ON
OFF
OFF
OFF
350[1/min.]
ON
350[1/min.]
2'46''
2'46''
5''
Continued from No. 1
Manual cleaning
24 consecutive
hours later
Power
Operation stop key
Sleep key
Manual cleaning key
Product operation
Cleaning dr
iv
e
motor
Initialization
--> dust box
Dust box -->
initialization
Limit
switch
Initialization
side
Operation lamp
Front panel
Vertical vane
Indoor unit
Open
Closed
Open
Closed
The 30" after the cleaning has
750 [1/min.] as its upper limit.
Continued from No. 2
ON
OFF
OFF
OFF
ON
350[1/min.]
38''
38''
2'46''
2'46''
5''
2'46''
2'46''
5''
Operation diagram 2 for filter cleaning
(manual and forcible cleaning)
Forcible cleaning
Manual cleaning possible more than
5 minutes after the last cleaning and
when the product is stopped.
Operation diagram for filter cleaning 3
(timer stopped, servicing operation)
More than 20 cumulative operating hours
Automatic cleaning when
the timer is stopped
Servicing operation
Power
Operation stop key
Sleep key
Manual cleaning key
Product operation
Cleaning dr
iv
e
motor
Initialization
--> dust box
Dust box -->
initialization
Limit
switch
Initialization
side
Operation lamp
Indoor unit
Front panel
Vertical vane
Open
Closed
Open
Closed
(Lamps off)
(Lamps off)
Cleaning lamp
15 minutes
or more
Servicing position
During this period, the
cleaning wiper is cleaned.
As-Man
As-Manual cleaning held do
ual cleaning held down f
wn for 5 seconds
or 5 seconds
As-Manual cleaning held down for 5 seconds
– 142 –