Operation
mode
Control function
Fan
Cooling
Sensor dehumidi
fi
cation
Heating
Automatic
1
Start/stop button,
basic mode
2
Timer
operation
ON timer
OFF timer
OFF
→
ON
timer
Automatic
MED
LO
HI
●
Operation in the previous
circulation
mode
●
Operation in “HI” mode
●
Operation in “MED” mode
●
Operation in “LO” mode
●
Same as on the left.
●
Same as on the left.
●
Same as on the left.
●
Only circulation
with cut velocity is
executed, independent
of the thermostat
signal.
(1) Strong
3
Circulation
mode
Thermostat operation
H
→
HI
L
→
MED
S
→
LO
●
The power relay is
delayed by 2 seconds
from the start of
thermostat operation.
(1) In case of “Automatic” mode
Note:
●
The min. ON time of the power relay
is 3 minutes, and the min. OFF time
also is 3 minutes.
(2)
In other modes than “Automatic”
Same as above (but operation is
made with the velocity set at the
time of operation start).
●
“HI”, “MED”, or “LO” operation is
executed according to the thermostat
signal. (Refer to “Thermostat operation”.)
→
●
“LO” and “Stop” are repeated according to the thermostat
signal, independent of the setting.
Notes:
●
Forced operation by start/stop
button ON is executed even
with thermostat OFF.
●
The room temperature 30 sec
after operation start, minus
0.66 deg, becomes the set
temperature.
●
When the room temperature
is 16°C or lower, 16°C
becomes the set temperature.
●
The other operations are the
same as for (1).
Air-blow
mode
(A)
(B)
H
L
H
L
L
L
S
S
L
Automatic
L
XL
●
“HI”, “MED”, “LO”, and “Stop” are repeated according to the thermostat
signal and time.
●
“HI”, “MED”, “LO”, and “Stop” are repeated according to the thermostat
signal and time.
●
“MED”, “LO”, and “Stop” are repeated according to the thermostat signal
and time.
●
“LO” and “Stop” are repeated according to the thermostat signal and time.
●
The “Automatic” speed mode
for each operation mode is used
independent of the setting.
(“Weak” at the time of “Sensor
dehumidi
fi
cation”.)
●
The operation mode at the
start of operation differs as
shown below according to
the room temperature.
●
A shift is not accepted at the
time of operation start.
●
There is no switching between
modes after start of operation.
●
When the operation is started
again within 20 min. after
stop with the start/stop button,
operation will be executed in
the previous mode.
●
The operation details are the
same as for each operation mode.
●
The set temperature is set with
the room temperature
adjustment button. Correction
by ,±3°C is possible with.
At this time, the operation mode
judgement temperature also is
shifted at the same time.
However, correction is possible
only in cooling operation mode,
but not in “Sensor dehumidi
fi
ca-
tion”
mode.
(2) Set temperature is higher than room temperature.
(1) When the set temperature is lower than the room
temperature.
Example for “HI” circulation mode
4
NOTES:
●
The min. ON time of the power relay is 3 minutes, and the min. OFF time
also is 3 minutes.
●
IN AUTOMATIC CIRCULATION MODE, “HI” IN SECTION (B) OCCURS ONLY
THE
FIRST
TIME.
BASIC MODE
MODEL RAS-08LH2/10LH2/14LH2 / RAS-08LH2(B)/10LH2(B)/14LH2(B) // RAC-08LH1/10LH1/14LH1
●
The min. ON time of the power relay is 3 minutes, and the
min. OFF time also is 3 minutes.
●
The indoor fan is not delayed with operation start by start/
stop button ON.
●
The indoor fan is delayed by 5 sec with operation start
by thermostat operation.
Cooling
The set temperature
shall be 27°C.
Sensor
The set temperature
dehumidi- shall be 2 degrees
fi
cation
below the room
temperature at the
start of operation.
Heating
The set temperature
shall be 23°C +
temperature shift
amount.
No.
5
6
Reversing valve lock protection
AIR BLOW CHANGE TO "H" FORCILY WHEN ENTERING "PD CUT 2"
AIR BLOW CAN BE CHANGED BY REMOTE CONTROL AFTER TEMP. T
7
.
AIR BLOW RETURNS TO THE SET SPEED AT T
5
.
●
All relays are stopped by
low-temperature input.
●
Not accepted during hot
keep, during compressor
stop, during defrosting and
during forced 3 minutes.
●
Accepted only during heating
operation.
●
Recovery at the time of stop
by low-temperature input is
reset recovery.
●
The timer lamp
fl
ashes at the
time of stop.
– 43 –
Heating load reduction and Pd cut
Room temperature
at the start of
operation
➜
➜
Содержание RAC-08LH1
Страница 33: ... 31 MODEL RAC 08LH1 RAC 10LH1 RAC 14LH1 ...
Страница 36: ... 34 WIRING DIAGRAM MODEL RAS 08LH2 10LH2 RAS 08LH2 B 10LH2 B RAC 08 10LH1 RAS 63CHA1 RAC 63CHA1 ...
Страница 37: ... 35 WIRING DIAGRAM MODEL RAS 14LH2 14LH2 B RAC 14LH1 RAS 63CHA1 RAC 63CHA1 ...
Страница 40: ... 41 BLOCK DIAGRAM MODEL RAS 08LH2 10LH2 14LH2 RAS 08LH2 B 10LH2 B 14LH2 B RAC 08LH1 10LH1 14LH1 ...
Страница 44: ... 48 REFRIGERANT CYCLE DIAGRAM MODEL RAS 08LH2 RAS 08LH2 B RAC 08LH1 MODEL RAS 10LH2 RAS 10LH2 B RAC 10LH1 ...
Страница 45: ... 49 MODEL RAS 14LH2 RAS 14LH2 B RAC 14LH1 ...
Страница 53: ... 57 ...
Страница 64: ... 68 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 08LH2 RAS 10LH2 RAS 14LH2 RAS 08LH2 B RAS 10LH2 B RAS 14LH2 B ...
Страница 71: ... 75 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 08LH1 ...
Страница 73: ... 77 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10LH1 RAC 14LH1 ...