Hitachi RAC-30CH5 Скачать руководство пользователя страница 20

– 20 –

ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS

1

Open the front panel.

Pull up the front panel by holding it at both sides
with both hands.

2

Remove the filter.

Push upward to release the claws and pull out the
filter.

3

Attaching the air cleansing and deodorizing filters
to the filter.

Attach the air cleansing and deodorizing filters to
the frame by gently compress its both sides and
release after insertion into filter frame.

4

Attach the filters.

Attach the filters by ensuring that the surface written
“FRONT” is facing front.

After attaching the filters, push the front panel at
three arrow portion as shown in figure and close it.

Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

CAUTION

CAUTION

Do not bend the air cleansing
and deodorizing filter as it may
cause damage to the structure.

NOTE

In case of removing the air cleansing and deodorizing filters, please follow the above procedures.

The cooling capacity is slightly weakened and the cooling speed becomes slower when the air cleansing
and deodorizing filters are used. So, set the fan speed to "HIGH" when using it in this condition.

Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum cleaner
or water rinse under running tap water. Type number for this air cleansing filter is <SPX-CFH19>.
Please use this number for ordering when you want to renew it.

Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.

Claws

(4 places)

Содержание RAC-30CH5

Страница 1: ...R UNIT RAC 70YHA1 RAC 80YHA1 RAS 70YHA1 RAS 80YHA1 MODEL RAS 70YHA1 RAC 70YHA1 RAS 80YHA1 RAC 80YHA1 Instruction manual Page 1 26 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely SPLIT TYPE ...

Страница 2: ...or unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE PRECAUTIONS DURING OPERATION Avoid an extended period of direct air flow for your health W A R N I N G Should abnormal situation arises like burning smell please stop operating the unit and turn off the circuit breaker Contact ...

Страница 3: ... water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved Do not climb on the outdoor ...

Страница 4: ...condition Refer page 5 HORIZONTAL DEFLECTOR VERTICAL DEFLECTOR AIR OUTLET Refer page 16 REMOTE CONTROLLER Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 WIDTH mm MODEL RAS 70YHA1 RAS 80YHA1 RAC 70YHA1 RAC 80YHA1 HEIGHT mm DEPTH mm MODEL NAME AND DIMENSIONS 1150 850 333 800 245 298 DRAIN PIPE Condensed water drain to outside CONNECTING CORD AIR INLET BACK ...

Страница 5: ...en the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode OPERATION INDICATOR TIMER LAMP This lamp lights when the timer is working OPERATION LAMP This lamp lights during operation FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean...

Страница 6: ...ing Keep pressed and the value will change more quickly SLEEP button Use this button to set the sleep timer TIME button Use this button to set and check the time and date RESET buttons FUNCTION selector Use this button to select the operating mode Every time you press it the mode will change from AUTO to HEAT to DEHUMIDIFY to COOL and to FAN cyclically PARALLEL SWING button Controls the angle of t...

Страница 7: ...ons The display does not indicate the preset temperature in the AUTO mode If you change the setting the indoor unit will produce a beep 1 START STOP C Over 27 C COOL 23 27 C Under 23 C HEAT Temperature setting Function 27 C 23 C Slightly lower than the room temperature LOW FAN SPEED HI at start MED or LOW after the preset temperature is reached HI at start MED or LOW after the preset temperature i...

Страница 8: ...l become warm quickly But you may feel a chill at the beginning MED Quiet LOW More quiet Set the desired room temperature with the TEMPERATURE buttons the display indicates the setting The range of 18 22 C is recommended as the room temperature for heating If the temperature setting is 20 C the room temperature will be controlled at around 20 C The temperature setting and the actual room temperatu...

Страница 9: ...of the temperature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 20 26 C is recommended as the room temperature for dehumidifying C Press the START STOP button Dehumidifying operation starts wi...

Страница 10: ...E button the display indicates the setting The range of 25 28 C is recommended as the room temperature for cooling If the temperature setting is 27 C the room temperature will be controlled at around 27 C The temperature setting and the actual room temperature may vary somewhat depending on conditions Press the START STOP button Cooling operation starts with a beep Press the button again to stop o...

Страница 11: ...ration For the heating operation The fan speed will automatically change according to the temperature of discharged air When the difference of room temperature and setting temperature is large fan starts to run at HI speed When the room temperature reaches setting temperature fan speed changes to LOW automatically When the difference of room temperature and setting temperature is large fan starts ...

Страница 12: ...e CANCEL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit 1 Set the current month and day with the TIMER control button 1 Press the OFF TIMER button The OFF mark blinks on the display 1 Press the ON TIMER button the ON mark blinks on the display 2 Set the turn off time with the TIMER control button Press the RESERVE button 3 Press the ON TIMER button so...

Страница 13: ...now complete Example The device will turn off at 11 00p m Example The device will automatically turn on earlier so that the preset temperature can be reached at 7 00 a m The setting of the turn on time is now complete 4Set the turn on time with the TIMER control button 5 Point the signal window of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting...

Страница 14: ...roller The TIMER lamp lights with a beep from the indoor unit When the sleep timer has been set the display indicates the turn off time Example If you set 3 hours sleep time at 11 38 p m the turn off time is 2 38 a m 2 Press the SLEEP button and set the sleep timer The device will be turned off by the sleep timer and turned on by on timer How to Cancel Reservation Point the signal window of the re...

Страница 15: ...e s health You can set the sleep timer to turn off after 1 2 3 or 7 hours If date or current time is not set sleep timer can not be set If you set the sleep timer after the off on off or off on timer has been set the sleep timer becomes effective instead of the off on off or off on timer set You can not set other timer during sleep timer operation NOTE ...

Страница 16: ... The deflector can be swung up and down continuously and also set to the desired angle using the AUTO SWING button If the PARALLEL SWING button is pressed once the vertical air deflectors swing left and right to parallel If the button is pressed again the deflectors stop in their current position Several second about 6 seconds may be required before the deflectors start to move If the SYMMETRY SWI...

Страница 17: ...t the old batteries 2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months CAUTION Push and pull to the direction of arrow ...

Страница 18: ...r operation mode together with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit f...

Страница 19: ... mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Inverter type fluorescent lamp To prevent interference place at least 1m away TV Caution To avoid n...

Страница 20: ...only by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air cleansing and deodorizing filter as it may cause damage to the structure NOTE In case of removing the air cleansing and deodorizing filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when the air...

Страница 21: ...with soft bristle brush Allow filters to dry in shade 3 Re insert the air cleansing and deodorizing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filter may shrink When washin...

Страница 22: ...f the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly put it out forward Attaching the Front ...

Страница 23: ...UR SALES AGENT OR SERVICE SHOP Is the earth line disconnected or broken Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable Is the plug of power line firmly plugged into the socket Please ensure no loose contact between them Air Blow Cleaning and maintenance must be carried out only by qualified service personal Before cleaning stop operation and switch off ...

Страница 24: ...ng noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please contac...

Страница 25: ...Supply Companies are to be observed Minimum Maximum Minimum Maximum Indoor Dry bulb C 21 32 20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Cooling He...

Страница 26: ... 26 MEMO ...

Отзывы: