7
INSPECTION AND MAINTENANCE
CAUTION
Be sure to disconnect the hose during cleaning
jams, inspection, maintenance and cleaning.
1. Inspecting the magazine
1
DISCONNECT AIR HOSE.
2
Clean the magazine. Remove paper chips or wooden
chips which may have accumulated in the magazine.
Lubricate it with Hitachi pneumatic tool lubricant.
2. Check on mounting screws for each part
At regular intervals check every part for loose mounting
screws and whether or not there are any air leaks.
Retighten any loose screws. Operating the equipment
with loose screws untightened will incur a hazard.
3. Inspecting the push lever
Check if the push lever can slide smoothly.
Clean up the sliding area of the push lever and use the
provided oil for lubrication from time to time.
Lubrication enables smooth sliding and simultaneously
serves to prevent the formation of rust.
4. Storing
䡬
When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
䡬
Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
䡬
When not in use, the Nailer should be stored in a warm
and dry place.
Keep out of reach of children.
5. Service parts list
CAUTION
Repair, modification and inspection of Hitachi Power
Tools must be carried out by an Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATIONS
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
COMPRESSOR
CAUTION
When the maximum, operating pressure of the air
compressor exceeds 8.3 bar (120 psi.), be sure to
provide a reducing valve between the air compressor
and nailer. Then, adjust the air pressure within the
operating range of 4.9 – 8.3 bar (70 – 120 psi.). If the
air set is installed, lubrication is also possible, thus
providing additional convenience.
OILER-FILTER-REDUCING VALVE (Air Set)
So that the equipment can be operated under an optimum
condition to ensure extended service life, it is
recommended to use an oiler filter reducing valve. Please
limit the length of the hose between the unit and the air
set to within 10 m when using (See
Fig. 6
).
APPLICABLE LUBRICANTS
Type of lubricant
Name of lubricant
Recommended oil
SHELL TONNA
Motor oil
SAE10W, SAE20W
Turbine oil
ISO VG32 – 68
(#90 – #180)
Fig. 6
Nailer
side
Compressor
side
Reducing valve
Oiler
Filter
01Eng_NR90AD_Eng
27/6/07, 11:49
7