products Inverter type...

Страница 19: ...this condition Air cleansing filters are washable and reusable up to 20 times by using vacumm cleaner or water rinse under running tap water Type number for this air cleansing filter is SPX CFH18 Please use this number for ordering when you want to renew it Do not operate the air conditioner without filter Dust may enter the air conditioner and fault may occur Claws 4 places Attaching the air clea...

Страница 20: ... deteriorate the filter electrostatic performance PROCEDURE Open the front panel and remove the filter Gently lift and remove the air cleansing filters from the air filter frame Vacuum dust from the air filter and air cleansing filter using vacuum cleaner If there is too much dust air filter only rinse under running tap water and gently brush it with soft bristle brush Allow filters to dry in shad...

Страница 21: ... cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel Arm When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly put it out forward Attaching the Front Panel Move ...

Страница 22: ...lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by...

Страница 23: ...lowing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please co...

Страница 24: ...ly Companies are to be observed Minimum Maximum Minimum Maximum Indoor Dry bulb C 21 32 20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Cooling Heatin...