background image

SAFETY PRECAUTION

 

Read the safety precautions carefully before operating the unit.

The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

WARNING ........ Incorrect methods of installation may cause death or serious injury.

CAUTION ......... Improper installation may result in serious consequence.

The sign in the 

fi

 gure indicates prohibition.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit 
as described in the user’s manual.

!
!

WINDOW  TYPE  ROOM  AIR  CONDITIONER 
OPERATION  AND  INSTALLATION  MANUAL

PRECAUTIONS DURING INSTALLATION

Please ask sales agent or quali

fi

 ed technician for the installation of the unit. Water leakage,

short circuit or 

fi

 re may occur if install the unit improperly.

Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line
of telephone. Improper installation of earth line may cause electric shock.

A circuit breaker should be installed depending on the mounting site of the unit. Without
a circuit breaker, the danger of electric shock exists.

Do not install near location where there is 

fl

 ammable gas. The unit may catch 

fi

 re  if 

fl

 ammable gas leaks around it.

If drain pan is used, please ensure that when installing the drain hose, water is able to

fl

 ow freely without any obstruction.

CAUTION

!

!

WARNING

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

If abnormal situation arises (like burning smell), please stop the unit and turn off the
circuit breaker. Fault, short circuit or 

fi

 re may occur if the unit is continue to operate under 

abnormal situation.

 

Please contact your agent for maintenance. Improper maintenance may cause electric
shock and 

fi

 re.

 

Please contact your agent if need to remove and reinstall the unit. Electric shock or 

fi

 re 

may occur if you remove and reinstall the unit improperly.

WARNING

!

PARTS IDENTIFICATION AND OPERATIONS

1

 Cabinet

2

 Suction 

Grille

3

 Front 

Cover

4

 Horizontal 

De

fl

 ectors

5

 Vertical 

De

fl

 ector 

6

  Air Exhaust Lever

7

  Switch Panel Cover

Model

RA-08MDF / RA-08MEDF
RA-10MDF / RA-10MEDF

RA-13MDF / RA-13MEDF

Width

18 

1

2

”, 470mm

22 

3

64

”, 560mm

Height

13 

1

2

”, 345mm

14 

3

4

”, 375mm

Depth

25 

3

16

”, 640mm

27 

29

32

”, 709mm

CONTROL PANEL

INDICATION LAMP

TEMPORARY SWITCH

Use the temporary switch for start or stop operation when operation cannot be done with the remote controller.

By pressing the temporary switch, [use non-conductor stick (for example: toothpick),] the operation will follow previous  
operation mode.

When the operation is done using the temporary switch, after the power source is turned off and is turned on again, the 
operation is done in automatic mode.

AIR DEFLECTORS

Vertical de

fl

 ectors at both sides of outlets can be set to 

either auto-swing or static position to direct discharge air 
rightward, leftward or forward direction.

Horizontal de

fl

 ectors at both sides of the outlets can 

be set to direct discharge air upward, downward or 
forward direction.

VERTICAL DEFLECTORS

HORIZONTAL DEFLECTORS

To avoid dew forming on the de

fl

 ectors which eventually may drip to the 

fl

 oor, please do not adjust horizontal de

fl

 ectors 

extremely downward position or vertical de

fl

 ectors extremely leftward or rightward position during cool operation for a long 

time.
Also, do not adjust the vertical de

fl

 ectors position by hand or any other object.

!

CAUTIONS

AIR EXHAUST LEVER

WASABI AIR PURIFYING FILTER

Set the air exhaust lever to the down ( OPEN) position for air ventilation in 
the room. The air exhaust lever should normally be kept in up ( CLOSE) 
position during cooling operation and in the case of typhoon.

NOTES ON OPERATION

TEMPERATURE AND HUMIDITY

Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended 
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form 
on the outlet grille and de

fl

 ectors of the unit.

NOISE

In a quiet environment during the starting or stopping the operation, phenomena like 

fl

 owing sound of refrigerant in the 

refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and 
blown onto the condenser coil, this creates a “splashing” sound which is normal.

ODOR

The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high 
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs, 
cosmetics and others which may stick to the room air conditioner. So, the pre-

fi

 lter and the evaporator regularly must be 

cleaned to reduce the odor.

THE IDEAL WAYS OF OPERATION

Suitable Ro

om

 Temperature

 

   

Warning

Freezing temperature 
is bad for health and a 
waste of electric power.

!

Install curtain or blinds

It is possible 
to reduce heat 
entering the room 
through windows.

Ventilation

   

Caution

Do not close the room for a long period of 
time. Occasionally 
open the door and 
windows to allow the 
entrance of fresh air.

!

Do Not Forget To Clean The Pre-Filter

Dusty pre-

fi

 lter will reduce the air 

volume and the cooling ef

fi

 ciency. 

To prevent from wasting electric 
energy, please clean the pre-

fi

 lter 

every 20 days.

Please Adjust Suitable Temperature 

For Baby And Children

Please pay attention to the 
room temperature and air 

fl

 ow 

direction when operating the 
unit for baby, children and old 
people who have dif

fi

 culty in 

movement.

FOR USER’S INFORMATION

The Air Conditioner And The Heat Source In The Room

    Caution

If the amount of heat in the room is above the cooling capability of the air conditioner (for 
example: more people entering the room, using heating equipments and etc.), the preset 
room temperature cannot be achieved.

!

When Lightning Occurs

   Warning

To protect the unit during lightning, please stop operating the unit and remove the plug 
from the socket.

!

<

IA0000: A 

>

TEMPORARY SWITCH
Use this switch to start operation and stop 
when the remote controller does not work. 
Normally do not use this switch

POWER SWITCH

DEHUMIDIFY LAMP

OPERATION LAMP

TIMER LAMP

1. Pull and remove the suction grille

2. Remove the pre-

fi

 lter

3.  Install  the  wasabi  air  purifying 

fi

 lter in the frame

4. Install back the pre-

fi

 lter  and 

close the suction grille

Always stop the operation before installing the wasabi air purifying 

fi

 lter.

Wasabi air purifying 

fi

 lter are not washable. It is recommended to use vacuum to clean it. It can be used use for 1 year 

time. Type number for this  wasabi air purifying 

fi

 lter is <SPX-CFH9W>. Please use this number for ordering when you 

want to renew it.

MODEL

RA-08MDF / RA-08MEDF
RA-10MDF / RA-10MEDF
RA-13MDF / RA-13MEDF

Содержание RA-08MDF

Страница 1: ... not adjust the vertical deflectors position by hand or any other object CAUTIONS AIR EXHAUST LEVER WASABI AIR PURIFYING FILTER Set the air exhaust lever to the down OPEN position for air ventilation in the room The air exhaust lever should normally be kept in up CLOSE position during cooling operation and in the case of typhoon NOTES ON OPERATION TEMPERATURE AND HUMIDITY Avoid to use the room air...

Страница 2: ...t dry cloth When it is excessively dirty wipe it with a soft cloth dampened with mild soap then wipe it again thoroughly with a soft dry cloth The suction grille can also be removed and be washed with water and mild soap Remove the suction grille in the following manner 1 Remove the suction grille by pulling the bottom corner and slightly lift up the suction grille 2 3 Pull downward to unhook the ...

Страница 3: ...operation RESET button STOP button Press this button to stop the operation SLEEP TIMER button Press this button to set the sleep timer FAN SPEED button Press this button to change the fan speed Every time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW AUTO SWING button Press this button to set auto swing or stop angle of the vertical air deflector TEMP...

Страница 4: ...ller you only have to press the COOLING button next time 1 2 STOP 3 Dehumidifying Function When the room temperature is higher than the temperature setting The device will start to dehumidify and lower the room temperature to the preset level When the room temperature is lower than the temperature setting Dehumidifying will be performed at the temperature setting slightly lower than the current ro...

Страница 5: ...rking for the designated number of hours and then turn off Point the signal window of the remote controller toward the indoor unit and press the SLEEP TIMER button The timer information will be displayed on the remote controller The TIMER lamp lights with a beep from the indoor unit SLEEP TIMER Mode SLEEP TIMER 4 4 4 1 Indication 1 hr 2 hrs 3 hrs 10 hrs 11 hrs 12 hrs Cancel sleep timer 4 4 After s...

Страница 6: ...t use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 months or longer 3 Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages When using the remote controller if there is no response from the air conditioner or the remote controller display is dim please try...

Страница 7: ... IA0000 A RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF ...

Страница 8: ...0 A RA 13MDF RA 13MEDF ࡌ ઠ ྫ ປ ሣ ૃ ጠ ᘞ Ă ቜ ϵ ཆ ϱ ა ݣ ቜ շ ັ Ӱ ྫ ປ ሣ Ё Ą 20mm ʰ 20mm ʰ RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF 15Њઉ ᔞ ዢ ...

Страница 9: ... 1 ଂ ...

Страница 10: ... 2 ...

Страница 11: ... 3 ...

Страница 12: ... 4 IA0000 A ...

Отзывы: