Troubleshooting support
Ĉ
·
The failure modes detected on the indoor and outdoor unit sides
are stored in the nonvolatile memory of the indoor unit and can be
read later on.
ǂ
(The memory will remain even after power-off.)
·
The failure modes detected on the outdoor unit side are written in
memory every time any such mode occurs. The failure mode can
therefore be detected on the indoor unit side without waiting for
the retry frequency to reach the display of the indoor unit lamp.
Moreover, the normal self-diagnosis display function which rarely
occurs will store and display failure modes that do not end up
displaying the indoor unit lamp.
ǂ
(Any such mode may be unable to be stored if indoor or outdoor
communications is in a failure.)
·
The product stores 5 last-stored failure modes.
·
There is a function for deleting memory. Once you clear the
memory and run the product for several days, you can read the
failure modes and check them, thereby detecting the less
frequent failure phenomena.
·
Failure modes can be checked by both the blinking of the lamp of
the indoor unit and the display of the remote control liquid crystal
display.
·
The failure mode detected on the outdoor unit side is displayed by
ǂ
blinking the "LD301". Detecting a failure will stop the outdoor unit
ǂ
and keep blinking the LD301 until it is restarted.
ǂ
(The communication error will persist until the communication is
ǂ
reestablished.)
Ć
The "self-diagnosis function of the communication circuit" available in our conventional models is now incorporated
as part of the normal self-diagnosis function. In the case of a failure in the communication circuit, you do not have
to conduct a special operation and the operations can be automatically divided into 3 blinking operations and 12
blinking operations of the timer lamp. However, a strong external noise may have resulted in 12 times of blinking.
Function
n
o
it
p
ir
c
s
e
D
[Display on the
outdoor unit side]
Self-diagnosis memory
44
Содержание RAC-25FXE
Страница 2: ... DANGER 2 ...
Страница 6: ...SPECIFICATIONS 3 RAC 25 35FXE RAC 50FXE 1200g 6 ...
Страница 13: ...WIRING DIAGRAM MODEL RAC 25 35F XE 13 ...
Страница 14: ...WIRING DIAGRAM RAC 50FXE L E D O M 14 ...
Страница 15: ...M基板BOM 中继端子台基板用部品 HIC基板BOM MODEL RAC 25 35F XE 15 ...
Страница 16: ...MODEL RAC 50FXE 16 ...
Страница 21: ...L N 300 330 Main parts L N C021 C022 37 5 420V 1 5 DESCRIPTION OF MAIN CIRCUIT OPERATION RAC 25 35F XE 21 ...
Страница 25: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 25 ...
Страница 26: ...6 Electric expansion valve circuit 13 14 15 16 4 3 2 1 68 67 66 65 RED 14 12 10 7 6 1 8 6 1 6 2 48 47 46 45 26 ...
Страница 27: ...2A Fuse DC300 330V 7 1 7 27 ...
Страница 28: ...2A DC300 330V 60 100 28 ...
Страница 29: ...L N 300 330 L N 50FXE 29 ...
Страница 30: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 30 ...
Страница 34: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 34 ...
Страница 35: ...6 Electric expansion valve circuit 13 14 15 16 4 3 2 1 68 67 66 65 RED 14 12 10 7 6 1 8 6 1 6 2 48 47 46 45 35 ...
Страница 36: ...2A Fuse DC300 330V 7 1 7 36 ...
Страница 37: ...2A DC300 330V 30 60 37 ...
Страница 45: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35F X E 45 ...
Страница 46: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50FXE 46 ...
Страница 60: ...JCH WH RAC 50FXE RAC 2 5FXE RAC 3 5FXE NO 0128E 60 ...