![Hitachi N342555809 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/hitachi/n342555809/n342555809_installation-operation-and-maintenance_145400014.webp)
PV-250 Track Relay
Copyright 2019 SM 4574F, Rev. 4, March 2019
2-4
Figure 2-2 - Receptacle Contact Springs Installed
2.4.3. Installing Wires in Receptacle Contact Springs
Use the following procedure to ensure a good electrical and mechanical connection
between the conductor wire and the receptacle contact spring. Table 2-1 identifies the
correct crimping tool to be used when installing wires in a receptacle contact spring.
Table 2-1. Crimping Tools
AMP
Crimping
Tool PN
Wire Size
Old-Style Receptacle
Contact Spring
Improved Base Receptacle Contact
Spring
J397138
#10 / #12 AWG
J680181
M451142-2703
J397139
#14 / #16 AWG
J680165 (Standard)
M451142-2702
J397188
#18 / #20 AWG
J680179
M451142-2701
1. Strip 3/16 in. (0.187 in. or 0.47 cm.) of insulation from the end of the wire.
2. Place the receptacle contact spring into the jaws of the proper crimping tool.
When using only one terminal, of any wire size, use the shortest terminal.
3. Partially close the crimping tool jaws against the receptacle contact spring to hold
it in place. (Do not crush the receptacle contact spring barrel at this time.)
4. Insert the stripped end of wire all the way into the receptacle contact spring
barrel. Squeeze the tool handles until crimping is completed and the jaws
release. When using both terminals, it is more convenient to attach the first wire
to the longest terminal.
Содержание N342555809
Страница 2: ...PV 250 Track Relay Copyright 2019 SM 4574F Rev 4 March 2019 ...
Страница 8: ...PV 250 Track Relay Copyright 2019 SM 4574F Rev 4 March 2019 vi ...
Страница 16: ...PV 250 Track Relay Copyright 2019 SM 4574F Rev 4 March 2019 2 6 ...
Страница 35: ...PV 250 Track Relay Copyright 2019 SM 4574F Rev 4 March 2019 3 19 ...
Страница 36: ......
Страница 46: ...PV 250 Track Relay Copyright 2019 SM 4574F Rev 4 March 2019 5 2 End of Manual ...