MODEL RAS-08CH9/RAS-08CH9(B) / RAC-08CH9 and RAS-10CH9/RAS-10CH9(B) / RAC-10CH9
Figure showing the installation of Indoor and Outdoor unit
The installation height of indoor unit must be 2.3m or more in a non public area
CAUTION
!
– 5a –
above 50mm
above 100mm
above
0.45m
above 300mm
must not bend
above 100mm
2,300mm or more
1
2
Maximum pipe length 10m
Minimum pipe length 5m
Plug
above 100mm
❈
above 300mm
above 200mm
❈
above 100mm
❈
give clearance
as wide as
possible
above 50mm when
installed on the
ceiling of balcony
above 200mm
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
●
The difference in height
between the indoor and
outdoor unit should be kept
max 5m.
●
The connecting pipe, no
matter big or small, should
all be insulated with
insulation pipe and then
wrapped with vinyl tape.
(The insulator will
deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
inner diameter ø 16mm