[Situation]
The product is giving a display to indicate that it is performing forcible cooling.
(This is not a sign of a breakdown.)
[Estimated failure locations]
·
Meltdown of the terminal board temperature fuse (the terminal board poorly inserted into
the F cable)
·
Outdoor communication circuit out of order
[Cautions]
[Diagnosis flow]
[Situation]
The timer lamp blinks three times and the product will not operate.
·
If a terminal board is replaced to counter the meltdown of the terminal board temperature
fuse, ensure that the F cable to be inserted into the terminal board has the appropriate
dimension for peeling the insulation sheathing and that the insertion region is unbent before
inserting it into the terminal board securely.
Detach the connector (CN3) from the terminal board
temperature fuse and check the temperature fuse for
continuity. Is the resistance almost 0
No
Yes
Initiating troubleshooting
Replace the "indoor electrical parts".
Replace the "terminal board".
6. Timer lamp blinking: blinking twice
7. Timer lamp blinking: blinking three times
[Estimated failure locations]
·
Outdoor unit error.
·
Please confirm the times of the LD301 blinking, and then
Situation
The timer lamp blinks four times and the product will not operate.
see the outdoor selfcheck lable.
[Situation]
(This is not a sign of a breakdown.)
5. Timer lamp blinking: blinking once
The timer lamp blinks one time and the product will not operate.
[Estimated failure locations]
·
Reversing valve defective.
·
The refrigerating cycle block gas leak.
8. Timer lamp blinking: blinking four times
Содержание RAC-10WECI
Страница 2: ... DANGER ...
Страница 9: ... ...
Страница 10: ... ...
Страница 11: ... ...
Страница 13: ... ...
Страница 14: ... ...
Страница 15: ... ...
Страница 26: ...MODEL RA C 18 25 35 W EC RAC 10 14WECI ...
Страница 27: ...MODEL RAC 50WEC RAC 20WECI ...
Страница 39: ... MODEL RAK 18 25PEC RAK 25PECC RAK 10PECI RAC 18 25WEC RAC 10WECI 5KNGPEGT 5KNGPEGT 5KNGPEGT 5KNGPEGT ...
Страница 40: ... MODEL RAK 35PEC RAK 14PECI RAC 35WEC RAC 14WECI 5KNGPEGT 5KNGPEGT 5KNGPEGT 5KNGPEGT RAK 35PECC ...
Страница 41: ... MODEL RAK 50PEC RAK 20PECI RAC 50WEC RAC 20WECI 1 2 1 2 1 2 1 2 RAK 50PECC ...
Страница 50: ...10 10 10 10 10 R901 R904 R641 R907 R908 R694 R902 R695 R741 R740 R642 DSW1 DSW1 R903 R905 R906 ...
Страница 53: ...L N 300 330 Main parts C021 C022 375 420V L N 15 MODEL RAC 18 25 35WEC RAC 10 14WECI ...
Страница 57: ...5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 ...
Страница 58: ...6 Electric expansion valve circuit 48 47 46 45 13 14 15 16 4 3 2 1 68 67 66 65 RED 14 12 10 7 6 1 8 6 1 6 2 ...
Страница 59: ...2A Fuse DC300 330V 7 7 1 ...
Страница 60: ...2A DC300 330V ...
Страница 61: ...L N 300 330 L N MODEL RAC 50WEC RAC 20WECI ...
Страница 62: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 ...
Страница 66: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 ...
Страница 67: ...6 Electric expansion valve circuit 5 13 14 15 16 4 3 2 1 68 67 66 65 RED 14 12 10 7 6 1 8 6 1 6 2 22 23 24 2 ...
Страница 68: ...2A Fuse DC300 330V 7 1 7 ...
Страница 69: ...2A DC300 330V ...
Страница 79: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 18 25 35WEC RAC 10 14WECI ...
Страница 80: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50WEC RAC 20WECI ...