OUTDOOR UNIT
●
Please mount the Outdoor unit on stable ground to prevent vibration
and increase of noise level.
●
Decide the location for piping after sorting out the different types of
pipe available.
●
When removing side cover, please pull the handle after undoing the
hook by pulling it downward.
Removal Of Air From The Pipe And Gas Leakage Inspection
Gas Leakage Inspection
Please use gas leakage detector to check if leakage
occurs at the connection of Flare nut as shown on
the right.
If gas leakage occurs, further tighten the connection
to stop leakage. (Use the detector provided for
R410A)
FINAL
ST
AGE OF INST
ALLA
TION
Insulation And Maintenance Of Pipe Connection
1
●
The connected terminals should be completely sealed with
heat insulator and then tied up with rubber strap.
●
Please tie the pipe and power line together with vinyl tape
as shown in the
fi
gure showing the installation of Indoor and
Outdoor units. Then
fi
x their position with holders.
●
To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.
●
Completely seal any gap with putty.
Installation Of Remote Controller
2
Power Source And Operation Test
3
●
The remote controller can be placed in its holder which is
fi
xed on wall or beam.
●
To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be
fi
xed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the
fl
uorescent light. Therefore,
during the installation of the remote control holder, please
switch on the light, even during day time, to determine the
mounting location of the holder.
Power Source
CAUTION
!
●
Please use a new socket. Accident may occur due to the use
of old socket because of poor contact.
●
Please plug in and then remove the plug for 2 – 3 times. This
is to ensure that the plug is completely plugged into the socket.
●
Keep additional length for the power cord and do not render
the plug under external force as this may cause poor contact.
●
Do not
fi
x the power cord with U-shape nail.
Operation Test
●
Please ensure that the air conditioner is in normal operating
condition during the operation test.
●
Explain to your customer the proper operation procedures
as described in the user’s manual.
<
IA1122: A
>
The controller must
be hooked onto the
hook at the lower
part of the holder.
Push in the remote
controller in the
direction as shown
in
fi
gure beside.
3
Procedures of using Vacuum Pump for Air Removal
As shown in right
fi
gure, remove the cap
of valve core. Then, connect the charge
hose. Remove the cap of valve head.
Connect the vacuum pump adapter to the
vacuum pump and connect the charge
hose to the adapter.
Fully tighten the “Hi” shuttle of the
manifold valve and completely unscrew
the “Lo” shuttle. Run the vacuum pump
for about 10–15 minutes, then completely
tighten the “Lo” shuttle and switch off the
vacuum pump.
2
Completely unscrew the spindle of
the service valve (at 2 places) in anti-
clockwise direction to allow the
fl
ow of
coolant (using Hexagonal Wrench key).
3
Remove the charge hose and tighten
the cap of valve head. Check the cap’s
periphery if there is any gas leakage.
The task is then completed.
4
1
Preparation of Pipe
1
●
Use a pipe cutter to cut the copper pipe.
●
Jagged edge will cause leakage.
●
Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
●
Before
fl
aring, please put on the
fl
are nut.
Pipe Connection
2
INST
ALLA
TION OF REFRIGERA
TING PIPES
AND
AIR REMOV
AL
CAUTION
!
Outer
Diameter (mm)
6.35
9.52
12.7
For R410A tool
0.0
~
0.5mm
0.0
~
0.5mm
0.0
~
0.5mm
For R22 tool
A (mm)
AIR REMOV
AL
WARNING
●
The naked part of the wire core should be 10 mm and
fi
x it to the terminal tightly. Then try to pull the individual
wire to check if the contact is tight. Improper insertion
may burn the terminal.
●
Be sure to use only power cables approved from the
authorities in your country. For example in Germany:
Cable type: NYM 3x1.5mm
2
(Fuse = 16A time delay).
●
Please refer to the installation manual for wire connection
to the terminals of the units. The cabling must meet the
standards of electrical installation.
●
There is a AC voltage of 220-230V between the L and N
terminals. Therefore, before servicing, be sure to remove
the plug from the AC outlet or switch off the main switch.
Checking for the electric source
and the voltage range
●
Before installation, the power source must be checked and
necessary wiring work must be completed. To make the wiring
capacity proper, use the wire gauges list below for the lead-in
from a pole transformer and for the wiring from a switch board
of fuse box to the outlet in consideration of the locked rotor
current.
●
Investigate the power supply capacity and other electrical
conditions at the installation location.
Depending on the model of room air conditioner to be
installed, request the customer to make arrangements
for the necessary electrical work etc.
The electrical work includes the wiring work up the
outlet. In localities where electrical conditions are poor,
use of a voltage regulation is recommended.
●
Install outlet for the room air conditioner within the
reaching range of the line cord.
IMPORTANT
Cable length
up to
1
6m
up to 15m
up to 25m
Wire cross-section
1.5mm
2
2.5mm
2
4.0mm
2
IMPORTANT
●
THIS APPLIANCE MUST
BE EARTHED.
Procedures of Wiring
!
WARNING
!
CONNECTION OF POWER CORD
WARNING
!
Please face this side (suction
side) of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Pull downward
●
Recommend to use
R410A
fl
aring tool.
CAUTION
!
In case of removing
fl
are nut of an Indoor unit,
fi
rst remove a nut
of small diameter side, or a seal cap of big diameter side will
fl
y
out. Prevent water from entering into the piping when working.
When the meter reaches - 101KPa
(-76cmHg) during pumping, fully
tighten the shuttle.
Meter showing pressure
When pumping starts, slightly loosen the
fl
are nut to check of air sucked in. Then
tighten the
fl
are nut.
Earth terminal
N
L
C D
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
There are holes on the base of Outdoor unit for condensed
water to exhaust.
In order to
fl
ow condensed water to the drain, the unit is installed on a
stand or a block so that the unit is 100mm above the ground as shown
fi
gure. Join the drain pipe to one hole.
At
fi
rst insert one portion of the hook to the base (Portion A), then pull the
drain pipe in the direction shown by the arrow while inserting the hook
into the base. After installation, check whether the drain pipe cling to the
base
fi
rmly.
When Using and Installing In Cold Areas
When the air conditioner is used in low temperature and in snowy
conditions, water from the heat exchanger may freeze on the base surface
to cause poor drainage. When using the air conditioner in such areas, do
not install the bushings. Keep a minimum of 250mm between the drain
hole and the ground. When using the drain pipe, consult your sales agent.
For more details, refer to the installation Manual for Cold Areas.
A
1.0mm
1.0mm
1.0mm
Lo
Hi
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove
front panel and electrical cover.
Method to remove front panel
●
Refer to “FINAL STAGE OF INSTALLATION – How to Remove
The Front Cover”.
Outer
dia.of pipe
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
Valve
head cap
Torque N·m
(kgf
·
cm)
13.7 – 18.6 (140 – 190)
34.3 – 44.1 (350 – 450)
44.1 – 53.9 (450 – 550)
19.6 – 24.5 (200 ~ 250)
19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 – 350)
12.3 – 15.7 (125 ~ 160)
Small dia. side
Large dia. side
Valve core cap
Small dia. side
Large dia. side
Power supply shall be connected at the rated voltage, otherwise
the unit will be broken or could not reach the speci
fi
ed capacity.
Outdoor Unit
GRN + YEL
Strip wires
Power line
Control line
GRN + YEL
Strip wires
Indoor Unit
Detail of cutting the
connecting cord
When removing the
connecting wires for
the Indoor unit, please
remove the low cover
panel in front of the
unit.
●
If you cannot attach the side plate due
to the connecting cord, please press the
connecting cord in direction to the front
panel to
fi
x it.
●
Be sure that the hooks of the side plate is
fi
xed in certainly. Otherwise water leakage
may occur and this causes short circuit or
faults.
●
The connecting cord should not touch to
service valve and pipes. (It becomes high
temperature in heating operation.)
Wiring of The Outdoor Unit
●
Please remove the side plate for wire connection.
Fuse Capacity
16A time delay fuse
How to Remove The Front Cover
1 Remove the front panel.
●
Please remove and attach the front panel by both hands.
●
After opening the front panel by both hands.
➀
Undo the right arm while pushing it inside.
➁
Slide the front panel to right as shown in
fi
gure. Then
remove while pulling it to front.
2 Remove the
fi
lters.
3 After removing two screws, pull the center of the front
cover towards you and release the claws.
4 Pull the side faces (lower sections) of the front cover
towards you as shown in the
fi
gure and remove the
cover.
How to Attach the Front Cover
1
Check that the drain pan is securely attached.
2 After installing the front cover onto the unit, hook three
claws at upper side of the cover securely. Then, push
the center of the front cover to lock the claws.
3
Tighten the two screws.
4 Install
the
fi
lter.
5
Slide the shafts of the right and left arms on the washable
panel along the steps to insert the shafts into the holes
till they stop. After checking that the shafts are securely
inserted, close the panel.
Method to remove the low cover
●
Pull the cover at 1 and 2
in the directions as shown by
arrows to remove the cover.
After remove the screw
and cover, and put the
connecting cords and
fi
x
the cover with screw.
DRAIN PIPE
[For all optional part, please refer catalog for part number]
As for connecting to H-Link, a separately purchased
RAC Adapter is required.
●
To install the wiring the electrical box cover must be opened.
●
Connect the connector of RAC adapter to CN7.
●
Assemble back the cover of electrical box.
●
Please refer to the respective user manual of RAC Adapter
for further details.
●
Please be careful not to damage lead wires by edge of
plate when connecting the optional parts.
[For all optional part, please refer catalog for part number]
Connection to the electrical box:
●
Remove the cover of electrical box.
●
Connect the connector of Weekly Timer/wired remote
controller to CN9.
●
Assemble back the cover of electrical box.
●
Please refer to the respective user manual of Weekly Timer/
wired remote controller for further details.
●
Please be careful not to damage lead wires by edge of
plate when connecting the optional parts.
WEEKLY TIMER / WIRED REMOTE CONTROLLER
H-LINK
How To Connect The Optional Parts
(RAC Adapter, Weekly Timer, Wired Remote Control)
CN7
RAC Adapter
cord
CN9
Weekly timer cord/
Wired remote
controller cord
Connect the
earth cord
Closed
R410A
Manifold valve
Valve
Charge hose
Valve
Vacuum pump
adapter
Vacuum
pump
BASE